ECG SIGNALS NOISE REMOVAL: SELECTION AND OPTIMIZATION OF THE BEST ADAPTIVE FILTERING ALGORITHM BASED ON VARIOUS ALGORITHMS COMPARISON

被引:27
|
作者
Ebrahimzadeh, Elias [1 ]
Pooyan, Mohammad [2 ]
Jahani, Sahar [1 ]
Bijar, Ahmad [3 ]
Setaredan, Seyed Kamal [4 ]
机构
[1] Univ Tehran, Coll Engn, Sch Elect & Comp Engn, Tehran, Iran
[2] Shahed Univ, Dept Biomed Engn, Fac Engn, Tehran, Iran
[3] Univ Grenoble, TIMC IMAG Lab, UMR CNRS 5525, Grenoble, France
[4] Univ Tehran, Control & Intelligent Proc Ctr Excellence, Sch Elect & Comp Engn, Coll Engn, Tehran, Iran
来源
BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS | 2015年 / 27卷 / 04期
关键词
Adaptive filter; noise reduction; UNANR algorithm; LMS algorithm; optimal RLS filter; ECG signal;
D O I
10.4015/S1016237215500386
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The electrocardiogram (ECG) is generally used for the diagnosis of cardiovascular diseases. In many of the biomedical applications, it is necessary to remove the noise from ECG recordings. Several adaptive filter structures have been proposed for noise cancellation. Compared to the least mean square (LMS) method, the unbiased and normalized adaptive noise reduction (UNANR) algorithm has better performance, as mentioned in previous investigations. In this paper, we review various kinds of ECG noise reduction algorithms. To provide a detailed and fair comparison, all normalized LMS (NLMS), Block LMS (BLMS), recursive least squares (RLS) and UNANR algorithms are implemented and their performance have been assessed using the same dataset and compared to different state-of-the-art approaches. Then, the performance analysis of all five algorithms is presented and compared in term of mean squared error (MSE), computational complexity and stability. The obtained results revealed that RLS method is much more effective and powerful than other methods in ECG noise cancellation, and even better than UNANR. Then, in order to reach the best performance of the mentioned filter and also, to minimize the output signal error, the optimized parameters of the algorithm were defined and results were investigated. The obtained outcomes show that the best Lambda (lambda) occurs between 0.05 and 0.9, so that the convergence rate of the optimized RLS filter is faster than others. It not only decreases the noise, but also the ECG waveform is better conserved. Furthermore, the introduced optimized method with adaptive threshold value would have great potential in biomedical application of signal processing and other fields.
引用
收藏
页数:13
相关论文
共 50 条
  • [21] Real Time EMG Noise Cancellation from ECG Signals using Adaptive Filtering
    El Hanine, M.
    Abdelmounim, E.
    Haddadi, R.
    Belaguid, A.
    ICCWCS'17: PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON COMPUTING AND WIRELESS COMMUNICATION SYSTEMS, 2017,
  • [22] Comparative research of various adaptive algorithms for noise cancellation in speech signals
    Kumar, Aniket
    Goel, Pankaj
    Gupta, V. K.
    Chandra, Mahesh
    2016 2ND IEEE INTERNATIONAL CONFERENCE ON CONTROL, COMPUTING, COMMUNICATION AND MATERIALS (ICCCCM), 2016,
  • [23] Artefacts removal from ecg signal: Dragonfly optimization-based learning algorithm for neural network-enhanced adaptive filtering
    Viswanadham T.
    Kumar P.R.
    Scalable Computing, 2020, 21 (02): : 247 - 263
  • [24] ARTEFACTS REMOVAL FROM ECG SIGNAL: DRAGONFLY OPTIMIZATION-BASED LEARNING ALGORITHM FOR NEURAL NETWORK-ENHANCED ADAPTIVE FILTERING
    Viswanadham, Talabattula
    Kumar, P. Rajesh
    SCALABLE COMPUTING-PRACTICE AND EXPERIENCE, 2020, 21 (02): : 247 - 263
  • [25] Noise Filtering for MoireFringe Signals Based on Variable Step Size Adaptive Neural Network Algorithm
    Lv Meng-jun
    Guo Qi
    Zhang Chun-liang
    Meng Yang
    5TH INTERNATIONAL SYMPOSIUM ON ADVANCED OPTICAL MANUFACTURING AND TESTING TECHNOLOGIES: OPTICAL TEST AND MEASUREMENT TECHNOLOGY AND EQUIPMENT, 2010, 7656
  • [26] Improved range selection method for evolutionary algorithm based adaptive filtering of EEG/ERP signals
    Ahirwal, M. K.
    Kumar, A.
    Singh, G. K.
    NEUROCOMPUTING, 2014, 144 : 282 - 294
  • [27] A new algorithm for the compression of ECG signals based on mother wavelet parameterization and best-threshold levels selection
    Abo-Zahhad, Mohammed
    Al-Ajlouni, Ahmad F.
    Ahmed, Sabah M.
    Schilling, R. J.
    DIGITAL SIGNAL PROCESSING, 2013, 23 (03) : 1002 - 1011
  • [28] A real-time adaptive filtering approach to motion artefacts removal from ECG signals
    Martini, Nicola
    Milanesi, Matteo
    Vanello, Nicola
    Positano, Vincenzo
    Santarelli, Maria Filomena
    Landini, Luigi
    INTERNATIONAL JOURNAL OF BIOMEDICAL ENGINEERING AND TECHNOLOGY, 2010, 3 (3-4) : 233 - 245
  • [29] Performance Analysis of Adaptive Algorithms for removal of Low Frequency Noise from ECG Signal
    Qureshi, Rizwan
    Rizvi, Syed Ali Raza
    Musavi, Sayed Haider Abbas
    Khan, Sadaf
    Khurshid, Khurram
    2017 INTERNATIONAL CONFERENCE ON INNOVATIONS IN ELECTRICAL ENGINEERING AND COMPUTATIONAL TECHNOLOGIES (ICIEECT), 2017,
  • [30] A new robust adaptive algorithm based adaptive filtering for noise cancellation
    Awwab Qasim Jumaah Althahab
    Analog Integrated Circuits and Signal Processing, 2018, 94 : 217 - 231