POLYETHYLENE WEAR IN TOTAL HIP-ARTHROPLASTY

被引:0
|
作者
BANKSTON, AB
CATES, H
RITTER, MA
KEATING, EM
FARIS, PM
机构
[1] CTR HIP & KNEE SURG, MOORESVILLE, IN 46158 USA
[2] ORTHOPED CLIN INC, BATON ROUGE, LA USA
关键词
D O I
暂无
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Polyethylene wear increasingly has been blamed for osteolysis and granuloma formation after total joint arthroplasty. The authors evaluated the wear difference between bearing surfaces of stainless steel, cobalt chrome, and titanium alloy. They also compared cemented all-polyethylene molded cups with cemented metal-backed molded acetabular cups. These were compared with molded and machined polyethylene cups. Two patient groups mere matched individually for gender, age, weight, and length of followup. Analyses were done using the technique of Livermore et al. The bearing surface evaluation consisted of 3 groups after matching, leaving 77 patients per group. Results showed linear wear rates of 0.06 mm per year, 0.05 mm per year, and 0.08 mm per year for stainless steel, cobalt chrome, and titanium alloy, respectively. The comparison between cemented molded metal-backed and nonmetal-backed acetabular components was not matched, with 134 metal-backed and 99 nonmetal-backed components. Results showed linear wear rates of 0.011 mm per year in the metal-backed group and 0.08 mm per year in the nonmetal-backed group. Results were statistically significant. These results indicate that the metal composition of the femoral bearing surface has minimal, if any, effect on the linear polyethylene wear rate. The method of polyethylene fabrication and the use of metal backing had a significant effect on the polyethylene wear rate in these patient groups. These results suggest that the compression-molded all-polyethylene acetabular component may be optimal for reducing polyethylene wear in total hip arthroplasty.
引用
收藏
页码:7 / 13
页数:7
相关论文
共 50 条
  • [21] CONSERVATIVE TOTAL HIP-ARTHROPLASTY
    CAPELLO, WN
    MISAMORE, GW
    TRANCIK, TM
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1982, 13 (04) : 833 - 842
  • [22] PERIPROSTHETIC OSTEOLYSIS IN TOTAL HIP-ARTHROPLASTY - THE ROLE OF PARTICULATE WEAR DEBRIS
    MALONEY, WJ
    SMITH, RL
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1995, 77 (09): : 1448 - 1461
  • [23] GIRDLESTONE ARTHROPLASTY FOR INFECTED TOTAL HIP-ARTHROPLASTY
    BITTAR, ES
    PETTY, W
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1982, (170) : 83 - 87
  • [24] THE INFECTED HIP AFTER TOTAL HIP-ARTHROPLASTY
    CANNER, GC
    STEINBERG, ME
    HEPPENSTALL, RB
    BALDERSTON, R
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (09): : 1393 - 1399
  • [25] TOTAL HIP-ARTHROPLASTY IN THE HIGH DISLOCATED HIP
    MENDES, DG
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1981, 17 (01): : 57 - 57
  • [26] TREATMENT OF THE SEPTIC HIP WITH TOTAL HIP-ARTHROPLASTY
    BALDERSTON, RA
    HILLER, WDB
    IANNOTTI, JP
    PICKENS, GT
    BOOTH, RE
    GLUCKMAN, SJ
    BUCKLEY, RM
    ROTHMAN, RH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (221) : 231 - 237
  • [27] In Vivo Measurement of Polyethylene Wear in Cementless Total Hip Arthroplasty
    Roth, A.
    Sander, K.
    Layher, F.
    Babisch, J.
    Venbrocks, R.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2010, 77 (01) : 13 - 17
  • [28] Influence of polyethylene creep behavior on wear in total hip arthroplasty
    Penmetsa, JR
    Laz, PJ
    Petrella, AJ
    Rullkoetter, PJ
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2006, 24 (03) : 422 - 427
  • [29] ASSESSMENT OF INDICATIONS FOR TOTAL KNEE ARTHROPLASTY AND TOTAL HIP-ARTHROPLASTY
    MANCUSO, CA
    RANAWAT, CS
    FLYNN, WF
    CHARLSON, ME
    ARTHRITIS AND RHEUMATISM, 1992, 35 (09): : S320 - S320
  • [30] REVISION OF INFECTED TOTAL HIP-ARTHROPLASTY
    WEBER, FA
    LAUTENBACH, EEG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1986, (211) : 108 - 115