摘要
This study evaluated (1) the effect of known reductions in the output of curing lights on the depth of cure of various resins as determined by hardness measurements, and (2) the ability of the clinician to detect reduced light output by use of an explorer to compare the hardness of the top and bottom surfaces of resin specimens. Curing light output was reduced stepwise from 10 to 70% with neutral density filters. Hardness values indicated polymerization of the top surface to be generally unaffected by light blockage. Bottom surfaces were greatly affected: more with a 30-second than a 60-second cure time. Three clinicians utilized an explorer to compare the tops and bottoms of specimens of known hardness. Evaluators were unable to routinely detect differences of less than 20 to 30 Barcol numbers. The data indicate that a light meter is a more efficacious means of monitoring curing light performance than is a tactile test of resin surface hardness.
引用
收藏
页码:47 / 52
页数:6
相关论文
共 50 条
  • [31] Curing depth of composite resin light cured by LED and halogen light-curing units
    Calixto, L. R.
    Lima, D. M.
    Queiroz, R. S.
    Rastelli, A. N. S.
    Bagnato, V. S.
    Andrade, M. F.
    LASER PHYSICS, 2008, 18 (11) : 1365 - 1369
  • [32] Curing of pit & fissure sealants using Light Emitting Diode curing units
    Platt, JA
    Clark, H
    Moore, BK
    OPERATIVE DENTISTRY, 2005, 30 (06) : 764 - 771
  • [33] Wear of resin composites polymerized by conventional halogen light curing and light emitting diodes curing units
    Kim, H
    Park, SH
    Jung, IY
    Jeon, SB
    Lee, KY
    ASBM6: ADVANCED BIOMATERIALS VI, 2005, 288-289 : 645 - 648
  • [34] EVALUATION OF LIGHT-INTENSITY EMITTED BY CURING UNITS
    SOBRINHO, LC
    DEGOES, MF
    CONSANI, S
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (03) : 805 - 805
  • [35] BLUE-LIGHT CURING UNITS - A DERMATOLOGICAL HAZARD
    BURKE, FJT
    WILSON, NHF
    BRITISH DENTAL JOURNAL, 1994, 176 (06) : 206 - 206
  • [36] Thermal emission by different light-curing units
    Yap, AUJ
    Soh, MS
    OPERATIVE DENTISTRY, 2003, 28 (03) : 260 - 266
  • [37] OPTICAL HAZARDS OF BLUE-LIGHT CURING UNITS
    HANCOCK, IR
    BRITISH DENTAL JOURNAL, 1985, 159 (12) : 390 - 391
  • [38] BLUE-LIGHT CURING UNITS - A DERMATOLOGICAL HAZARD
    CHADWICK, RG
    TRAYNOR, N
    MOSELEY, H
    GIBBS, N
    BRITISH DENTAL JOURNAL, 1994, 176 (01) : 17 - 21
  • [39] Characterization of heat emission of light-curing units
    Wahbi, Mohammed A.
    Aalam, F. A.
    Fatiny, F. I.
    Radwan, S. A.
    Eshan, I. Y.
    Al-Samadani, K. H.
    SAUDI DENTAL JOURNAL, 2012, 24 (02) : 91 - 98
  • [40] Shedding light on a potential hazard Dental light-curing units
    Fluent, Marie T.
    Ferracane, Jack L.
    Mace, James G.
    Shah, Anjali R.
    Price, Richard B.
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2019, 150 (12): : 1051 - 1058