摘要
Three-dimensional (3D) image rendering was performed in 14 patients who had undergone magnetic resonance (MR) imaging for focal brain lesions. The MR study included the magnetization-prepared rapid gradient-echo (MP-RAGE) sequence with 64 or 128 partitions. Resultant contiguous sections 2.5 or 1.25 mm thick, respectively, were obtained. Images were acquired before and after administration of gadopentetate dimeglumine. Resultant 3D data sets were processed on a commercially available workstation. Correlative surgical observation was performed in four cases. All data sets were successfully processed into 3D images. The precontrast images proved superior to gadolinium-enhanced images for brain surface rendering. Postcontrast images proved superior for reconstruction of tumors and vascular structures. The 64-partition data set proved sufficient for all postprocessing. Coronal orientation was preferred to sagittal orientation for surface rendering because it provided optimal orthogonal orientation of sulcal and gyral brain surface features. Three-dimensional rendition allowed easy superposition of lesion, brain, vessels, and scalp features-all useful for surgical planning. The central sulcus was easily recognized in the midline partitions and traced mediolaterally for projection on the cortical surface. MP-RAGE provides a 3D data set that can be obtained in just over 3 minutes, from which clinically useful 3D renderings are possible. The rapidity of acquisition and capability for 3D rendering provides additional clinical utility.
引用
收藏
页码:656 / 662
页数:7
相关论文
共 50 条
  • [31] MP RAGE - A 3-DIMENSIONAL, T1-WEIGHTED, GRADIENT-ECHO SEQUENCE - INITIAL EXPERIENCE IN THE BRAIN
    BRANTZAWADZKI, M
    GILLAN, GD
    NITZ, WR
    RADIOLOGY, 1992, 182 (03) : 769 - 775
  • [32] 3-DIMENSIONAL DOSE MAPPING FROM GAMMA KNIFE TREATMENT USING A DOSIMETER GEL AND MR-IMAGING
    OLSSON, LE
    ARNDT, J
    FRANSSON, A
    NORDELL, B
    RADIOTHERAPY AND ONCOLOGY, 1992, 24 (02) : 82 - 86
  • [33] DIAGNOSTIC ADVANTAGES OF 3-DIMENSIONAL (FOURIER-TRANSFORM) MR-IMAGING IN SPINAL-CORD LESIONS
    VOIGT, K
    THRON, A
    SCHROTH, G
    NEURORADIOLOGY, 1985, 27 (04) : 366 - 366
  • [34] VARIATIONS IN VENOUS AND SEGMENTAL ANATOMY OF THE LIVER - 2-DIMENSIONAL AND 3-DIMENSIONAL MR-IMAGING IN HEALTHY-VOLUNTEERS
    VANLEEUWEN, MS
    FERNANDEZ, MA
    VANES, HW
    STOKKING, R
    DILLON, EV
    FELDBERG, MAM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (06) : 1337 - 1345
  • [35] 3-DIMENSIONAL MR-IMAGING OF BRAIN SURFACE ANOMALIES IN FUKUYAMA-TYPE CONGENITAL MUSCULAR-DYSTROPHY
    TODA, T
    WATANABE, T
    MATSUMURA, K
    SUNADA, Y
    YAMADA, H
    NAKANO, I
    MANNEN, T
    KANAZAWA, I
    SHIMIZU, T
    MUSCLE & NERVE, 1995, 18 (05) : 508 - 517
  • [36] DETECTION OF KNEE HYALINE CARTILAGE DEFECTS USING FAT-SUPPRESSED 3-DIMENSIONAL SPOILED GRADIENT-ECHO MR-IMAGING - COMPARISON WITH STANDARD MR-IMAGING AND CORRELATION WITH ARTHROSCOPY
    DISLER, DG
    MCCAULEY, TR
    WIRTH, CR
    FUCHS, MD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 377 - 382
  • [37] QUANTIFICATION OF THE VOLUME OF ARTICULAR-CARTILAGE IN THE METACARPOPHALANGEAL JOINTS OF THE HAND - ACCURACY AND PRECISION OF 3-DIMENSIONAL MR-IMAGING
    PETERFY, CG
    VANDIJKE, CF
    LU, Y
    NGUYEN, A
    CONNICK, TJ
    KNEELAND, JB
    TIRMAN, PFJ
    LANG, P
    DENT, S
    GENANT, HK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1995, 165 (02) : 371 - 375
  • [38] CAROTID AND VERTEBRAL ARTERY DISSECTIONS - 3-DIMENSIONAL TIME-OF-FLIGHT MR-ANGIOGRAPHY AND MR-IMAGING VERSUS CONVENTIONAL ANGIOGRAPHY
    LEVY, C
    LAISSY, JP
    RAVEAU, V
    AMARENCO, P
    SERVOIS, V
    BOUSSER, MG
    TUBIANA, JM
    RADIOLOGY, 1994, 190 (01) : 97 - 103
  • [39] Small isotropic 3D diffusion tensor mapping of the rat brain using water-excitation diffusion-weighted 3D MP-RAGE MR sequence
    Numano, T.
    Homma, K.
    Iwasaki, N.
    Hyodo, K.
    Nitta, N.
    Hirose, T.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 1447 - +
  • [40] PITUITARY MICROADENOMAS - DIAGNOSIS WITH 2-DIMENSIONAL AND 3-DIMENSIONAL MR IMAGING AT 1.5 T BEFORE AND AFTER INJECTION OF GADOLINIUM
    STADNIK, T
    STEVENAERT, A
    BECKERS, A
    LUYPAERT, R
    BUISSERET, T
    OSTEAUX, M
    RADIOLOGY, 1990, 176 (02) : 419 - 428