Radiation therapy for stereotactic body radiation therapy in spine tumors: linac or robotic?

被引:3
|
作者
De Ornelas-Couto, Mariluz [1 ]
Bossart, Elizabeth [1 ]
Ly, Bevan [1 ]
Monterroso, Maria Irene [1 ]
Mihaylov, Ivaylo [1 ]
机构
[1] Univ Miami, Dept Radiat Oncol, Miami, FL 33156 USA
来源
关键词
SBRT; spine; CyberKnife; VMAT; IMRT;
D O I
10.1088/2057-1976/2/1/015012
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Stereotactic body radiotherapy (SBRT) is used for spine treatments as it precisely delivers high radiation dose to tumors in close proximity to organs-at-risk (OARs). The goal of this work is to evaluate dosimetric properties of SBRT for spinal treatments with linear accelerators and CyberKnife (CK). Materials and methods: Plans of 27 patients, treated with CK for spine tumors, were also retrospectively optimized for linac-based (LB) intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). One nine-field IMRT plan and five VMAT plans were generated for each patient. The LB target volumes were uniformly expanded by 0.1 cm to accommodate for the uncertainty in patient positioning. All plans were optimized to cover 90% of the target volumes with a prescription dose of 27 Gy in three fractions. If dose constraints to OARs were not met, the prescription dose was decreased to 24 Gy. Target dose conformity and falloff were evaluated with Paddick's conformity (CI) and gradient (GI) indices. Results: PTV expansion resulted in a 31.5% volume increase in the LB plans. The three full-arcs VMAT(VMAT_3full) plans resulted in the best average CI(0.820) compared to CK(0.758) with worst average from one half-arcs VMAT (VMAT_1half) plans (0.747). Dose falloff was also superior with the VMAT_3full plans with an average GI value of 3.596, in comparison to CK(3.786) and IMRT(4.447). In 6 cases CKplans were unable to meet OAR constraints and the prescription dose was decreased to 24 Gy, compared to only 2 for VMAT_3full. Conclusion: Regardless of the larger target volumes, LB plans were comparable to CK plans. Conformity of target doses of the VMAT_3full plans were better than CK in all cases and dose fall-off was better 23 of 27 plans. Dose to OARs were lower for CK, but constraints met for all plans. The use of VMAT would reduce the treatment time.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Stereotactic Body Radiation Therapy (SBRT) for Pediatric Bone Tumors
    Brown, L. C.
    Lester, R. A.
    Haddock, M. G.
    Sarkaria, J. N.
    Olivier, K. R.
    Arndt, C. A. S.
    Laack, N. N.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S71 - S71
  • [32] Hypofractionated Radiation Therapy vs Stereotactic Body Radiation Therapy for Ultra-Central Lung Tumors
    Song, R.
    Burrows, C.
    Nsouli, T.
    Alden, R.
    Bogart, J.
    Mix, M.
    JOURNAL OF THORACIC ONCOLOGY, 2023, 18 (11) : S527 - S528
  • [33] A Comparative Study of Robotic and Linac-Based Stereotactitc Body Radiation Therapy for Lumbar Spinal Tumors
    Bossart, E.
    Monterroso, M.
    Couto, M.
    Ly, B.
    Mihaylov, I.
    MEDICAL PHYSICS, 2014, 41 (06) : 306 - +
  • [34] Dosimetric Evaluation of Spine Stereotactic Body Radiation Therapy Setup Error
    Beninati, G.
    Barbiere, J.
    Ndlovu, A.
    MEDICAL PHYSICS, 2018, 45 (06) : E222 - E223
  • [35] Stereotactic Body Radiation Therapy for Spine Metastases From Hepatocellular Carcinoma
    Kim, T.
    Park, H.
    Oh, D.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S730 - S730
  • [36] Dosimetric Comparison of 3 Techniques for Spine Stereotactic Body Radiation Therapy
    Aljabab, S.
    Vellayappan, B.
    Vandervoort, E.
    Bahm, J.
    Zohr, R. E.
    Sinclair, J.
    Caudrelier, J. M.
    Szanto, J.
    Malone, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E74 - E75
  • [37] An Analysis of Knowledge Based Planning for Stereotactic Body Radiation Therapy of the Spine
    Foy, J.
    Marsh, R.
    Owen, D.
    Matuszak, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3353 - 3353
  • [38] Spine Stereotactic Body Radiation Therapy for Management of Spinal Cord Compression
    Yang, K.
    Balagamwala, E. H.
    Tariq, M. B.
    Suh, J. H.
    Angelov, L.
    Reddy, C. A.
    Djemil, T.
    Magnelli, A.
    Qi, P.
    Zhuang, T.
    Soeder, S.
    Chao, S. T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E64 - E65
  • [39] A Study on Variation of Intrafraction in Stereotactic Body Radiation Therapy for Spine Metastasis
    Cho, Y.
    Kim, J. H.
    Ahn, S. K.
    Lee, S. K.
    Cho, J. H.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2016, 96 (02): : E642 - E642
  • [40] Esophageal Damage From Thoracic Spine Stereotactic Body Radiation Therapy
    Cassidy, Vincent
    Amdur, Robert J.
    PRACTICAL RADIATION ONCOLOGY, 2022, 12 (05) : 392 - 396