PRELIMINARY EXPERIENCE WITH THE TORONTO SPV STENTLESS PORCINE BIOPROSTHESIS FOR AORTIC-VALVE REPLACEMENT

被引:8
|
作者
KONERTZ, W
HERRMANN, M
KNAUTH, M
STABENOW, I
DAVID, T
机构
[1] HUMBOLDT UNIV BERLIN,CHARITE,DEPT CARDIAC SURG,O-1086 BERLIN,GERMANY
[2] MARTIN LUTHER UNIV HALLE WITTENBERG,DEPT CARDIAC SURG,O-4010 HALLE,GERMANY
[3] MARTIN LUTHER UNIV HALLE WITTENBERG,DEPT CARDIOL,O-4010 HALLE,GERMANY
[4] TORONTO HOSP,DIV CARDIOVASC SURG,TORONTO,ON,CANADA
[5] UNIV TORONTO,TORONTO M5S 1A1,ONTARIO,CANADA
来源
THORACIC AND CARDIOVASCULAR SURGEON | 1994年 / 42卷 / 01期
关键词
STENTLESS AORTIC BIOPROSTHESIS; AORTIC VALVE REPLACEMENT;
D O I
10.1055/s-2007-1016452
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
From November 1992 to March 1993 fourteen patients received the Toronto SPV stentless porcine xenograft as aortic valve replacement. Median age was 56 years (range 32-70 years). 7 patients were male and 7 female. Implanted valve sizes ranged from 23 mm to 29 mm, the majority of patients received valves with 27 and 29 mm tissue diameter. A learning process was evident by aortic crossclamp time decreasing with experience. No valve-related mortality or morbidity occurred. Postoperatively echocardiography showed near normal valve performance in most patients. The longevity of the valve, however, still has to be established. Meanwhile we continue the implant of stentless bioprostheses as aortic valve substitutes in selected patients.
引用
收藏
页码:36 / 39
页数:4
相关论文
共 50 条
  • [41] Aortic valve replacement with stentless porcine aortic valves: A ten-year experience
    David, TE
    Feindel, CM
    Scully, HE
    Bos, J
    Rakowski, H
    JOURNAL OF HEART VALVE DISEASE, 1998, 7 (03): : 250 - 254
  • [42] ISOLATED REPLACEMENT OF A PROSTHESIS OR A BIOPROSTHESIS IN THE AORTIC-VALVE POSITION
    ANTUNES, MJ
    AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (04): : 350 - 352
  • [43] Stented within a stentless aortic valve. A simple surgical solution for the replacement of a stentless aortic bioprosthesis
    Panagiotou, Matthew
    Kogerakis, Nektarios
    Crockett, James R.
    Economidou, Stella
    INTERACTIVE CARDIOVASCULAR AND THORACIC SURGERY, 2010, 10 (01) : 7 - 8
  • [44] Long-term results of aortic valve replacement with the St. Jude Toronto stentless porcine valve
    Desai, ND
    Merin, O
    Cohen, GN
    Herman, J
    Mobilos, S
    Sever, JY
    Fremes, SE
    Goldman, BS
    Christakis, GT
    ANNALS OF THORACIC SURGERY, 2004, 78 (06): : 2076 - 2082
  • [45] STENTLESS PORCINE BIOPROSTHESES IN THE TREATMENT OF AORTIC-VALVE INFECTIVE ENDOCARDITIS
    SANTINI, F
    MUSAZZI, A
    BERTOLINI, P
    PUGLIESE, P
    FABBRI, A
    FAGGIAN, G
    PRIOLI, A
    MAZZUCCO, A
    JOURNAL OF CARDIAC SURGERY, 1995, 10 (03) : 205 - 209
  • [46] Aortic Valve Replacement With the Stentless Freedom SOLO Bioprosthesis: A Systematic Review
    Wollersheim, Laurens W.
    Li, Wilson W.
    Bouma, Berto J.
    Repossini, Alberto
    van der Meulen, Jan
    de Mol, Bas A.
    ANNALS OF THORACIC SURGERY, 2015, 100 (04): : 1496 - 1504
  • [47] Left ventricle remodeling after aortic valve replacement with a stentless bioprosthesis
    Valfrè, C
    Ius, P
    Zussa, C
    Rigo, F
    Bianchini, R
    Polesel, E
    Zennaro, RJ
    JOURNAL OF HEART VALVE DISEASE, 2004, 13 : S69 - S69
  • [48] Outcome of Aortic Valve and/or Root Replacement with Stentless Bioprosthesis in Guch Patients
    Michielon, G.
    Brancaccio, G.
    Carlo, D. D.
    Amodeo, A.
    Perri, G.
    Toscano, A.
    Carotti, A.
    Pongiglione, G.
    CARDIOLOGY, 2012, 121 (02) : 120 - 120
  • [49] Medtronic stentless Freestyle® porcine aortic valve replacement
    Ennker, J.
    Albert, A.
    Florath, I.
    AORTIC ROOT SURGERY: THE BIOLOGICAL SOLUTION, 2010, : 366 - +
  • [50] The upside-down stentless aortic bioprosthesis to tricuspid valve replacement
    Pisani, Paolo
    Bichi, Samuele
    Cricco, Antonio
    Pennetta, Antonio
    Esposito, Giampiero
    JOURNAL OF CARDIOVASCULAR MEDICINE, 2010, 11 (10) : 762 - 763