EARLY AND LATE-PHASE EVENTS AFTER VALVE-REPLACEMENT WITH THE ST-JUDE MEDICAL PROSTHESIS IN 1200 PATIENTS

被引:102
|
作者
FERNANDEZ, J
LAUB, GW
ADKINS, MS
ANDERSON, WA
CHEN, C
BAILEY, BM
NEALON, LM
MCGRATH, LB
机构
[1] Deborah Heart and Lung Center, Department of Thoracic and Cardiovascular Surgery, Browns Mills, New Jersey
来源
关键词
D O I
10.1016/S0022-5223(94)70084-2
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
From May 1982 to August 1991, 1200 patients underwent valve replacement with the St. Jude Medical (St. Jude Medical, Inc., St. Paul, Mnn.) valve: 615 men (51%) and 585 women, mean age 58 years. Preoperatively, 830 patients (69%) were in functional class III or IV. A total of 611 patients (51%) had the aortic valve replaced, 490 (41%) the mitral valve, 2 (0.2%) the tricuspid valve, and 97 (8%) multiple valves. There were 81 hospital deaths (6.8%). Risk factors included older age (p = 0.0001), female gender (p = 0.02), higher preoperative left ventricular end-diastolic pressure (p = 0.05), previous cardiac operation (p = 0.003), longer aortic crossclamp time (p = 0.0001), and longer cardiopulmonary bypass time (p = 0.0001). Follow-up was 98% complete (3153 patient-years). There were 152 late deaths; 32 (21%) were considered valve-related: six thromboembolism, four valve thrombosis, five anticoagulant-related hemorrhage, eight prosthetic valve endocarditis, one paravalvular leak, and seven sudden death. The 5-year actuarial survival was 75%. Risk factors for late death included older age (p = 0.03), lower preoperative ejection fraction (p = 0.005), longer aortic crossclamp time (p = 0.0001), longer cardiopulmonary bypass time (p = 0.0001), previous cardiac operation (p = 0.02), and higher preoperative functional class (p = 0.0001). Actuarial freedom at 5 years from major thromboembolic events and anticoagulant-related hemorrhage was 97% and 95%, respectively. This value for valve thrombosis was 99%, for reoperation 96%, for prosthetic valve endocarditis 98%, and for paravalvular leak 96%. Actuarial freedom from all valve-related events and valve-related death at 5 years was 74% and 94%, respectively. We conclude that the low incidence of valve-related events and low mortality supports the continued use of the St. Jude Medical valve.
引用
收藏
页码:394 / 407
页数:14
相关论文
共 50 条
  • [21] THROMBOEMBOLIC RISK AND LATE SURVIVAL AFTER MITRAL-VALVE REPLACEMENT WITH THE ST-JUDE MEDICAL VALVE - COMMENTARY
    AROM, KV
    ANNALS OF THORACIC SURGERY, 1994, 58 (06): : 1727 - 1728
  • [22] HEMODYNAMIC-STUDIES AFTER IMPLANTATION OF ST-JUDE MEDICAL VALVE PROSTHESIS
    NIEHUES, B
    LUBBING, H
    BRAUN, V
    TAUCHERT, M
    DALICHAU, H
    ZEITSCHRIFT FUR KARDIOLOGIE, 1979, 68 (09): : 624 - 624
  • [23] 12 YEARS EXPERIENCE WITH THE ST-JUDE MEDICAL VALVE PROSTHESIS
    NAKANO, K
    KOYANAGI, H
    HASHIMOTO, A
    KITAMURA, M
    ENDO, M
    NAGASHIMA, M
    TOKUNAGA, H
    ANNALS OF THORACIC SURGERY, 1994, 57 (03): : 697 - 702
  • [24] JUDE,ST MEDICAL VALVE-REPLACEMENT - AN EVALUATION OF VALVE PERFORMANCE
    KINSLEY, RH
    ANTUNES, MJ
    COLSEN, PR
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1986, 92 (03): : 349 - 360
  • [25] HEART-VALVE REPLACEMENT WITH THE ST-JUDE MEDICAL PROSTHESIS - 1ST CLINICAL RESULTS
    HEHRLEIN, FW
    GOTTWIK, MG
    SCHLEPPER, M
    FRAEDRICH, G
    THORACIC AND CARDIOVASCULAR SURGEON, 1979, 27 (03): : 187 - 189
  • [26] 5-YEARS ACTUARIAL ANALYSIS AFTER HEART-VALVE REPLACEMENT WITH THE ST-JUDE MEDICAL PROSTHESIS
    FRAEDRICH, G
    HOGE, R
    FIEDLER, R
    HEHRLEIN, FW
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 282 - 285
  • [27] LATE COMPLICATIONS IN PATIENTS WITH BJORK-SHILEY AND ST-JUDE MEDICAL HEART-VALVE REPLACEMENT
    HORSTKOTTE, D
    KORFER, R
    SEIPEL, L
    BIRCKS, W
    LOOGEN, F
    CIRCULATION, 1983, 68 (03) : 175 - 184
  • [28] COMPARATIVE CLINICAL-EXPERIENCE WITH PORCINE BIOPROSTHETIC AND ST-JUDE VALVE-REPLACEMENT
    CZER, LSC
    MATLOFF, JM
    CHAUX, A
    DEROBERTIS, MA
    GRAY, RJ
    CHEST, 1987, 91 (04) : 503 - 514
  • [29] ECHOCARDIOGRAPHIC FEATURES OF THE CORRECTLY FUNCTIONING ST-JUDE MEDICAL VALVE PROSTHESIS
    AMANN, FW
    BURCKHARDT, D
    HASSE, J
    GRADEL, E
    AMERICAN HEART JOURNAL, 1981, 101 (01) : 45 - 51
  • [30] THE ST-JUDE MEDICAL BILEAFLET VALVE PROSTHESIS - A 5 YEAR EXPERIENCE
    CHAUX, A
    CZER, LSC
    MATLOFF, JM
    DEROBERTIS, MA
    STEWART, ME
    BATEMAN, TM
    KASS, RM
    LEE, ME
    GRAY, RJ
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1984, 88 (05): : 706 - 717