EFFECT OF SAMPLING SITE ON FEMORAL VENOUS-BLOOD GAS VALUES

被引:14
|
作者
AGUSTI, AGN
ROCA, J
BARBERA, JA
CASADEMONT, J
RODRIGUEZROISIN, R
WAGNER, PD
机构
[1] UNIV BARCELONA,HOSP CLIN BARCELONA,SERV PNEUMOL,E-08036 BARCELONA,SPAIN
[2] UNIV BARCELONA,HOSP CLIN BARCELONA,SERV ALLERGIA RESP,E-08036 BARCELONA,SPAIN
[3] UNIV CALIF SAN DIEGO,PHYSIOL SECT,LA JOLLA,CA 92093
关键词
BLOOD GAS MEASUREMENTS; EXERCISE; FEMORAL VENOUS OXYGEN PARTIAL PRESSURE; OXYGEN TRANSPORT; OXYGEN UPTAKE; VARIABILITY;
D O I
10.1152/jappl.1994.77.4.2018
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
To examine whether the tip of the femoral vein catheter used for sampling femoral venous PO2 during cycling exercise is contaminated by skin or saphenous vein blood, we studied 6 healthy volunteers [21.7 +/- 0.7 (SD) yr] during three identical incremental exercise tests while breathing room air on the same day. Femoral venous blood was sampled simultaneously from two catheters inserted into the femoral vein but advanced in opposite directions (7 cm distally and 5 cm proximally). Blood sampling for measurements of PO2, PCO2, pH, hemoglobin concentration, and oxyhemoglobin saturation was done simultaneously from both catheters in duplicate at rest, at 60% of maximum workload (60% W), and at maximum symptomlimited exercise (100% W). Temperature was measured with a thermistor probe placed in the proximal catheter. At rest, distal PO2 was significantly lower than that measured proximally (24.9 +/- 4.3 vs 30.8 +/- 6.1 mmHg, respectively; P < 0.004), but no differences were found during exercise (60% W, 23.6 +/- 3.4 vs. 24.5 +/- 3.6 mmHg; 100% W, 26.0 +/- 3.6 vs. 25.5 +/- 2.8 mmHg, respectively). Comparison of blood temperatures between proximal and distal sites of sampling in two subjects showed negligible differences. Intrasubject coefficient of variation of distal femoral venous PO2 over the three bouts of exercise was 11.5% (2.9 mmHg) at rest, 5.9% (1.4 mmHg) at 60% W, and 5.6% (1.5 mmHg) at 100% W. Mean differences in distal PO2 between duplicate samples were 0.5 +/- 1.4 mmHg at rest, 0.1 +/- 0.8 mmHg at 60% W, and 0.6 +/- 0.9 mmHg at 100% W. We conclude that the site of femoral venous sampling may influence the analysis of muscle O-2 transport at rest but not at greater than or equal to 60% maximal O-2 uptake, suggesting negligible contributions to O-2 indexes from nonexercising tissues under these conditions.
引用
收藏
页码:2018 / 2022
页数:5
相关论文
共 50 条
  • [21] CONVENIENT AND RELIABLE METHOD FOR REPEATED VENOUS-BLOOD SAMPLING IN MAN
    OH, TE
    ILETT, KF
    JELLETT, LB
    BRITISH JOURNAL OF CLINICAL PHARMACOLOGY, 1976, 3 (05) : 939 - 939
  • [22] COMPARISON OF CONVENTIONAL BLOOD-GAS ANALYSIS AND AN ON-DEMAND BEDSIDE BLOOD-GAS MONITOR IN THE DETERMINATION OF MIXED VENOUS-BLOOD GAS VALUES
    PERUZZI, WT
    FRANKLIN, ML
    SHAPIRO, BA
    MOEN, SG
    ANESTHESIOLOGY, 1994, 81 (3A) : A620 - A620
  • [23] ARTERIAL AND VENOUS-BLOOD SAMPLING IN PHARMACOKINETIC STUDIES - AZOSEMIDE IN RABBITS
    LEE, SH
    SHIN, WG
    LEE, MG
    KIM, ND
    BIOPHARMACEUTICS & DRUG DISPOSITION, 1994, 15 (04) : 305 - 316
  • [24] CHRONIC CATHETERIZATION FOR SAMPLING VENOUS-BLOOD FROM BRAIN OF SHEEP
    HALES, JRS
    PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1972, 337 (01): : 81 - &
  • [25] COMPARISON OF CAPILLARY AND VENOUS-BLOOD SAMPLING FOR QUANTITATION OF PLASMA CHOLESTEROL
    ISHIKAWA, T
    MORRISON, J
    FALLAT, R
    PARSONS, D
    TSANG, R
    GLUECK, CJ
    PEDIATRIC RESEARCH, 1974, 8 (04) : 434 - 434
  • [26] CAN CENTRAL VENOUS-BLOOD REPLACE MIXED VENOUS-BLOOD SAMPLES
    TAHVANAINEN, J
    MERETOJA, O
    NIKKI, P
    CRITICAL CARE MEDICINE, 1982, 10 (11) : 758 - 761
  • [27] PREVENTION OF VENOUS-BLOOD GAS EMBOLISM WITH BLOOD MICRO-FILTERS
    WATSON, BG
    PEARSON, DT
    WILLIAMS, W
    ANAESTHESIA, 1977, 32 (02) : 174 - 176
  • [28] PERCUTANEOUS SAMPLE FOR BLOOD-GAS ANALYSIS - ARTERIAL OR VENOUS-BLOOD
    SCAMMAN, FL
    ANESTHESIOLOGY, 1979, 51 (05) : 474 - 474
  • [29] ARTERIALIZATION OF VENOUS-BLOOD
    CAIOZZO, VJ
    WILLS, CA
    ELLIS, JF
    HAWKSWORTH, A
    DAVIS, JA
    PRIETTO, CA
    MCMASTER, WC
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 1982, 3 (01) : 63 - 63
  • [30] LONG-TERM SAMPLING OF CEREBRAL VENOUS-BLOOD IN CONSCIOUS RATS
    FRERICHS, KU
    LINDSBERG, PJ
    HALLENBECK, JM
    FEUERSTEIN, GZ
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 1989, 9 (06): : 902 - 905