REFERENCE MATERIALS FOR USFDAS WHOLE-BODY COUNTING SYSTEM

被引:0
|
作者
BARATTA, EJ
机构
[1] U.S. Food and Drug Administration, Winchester, 01890-1152, MA
来源
关键词
D O I
10.1007/BF00322324
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The U.S. Food and Drug Administration (FDA) operates a whole-body counter at its's Winchester Engineering and Analytical Center (WEAC), Winchester, MA. This counter has been registered with the International Atomic Energy Agency (IAEA) and has been made available to others. The new requirements of the Nuclear Regulatory Commission (NRC) include internal dose exposure, using such a system. The whole-body counter performs thyroid scans for iodine-131 and also for iodine-125 and iodine-123. The latter requires thin-window germanium detectors (X-ray spectrometers). In addition, it has a large sodium iodine (Tl) crystal for whole body scans. One of the problems has been developing reference standards for energy and efficiency calibrations. Up to recently, only phantoms have been available to which the radioactive solution must be added. Lately, the Department of Energy has developed a ''loan'' program of phantoms containing specific radioactive isotopes in various configurations. This is expected to be added to this program to confirm the measurements. Software has also been developed which will calculate a 50 year dose commitment as required by the NRC for exposures. The use of these reference materials to assure that the system is in calibration is discussed.
引用
收藏
页码:189 / 192
页数:4
相关论文
共 50 条
  • [41] CURRENT STATUS OF WHOLE-BODY COUNTING AS A MEANS TO DETECT AND QUANTIFY PREVIOUS EXPOSURES TO RADIOACTIVE MATERIALS
    TOOHEY, R
    PALMER, E
    ANDERSON, L
    BERGER, C
    COHEN, N
    EISELE, G
    WACHHOLZ, B
    BURR, W
    HEALTH PHYSICS, 1991, 60 : 7 - 42
  • [42] MEASUREMENT OF WHOLE-BODY CELLULAR AND COLLAGEN NITROGEN, POTASSIUM, AND OTHER ELEMENTS BY NEUTRON-ACTIVATION AND WHOLE-BODY COUNTING
    JAMES, HM
    FABRICIUS, PJ
    DYKES, PW
    JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 1987, 11 (05) : S48 - S50
  • [43] UTILITY OF BOTTLE PHANTOM IN CALIBRATION OF WHOLE-BODY COUNTING SYSTEMS
    GUPTA, NK
    GUPTA, MM
    BHOLA, GC
    JOURNAL OF NUCLEAR BIOLOGY AND MEDICINE, 1976, 20 (03): : 132 - 134
  • [44] FOLLOW-UP OF THYROID CARCINOMA BY WHOLE-BODY COUNTING
    EDMONDS, CJ
    SMITH, T
    BARNABY, CF
    BRITISH JOURNAL OF RADIOLOGY, 1970, 43 (516): : 868 - &
  • [45] Evaluation of whole-body counting capabilities based on ICRP limits
    Dantas, BM
    Bertelli, L
    Lipsztein, JL
    RADIATION PROTECTION DOSIMETRY, 2000, 89 (3-4) : 255 - 258
  • [46] FUTURE USE OF LOW-LEVEL WHOLE-BODY COUNTING
    KOEPPE, P
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1979, 4 (02): : 146 - 146
  • [47] LINEAR SCANNING DEVICE FOR WHOLE-BODY COUNTING AND PROFILE SCANNING
    SORENSON.JA
    TYSON, IB
    PHYSICS IN MEDICINE AND BIOLOGY, 1970, 15 (01): : 161 - &
  • [48] WHOLE-BODY COUNTING STUDIES USING CESIUM-132
    GRUNDY, RD
    SARGENT, TW
    JOURNAL OF NUCLEAR MEDICINE, 1966, 7 (09) : 676 - &
  • [49] Improvement to whole-body counting procedures at nuclear power plants
    Kong, Tae Young
    Kim, Hee Geun
    RADIATION PROTECTION DOSIMETRY, 2009, 133 (02) : 89 - 96
  • [50] EXAMINATION OF IRON-METABOLISM BY WHOLE-BODY COUNTING IN MICE
    DEZSO, G
    NAGY, G
    CSABA, B
    KOSA, I
    ACTA BIOCHIMICA ET BIOPHYSICA HUNGARICA, 1973, 8 (03) : 192 - 192