THE THERMO-LUMINESCENCE (TL) CHARACTERISTICS OF LIF (MG,CU,P) PHOSPHOR AND ITS APPLICATION IN RADIATION-DOSIMETRY

被引:2
|
作者
SUN, FY
DAI, GF
YUAN, SL
SONG, SJ
机构
[1] Chinese Acad of Medical Sciences, Tianjin, China, Chinese Acad of Medical Sciences, Tianjin, China
关键词
LITHIUM FLUORIDE;
D O I
10.1016/0022-2313(88)90480-2
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
引用
收藏
页码:881 / 882
页数:2
相关论文
共 50 条
  • [31] Thermally and optically stimulated luminescence in LiF:Mg,Ti: Application to mixed high/low ionization density radiation dosimetry
    Oster L.
    Horowitz Y.S.
    Druzhyna S.
    Bulletin of the Russian Academy of Sciences: Physics, 2016, 80 (1) : 9 - 13
  • [32] Determination of LiF:Mg,Ti and LiF:Mg,Cu,P TL efficiency for X-rays and their application to Monte Carlo simulations of dosemeter response
    Hranitzky, C.
    Stadtmann, H.
    Olko, P.
    RADIATION PROTECTION DOSIMETRY, 2006, 119 (1-4) : 483 - 486
  • [33] THERMO-LUMINESCENCE OF GAMMA-IRRADIATED MAKROFOL-E POLYCARBONATE ABOVE ROOM-TEMPERATURE AND ITS APPLICATION IN DOSIMETRY
    KHAZAL, KAR
    PIESCH, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 234 (02): : 367 - 372
  • [34] RSC: Optically stimulated emission of LiF:Mg,Cu,P - towards 3D optically stimulated luminescence dosimetry
    Nyemann, Jacob S.
    Jensen, Mads L.
    Nielsen, Camilla L.
    Bondgard, Karl-Emil T.
    Turtos, Rosana M.
    Julsgaard, Brian
    Petersen, Jorgen B. B.
    Muren, Ludvig P.
    Balling, Peter
    11TH INTERNATIONAL CONFERENCE ON 3D RADIATION DOSIMETRY, IC3DDOSE, 2022, 2167
  • [35] Photostimulated luminescence in CaxSr1-x:Eu,Sm phosphor ceramics and its application to radiation dosimetry
    Nanto, H
    Komori, H
    Araki, T
    Douguchi, Y
    Kusano, E
    Nasu, S
    Kinbara, A
    RARE-EARTH-DOPED MATERIALS AND DEVICES V, 2001, 4282 : 248 - 257
  • [36] THERMOLUMINESCENT RESPONSE OF (LIF)-LI-6 (MG,CU,P) AND (LIF)-LI-7 (MG,CU,P) TL CHIPS IN NEUTRON AND GAMMA-RAY MIXED RADIATION-FIELDS
    WANG, SS
    CAI, GG
    ZHOU, KQ
    ZHOU, RX
    RADIATION PROTECTION DOSIMETRY, 1990, 33 (1-4) : 247 - 250
  • [37] Influence of background exposure on detection and determination limits for a tl dosimetry system based on LiF:Mg,Cu,P(GR-200A)
    Tang, KY
    Liu, BX
    Zhu, HY
    Wang, YC
    Shen, WX
    SOLID STATE DOSIMETRY, PTS 1 AND 2, PROCEEDINGS, 2002, : A187 - A190
  • [38] 2-D dosimetry of a proton radiotherapy beam using large-area LiF: Mg,Cu,P TL detectors
    Czopyk, L.
    Cirrone, G. A. P.
    Cuttone, G.
    Klosowski, M.
    Olko, P.
    Sroka, U.
    Waligorski, M. P. R.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 977 - 980
  • [39] Influence of background exposure on detection and determination limits for a TL dosimetry system based on LiF:Mg,Cu,P(GR-200A)
    Tang, KY
    Liu, BX
    Zhu, HY
    Wang, YC
    Shen, WX
    RADIATION PROTECTION DOSIMETRY, 2002, 101 (1-4) : 187 - 190
  • [40] OSL and TL in LiF:Mg,Ti following alpha particle and beta ray irradiation:: Application to mixed-field radiation dosimetry
    Oster, L.
    Horowitz, Y. S.
    Podpalov, L.
    RADIATION PROTECTION DOSIMETRY, 2008, 128 (03) : 261 - 265