ELECTRONIC LIFETIME MEASUREMENTS WITH A GE(LI) DETECTOR USING CENTROID-SHIFT METHOD

被引:2
|
作者
DUMARCHIEVANVOORTHUYSEN, EH
机构
来源
NUCLEAR INSTRUMENTS & METHODS | 1978年 / 156卷 / 03期
关键词
D O I
10.1016/0029-554X(78)90755-3
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
引用
收藏
页码:547 / 551
页数:5
相关论文
共 50 条
  • [21] DELAYED COINCIDENCE EXPERIMENT USING A GE(LI) DETECTOR TO ESTIMATE LIFETIME OF 404.8 KEV STATE IN XE-131
    GERST, E
    ENGEL, H
    SCHNEIDER, H
    NUCLEAR INSTRUMENTS & METHODS, 1975, 128 (01): : 189 - 190
  • [22] LIFETIME MEASUREMENTS WITH THE DOPPLER SHIFT ATTENUATION METHOD USING A THICK HOMOGENEOUS PRODUCTION TARGET - VERIFICATION OF THE METHOD
    Ertoprak, A.
    Cederwall, B.
    Jakobsson, U.
    Nyako, B. M.
    Nyberg, J.
    Davies, P.
    Doncel, M.
    De France, G.
    Kuti, I.
    Napoli, D. R.
    Wadsworth, R.
    Ghugre, S. S.
    Raut, R.
    Akkus, B.
    Al-Azri, H.
    Algora, A.
    de Angelis, G.
    Atac, A.
    Back, T.
    Boso, A.
    Clement, E.
    Debenham, D. M.
    Dombradi, Zs.
    Erturk, S.
    Gadea, A.
    Moradi, F. Ghazi
    Gottardo, A.
    Huyuk, T.
    Ideguchi, E.
    Jaworski, G.
    Li, H.
    Michelagnoli, C.
    Modamio, V.
    Palacz, M.
    Petrache, C. M.
    Recchia, F.
    Sandzelius, M.
    Siciliano, M.
    Timar, J.
    Valiente-Dobon, J. J.
    Xiao, Z. G.
    ACTA PHYSICA POLONICA B, 2017, 48 (03): : 325 - 329
  • [23] COMPARISON OF A GE(LI) DETECTOR WITH A GE(LI) - NAL(TL) COMPTON SUPPRESSION SPECTROMETER FOR LOW-LEVEL ACTIVITY MEASUREMENTS
    SITAR, B
    JADERNA ENERGIE, 1977, 23 (09): : 342 - 344
  • [24] METHOD FOR DETERMINATION OF GE(LI) DETECTOR EFFICIENCIES FOR GAMMA-RAYS
    ALIAN, A
    SANAD, W
    HASSAN, AM
    RADIOCHEMICAL AND RADIOANALYTICAL LETTERS, 1975, 22 (06): : 371 - 378
  • [25] PRECISION MEASUREMENTS OF SOME GAMMA-TRANSITION ENERGIES IN 800 KEV REGION USING A GE(LI) DETECTOR
    PARSIGNA.D
    PHYSICS LETTERS, 1965, 18 (01): : 36 - &
  • [26] APPLICATION OF A PULSE SHAPE SELECTION METHOD TO A TRUE COAXIAL GE(LI) DETECTOR FOR MEASUREMENTS OF NANOSECONDS HALF-LIVES
    MOSZYNSKI, M
    BENGTSON, B
    NUCLEAR INSTRUMENTS & METHODS, 1970, 80 (02): : 233 - +
  • [27] PROBING CONFIGURATION INTERACTION USING STARK SHIFT AND LIFETIME MEASUREMENTS
    GALLAGHER, TF
    SANDNER, W
    SAFINYA, KA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1980, 25 (09): : 1145 - 1146
  • [28] LIFETIME OF THE O-2+ STATE OF GE-72 DETERMINED BY DELAYED AUTO-COINCIDENCE OF A GE(LI) DETECTOR
    BRAUN, G
    BOCKISCH, A
    NEUWIRTH, W
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 224 (1-2): : 112 - 116
  • [29] (N,N' GAMMA) REACTION STUDY USING A GE(LI)-DETECTOR
    KLOTZ, G
    WALTER, G
    REVUE DE PHYSIQUE APPLIQUEE, 1969, 4 (02): : 271 - &
  • [30] LIFETIMES OF EXCITED STATES IN IN-115 USING A GE(LI) DETECTOR
    SVENSSON, LG
    NAINAN, TD
    HEGE, EK
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A, 1971, A 3 (04): : 680 - &