RELIABILITY OF THE ARTERIAL TO END-TIDAL CARBON-DIOXIDE GRADIENT IN MECHANICALLY VENTILATED PATIENTS WITH MULTISYSTEM TRAUMA

被引:49
|
作者
RUSSELL, GB [1 ]
GRAYBEAL, JM [1 ]
机构
[1] PENN STATE UNIV, COLL MED, DEPT ANESTHESIA, HERSHEY, PA USA
关键词
D O I
10.1097/00005373-199403000-00006
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The accuracy and reliability of the relationship between arterial and end-tidal carbon dioxide (PETCO(2) and Paco(2)), expressed as the gradient, P(a - ET)CO2, was assessed with 171 comparisons in nine mechanically ventilated trauma patients. The P(a - ET)CO2 was 14 +/- 11 mm Hg. (mean +/- standard deviation.) The positive correlation between Paco(2) (44 +/- 10 mm Hg) and PETCO(2) (30 +/- 10 mm Hg) for the study population (reflected by r = 0.64, p = 0.001; but r(2) = 0.41) indicated statistical significance, but only 40% of the changes reflected a linear relationship. Seventyeight percent of individual patients had significant correlations of Paco(2) and PETCO(2) (p < 0.02 to p < 0.001). Changes in PETCO(2) erroneously predicted the Paco(2) changes in 27% of comparisons with 15% false decreases and 12% false increases. Trends in P(a - ET)coa magnitude are not reliable, and concordant direction changes in PETCO(2) and Paco(2) are not assured.
引用
收藏
页码:317 / 322
页数:6
相关论文
共 50 条
  • [41] Correlation of end-tidal and arterial carbon-dioxide levels in critically Ill neonates and children
    Mehta, Hiren
    Kashyap, Rahul
    Trivedi, Sangita
    INDIAN JOURNAL OF CRITICAL CARE MEDICINE, 2014, 18 (12) : 833 - U73
  • [42] ARTERIAL TO END-TIDAL CARBON-DIOXIDE TENSION DIFFERENCE IN CHILDREN UNDER HALOTHANE ANESTHESIA
    VALENTIN, N
    LOMHOLT, B
    THORUP, M
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1982, 29 (01) : 12 - 15
  • [43] Utility of arterial to end-tidal carbon dioxide gradient as a severity index in critical care
    Hong, Kyung Sook
    Lee, Jae Gil
    Kim, Tae Yoon
    Lee, Jae-myeong
    Park, Hoonsung
    Lee, Hanyoung
    Yang, Na Rae
    Baik, Seung Min
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2025, 369 (03): : 326 - 333
  • [44] Arterial to end-tidal carbon dioxide tension difference in anaesthetized adults mechanically ventilated via a laryngeal mask or a cuffed oropharyngeal airway
    Casati, A
    Fanelli, G
    Cappelleri, G
    Albertin, A
    Anelati, D
    Magistris, L
    Torri, G
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 1999, 16 (08) : 534 - 538
  • [45] EEG AND END-TIDAL CARBON-DIOXIDE CONCENTRATION IN THE HYPERVENTILATION SYNDROME
    KESKIMAKI, I
    SAINIO, K
    SOVIJARVI, ARA
    STENBERG, D
    VILJANEN, A
    ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1980, 50 (5-6): : 496 - 501
  • [46] CALCULATION OF END-TIDAL CARBON-DIOXIDE FRACTIONS IN THE BAIN SYSTEM
    JONSSON, LO
    ZETTERSTROM, H
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1989, 33 (01) : 71 - 74
  • [47] END-TIDAL CARBON-DIOXIDE CONCENTRATION DURING CARDIOPULMONARY RESUSCITATION
    KOESTER, DR
    NEW ENGLAND JOURNAL OF MEDICINE, 1988, 319 (09): : 579 - 579
  • [48] COLORIMETRIC END-TIDAL CARBON-DIOXIDE MONITORING FOR TRACHEAL INTUBATION
    GOLDBERG, JS
    RAWLE, PR
    ZEHNDER, JL
    SLADEN, RN
    ANESTHESIA AND ANALGESIA, 1990, 70 (02): : 191 - 194
  • [49] FALSE-POSITIVES WITH THE END-TIDAL CARBON-DIOXIDE DETECTOR
    OFLAHERTY, D
    ADAMS, AP
    ANESTHESIA AND ANALGESIA, 1992, 74 (03): : 467 - 468
  • [50] END-TIDAL CARBON-DIOXIDE CONCENTRATION DURING CARDIOPULMONARY RESUSCITATION
    FALK, JL
    RACKOW, EC
    WEIL, MH
    NEW ENGLAND JOURNAL OF MEDICINE, 1988, 318 (10): : 607 - 611