AN ALGORITHM FOR THE REDUCTION OF METAL CLIP ARTIFACTS IN CT RECONSTRUCTIONS

被引:205
|
作者
GLOVER, GH
PELC, NJ
机构
关键词
D O I
10.1118/1.595032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:799 / 807
页数:9
相关论文
共 50 条
  • [21] Reduction of metal artifacts using subtracted CT projection data
    Tolakanahalli, R
    Medow, JE
    Hsieh, J
    Chen, GH
    Mistretta, CA
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 636 - 643
  • [22] CT of metal implants: Reduction of artifacts using an extended CT scale technique
    Link, TM
    Berning, W
    Scherf, S
    Joosten, U
    Joist, A
    Engelke, K
    Daldrup-Link, HE
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2000, 24 (01) : 165 - 172
  • [23] Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms
    Nils Große Hokamp
    V. Neuhaus
    N. Abdullayev
    K. Laukamp
    S. Lennartz
    A. Mpotsaris
    J. Borggrefe
    Skeletal Radiology, 2018, 47 : 195 - 201
  • [24] Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms
    Hokamp, Nils Grosse
    Neuhaus, V.
    Abdullayev, N.
    Laukamp, K.
    Lennartz, S.
    Mpotsaris, A.
    Borggrefe, J.
    SKELETAL RADIOLOGY, 2018, 47 (02) : 195 - 201
  • [25] Metal artifact reduction by virtual monoenergetic reconstructions from brain CT
    Mellander, Helena
    Fransson, Veronica
    Ydstrom, Kristina
    Latt, Jimmy
    Ullberg, Teresa
    Wasselius, Johan
    Ramgren, Birgitta
    EUROPEAN JOURNAL OF RADIOLOGY OPEN, 2023, 10
  • [26] CT of metal implants: Reduction of artifacts using an implemented extended CT scale technique
    Link, TM
    Berning, W
    Scherf, S
    Joosten, U
    Engelke, K
    Woertler, K
    RADIOLOGY, 1998, 209P : 465 - 465
  • [27] Prostate Postimplant CT With Metal Artifacts Reduction for Improvement of Seed Localization
    Shiraishi, Y.
    Yamada, Y.
    Ohashi, T.
    Hanada, T.
    Jinzaki, M.
    Kuribayashi, S.
    Shigematsu, N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S417 - S417
  • [28] Assessing the Severity of Metal Artifacts and Detectability of Lesions in CT Metal Artifact Reduction Images
    Topbas, C.
    Dong, F.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [29] CT metal artifacts in patients with total hip replacements: for artifact reduction monoenergetic reconstructions and post-processing algorithms are both efficient but not similar
    Kai Roman Laukamp
    Simon Lennartz
    Victor-Frederic Neuhaus
    Nils Große Hokamp
    Robert Rau
    Markus Le Blanc
    Nuran Abdullayev
    Anastasios Mpotsaris
    David Maintz
    Jan Borggrefe
    European Radiology, 2018, 28 : 4524 - 4533
  • [30] CT metal artifacts in patients with total hip replacements: for artifact reduction monoenergetic reconstructions and post-processing algorithms are both efficient but not similar
    Laukamp, Kai Roman
    Lennartz, Simon
    Neuhaus, Victor-Frederic
    Hokamp, Nils Grosse
    Rau, Robert
    Le Blanc, Markus
    Abdullayev, Nuran
    Mpotsaris, Anastasios
    Maintz, David
    Borggrefe, Jan
    EUROPEAN RADIOLOGY, 2018, 28 (11) : 4524 - 4533