Experiments of Micro Jet Injection for Bio-Medical Application

被引:1
|
作者
Ham, Young-Bog [1 ,2 ]
An, Byeung-Cheol [1 ]
Trimzi, Mojiz Abbas [1 ]
Kim, Jong-Dae [2 ]
Lee, Gi-Tae [2 ]
Park, Jung-Ho [1 ,2 ]
Yun, So-Nam [1 ,2 ]
机构
[1] Univ Sci & Technol, Plant Syst & Machinery, Daejeon, South Korea
[2] Korea Inst Machinery & Mat, Extreme Mech Engn Res Div, Taejon, South Korea
关键词
Water Hydraulic; Jet Injection; Piezoelectric Actuator;
D O I
10.3795/KSME-B.2016.40.10.681
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
It is essential for micro jet injectors in the biomedical sector to operate under high pressure. High pressure injection, however, is accompanied by high volumes. On/Off valves that can be operated at high speeds have been used to address this problem. In this research, piezoelectric actuators which have a response frequency of the order of hundreds of kilohertz were used as the On/Off valve and experiments were applied. Researchers developed a controller to precisely manipulate the piezoelectric valve with various waveforms. They also fabricated five types of nozzles to consider the effect of nozzle type on injection. This allowed researchers to manipulate and confirm factors that can affect the injection volume and force. Results of this experiment have shown how to decrease the injection volume and increase the injection force. and it is predicted that the optimized injection volume and force value can be determined depending on the skin type.
引用
收藏
页码:681 / 687
页数:7
相关论文
共 50 条
  • [31] THE FUTURE OF BIO-MEDICAL ENGINEERING
    BAKER, RJ
    COLVIN, JB
    JOURNAL OF BIOMEDICAL ENGINEERING, 1991, 13 (03): : 267 - 268
  • [32] Calixarenes in Bio-Medical Researches
    Rodik, Roman V.
    Boyko, Vyacheslav I.
    Kalchenko, Vitaly I.
    CURRENT MEDICINAL CHEMISTRY, 2009, 16 (13) : 1630 - 1655
  • [33] Application of Table based Similarity to Classification of Bio-Medical Documents
    Jo, Taeho
    2013 IEEE INTERNATIONAL CONFERENCE ON GRANULAR COMPUTING (GRC), 2013, : 162 - 166
  • [34] MICROPROCESSOR BASED WAVEFORM GENERATOR FOR BIO-MEDICAL APPLICATION.
    Verma, H.K.
    Ghai, A.K.
    Journal of the Institution of Engineers (India), Part ET: Electronics & Telecommunication Engineering Division, 1980, 60 (pt ET 3): : 96 - 98
  • [35] Bio-medical analysis framework
    Mohorcic, Miha
    Depolli, Matjaz
    2017 40TH INTERNATIONAL CONVENTION ON INFORMATION AND COMMUNICATION TECHNOLOGY, ELECTRONICS AND MICROELECTRONICS (MIPRO), 2017, : 270 - 275
  • [36] Bio-medical physics for nurses
    Kurup, P. G. G.
    JOURNAL OF MEDICAL PHYSICS, 2007, 32 (02) : 78 - +
  • [37] LIMITS OF BIO-MEDICAL EXPLANATION
    HELMAN, CG
    LANCET, 1991, 337 (8749): : 1080 - 1083
  • [38] Bio-medical electronics - Update
    Lindberg, DAB
    PROCEEDINGS OF THE IEEE, 2000, 88 (04) : 590 - 592
  • [39] How the Formal Description of the Transmembrane Proteins can Reduce the Bio-Medical Experiments
    Aman, Bogdan
    Ciobanu, Gabriel
    2019 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2019,
  • [40] Micro- and nano-systems for chemical/bio-medical analysis and diagnostics
    Grabiec, Piotr
    26TH EUROPEAN CONFERENCE ON SOLID-STATE TRANSDUCERS, EUROSENSOR 2012, 2012, 47 : 1502 - 1505