LONG-DURATION, LOW-FLOW SEVOFLURANE ANESTHESIA USING 2 CARBON-DIOXIDE ABSORBENTS - QUANTIFICATION OF DEGRADATION PRODUCTS IN THE CIRCUIT

被引:85
|
作者
BITO, H
IKEDA, K
机构
[1] Hamamatsu Univ. School of Medicine, Hamamatsu 431-31
关键词
ANESTHETIC SYSTEM; LOW-FLOW CIRCUIT; ANESTHETICS; VOLATILE; SEVOFLURANE; CARBON DIOXIDE; ABSORPTION; BARALYME SODA LIME;
D O I
10.1097/00000542-199408000-00011
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Sevoflurane reacts with soda lime, generating degradation products. The concentrations of sevoflurane degradation products in a low-flow circuit have been reported for anesthesia times of less than 5 h. In this study, sevoflurane degradation products generated during low-flow anesthesia exceeding 10 h were examined. Methods: Sixteen patients received sevoflurane anesthesia with a fresh gas flow rate of 1 l/min. In eight patients, soda lime was used as the CO2 absorbent; in the other eight patients, Baralyme was used. During anesthesia, the concentrations of degradation products in the circuit, the temperature of the CO2 absorbent, inspired and end-tidal sevoflurane concentrations, and the volume of CO2 eliminated by the patient were measured. Gas was sampled from the inspiratory limb of the circuit and analyzed by gas chromatography. Results: Two degradation products, CF2 = C(CF3) - O - CH2F (compound A) and CH3OCF2CH(CF3)OCH2F (compound B), were detected. In the soda lime group, the individual maximum concentration of compound A was 23.6 +/- 2.9 (12.0-37.4) ppm. In the Baralyme group, the concentration was 32.0 +/- 2.3 (23.5-41.3) ppm. The individual maximum concentration of compound A in the Baralyme group was significant higher than that in the soda lime group. Compound B was detected in two patients, reaching a maximum concentration of 0.2 ppm. The end-tidal sevoflurane concentration, temperature of the CO2 absorbent, and volume of CO2 eliminated by the patient were the same in both groups. Conclusions: The degradation products detected were at low concentrations in long-duration, low-flow anesthesia with sevoflurane. Baralyme produced higher concentrations of degradation products than soda lime.
引用
收藏
页码:340 / 345
页数:6
相关论文
共 14 条
  • [1] PLASMA INORGANIC FLUORIDE AND INTRACIRCUIT DEGRADATION PRODUCT CONCENTRATIONS IN LONG-DURATION, LOW-FLOW SEVOFLURANE ANESTHESIA
    BITO, H
    IKEDA, K
    ANESTHESIA AND ANALGESIA, 1994, 79 (05): : 946 - 951
  • [2] DEGRADATION PRODUCTS OF SEVOFLURANE DURING LOW-FLOW ANESTHESIA
    BITO, H
    IKEDA, K
    BRITISH JOURNAL OF ANAESTHESIA, 1995, 74 (01) : 56 - 59
  • [3] Novel radiator for carbon dioxide absorbents in low-flow anesthesia
    Hirabayashi, G
    Mitsui, T
    Kakinuma, T
    Ogihara, Y
    Matsumoto, S
    Isshiki, A
    Watanabe, Y
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2003, 33 (03): : 313 - 319
  • [4] QUANTIFICATION OF THE DEGRADATION PRODUCTS OF SEVOFLURANE IN 2 CO2 ABSORBANTS DURING LOW-FLOW ANESTHESIA IN SURGICAL PATIENTS
    FRINK, EJ
    MALAN, TP
    MORGAN, SE
    BROWN, EA
    MALCOMSON, M
    BROWN, BR
    ANESTHESIOLOGY, 1992, 77 (06) : 1064 - 1069
  • [5] Compound A concentrations during low-flow sevoflurane anesthesia correlate directly with the concentration of monovalent bases in carbon dioxide absorbents
    Higuchi, H
    Adachi, Y
    Arimura, S
    Kanno, M
    Satoh, T
    ANESTHESIA AND ANALGESIA, 2000, 91 (02): : 434 - 439
  • [6] Long-duration low-flow sevoflurane and lsoflurane effects on postoperative renal and hepatic function
    Kharasch, ED
    Frink, EJ
    Artru, A
    Michalowski, P
    Rooke, GA
    Nogami, W
    ANESTHESIA AND ANALGESIA, 2001, 93 (06): : 1511 - 1520
  • [7] MOLECULAR-SIEVES - AN ALTERNATIVE METHOD OF CARBON-DIOXIDE REMOVAL WHICH DOES NOT GENERATE COMPOUND-A DURING SIMULATED LOW-FLOW SEVOFLURANE ANESTHESIA
    FEE, JPH
    MURRAY, JM
    LUNEY, SR
    ANAESTHESIA, 1995, 50 (10) : 841 - 845
  • [8] Cardiorespiratory effects of low-flow and closed circuit inhalation anesthesia, using sevoflurane delivered with an in-circuit vaporizer and concentrations of compound A
    Muir, WW
    Gadawski, J
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 1998, 59 (05) : 603 - 608
  • [9] Long-Duration Carbon Dioxide Anesthesia of Fish Using Ultra Fine (Nano-Scale) Bubbles
    Kugino, Kenji
    Tamaru, Shizuka
    Hisatomi, Yuko
    Sakaguchi, Tadashi
    PLOS ONE, 2016, 11 (04):
  • [10] EVALUATION OF PROLONGED SEVOFLURANE ANESTHESIA WITH 2 CO2 ABSORBANTS USING LOW-FLOW TECHNIQUE
    BITO, H
    IKEDA, K
    ANESTHESIA AND ANALGESIA, 1994, 78 (02): : U34 - U34