A comparative analysis of the accuracy of implant master casts fabricated from two different transfer impression techniques

被引:4
|
作者
Patil, Rupali [1 ]
Kadam, Pankaj [1 ]
Oswal, Chetan
Patil, Seema [1 ]
Jajoo, Shweta [2 ]
Gachake, Arati [1 ]
机构
[1] Bharati Vidyapeeth Dent Coll, Dept Prosthodont, Pune, Maharashtra, India
[2] Bharati Vidyapeeth Dent Coll, Dept Pedodont, Pune, Maharashtra, India
关键词
Closed tray impressions; custom trays; implants; open tray impression; stock tray; stock tray impressions;
D O I
10.4103/2231-0762.178747
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim: This study evaluated and compared two impression techniques in terms of their dimensional accuracies to reproduce implant positions on working casts. Materials and Methods: A master model was designed to simulate a clinical situation. Impressions were made using four techniques: (1) Stock open tray (SOT) technique; (2) stock closed tray (SCT) technique; (3) custom open tray (COT) technique; and (3) custom closed tray (CCT) technique. Reference points on the hexagonal silhouette of the implant on master model and onto the analogs of the obtained master casts were compared after using the four impression techniques. Measurements were made using an optical microscope, capable of recording under 50x magnifications. The means and standard deviations of all the groups and subgroups were calculated and statically analyzed using analysis of variance (ANOVA) and Tukey's test. Results: The open tray impressions showed significantly less variation from the master model and all the techniques studied were comparable. Conclusion: All the techniques studied shown some distortion. COT showed the most accurate results of all the techniques.
引用
收藏
页码:142 / 148
页数:7
相关论文
共 50 条
  • [31] A Clinical Comparative Study of 3-Dimensional Accuracy between Digital and Conventional Implant Impression Techniques
    Alsharbaty, Mohammed Hussein M.
    Alikhasi, Marzieh
    Zarrati, Simindokht
    Shamshiri, Ahmed Reza
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2019, 28 (04): : E902 - E908
  • [32] Implant impression accuracy of parallel and non-parallel implants: a comparative in-vitro analysis of open and closed tray techniques
    Osman, Motaz S.
    Ziada, Hassan M.
    Abubakr, Neamat H.
    Suliman, Ahmed M.
    INTERNATIONAL JOURNAL OF IMPLANT DENTISTRY, 2019, 5 (1)
  • [33] Effect of core materials on the dimensional accuracy of casts made of two different silicone impression materials: An experimental study
    Farzin, Mitra
    Derafshi, Reza
    Giti, Rashin
    Kalantari, Mohammad-Hassan
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2020, 10 (02): : 196 - 204
  • [34] The effect of pouring time on the dimensional accuracy of casts made from different irreversible hydrocolloid impression materials
    Wadhwa, Supneet Singh
    Mehta, Richa
    Duggal, Nidhi
    Vasudeva, Kamlesh
    CONTEMPORARY CLINICAL DENTISTRY, 2013, 4 (03) : 313 - 318
  • [35] Evaluation of Implant Impression Accuracy Using Different Trays and Techniques with a 3D Superimposition Method
    Unsal, Gokce
    Caglar, Alper
    Tural, Mine
    Orhan, Metin
    Alkan, Ozer
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (04) : 595 - 602
  • [36] Fit of implant-supported fixed prostheses fabricated on master casts made from a dental stone and a dental plaster
    Wise, M
    JOURNAL OF PROSTHETIC DENTISTRY, 2001, 86 (05): : 532 - 538
  • [37] Influence of intraoral conditions on the accuracy of digital and conventional implant impression techniques for two-implant-supported fixed dental prostheses
    Ma, Yun
    Guo, Yong-qing
    Jiang, Lei
    Yu, Hao
    JOURNAL OF PROSTHODONTIC RESEARCH, 2023, 67 (04) : 633 - 640
  • [38] Comparative Evaluation of the Rigidity and Accuracy of Different Elastomeric Impression Materials with Open Tray Implant Level Impression Technique-An In vitro Study
    Aidasani, Ashwin N.
    Jain, Shailesh
    Hassan, Sahba
    Sharma, Anu
    Shanthi, C.
    Fere, Sandeep
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1262 - S1265
  • [39] Effect of Splinted and Nonsplinted Impression Techniques on the Accuracy of Fit of Fixed Implant Prostheses in Edentulous Patients: A Comparative Study
    Papaspyridakos, Panos
    Lal, Kunal
    White, George Shelby
    Weber, Hans-Peter
    Gallucci, German O.
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2011, 26 (06) : 1267 - 1272
  • [40] Comparative Analysis of Three Different Impression Techniques for Impression Defects and Dimensional Accuracy Using a Digital Intraoral Scanner for Fixed Partial Dentures: An In Vivo Study
    Khatuja, Neha G.
    Katiyar, Pratibha
    Tarannum, Fauzia
    Pandey, Kaushik Kumar
    Katiyar, Abhishek Kumar
    Afzal, Zoya
    Ali, Aman
    Roy, Ispita
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)