MEASUREMENT OF FREQUENCY-RESPONSE IN SHORT THERMOCOUPLE WIRES

被引:9
|
作者
FORNEY, LJ
MEEKS, EL
MA, J
FRALICK, GC
机构
[1] GEORGIA INST TECHNOL,MICROELECTR RES CTR,ATLANTA,GA 30332
[2] GEORGIA INST TECHNOL,SCH MECH ENGN,ATLANTA,GA 30332
[3] NASA,LEWIS RES CTR,RES SENSOR TECHNOL BRANCH,CLEVELAND,OH 44135
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1993年 / 64卷 / 05期
关键词
D O I
10.1063/1.1144080
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Experimental measurements are made for the steady-state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10% with the theoretical predictions of Fralick and Forney (1992) for a laser-heated junction with no bead. This is accomplished by choosing a natural frequency omega(n) for the wire data to correlate the first-order response at large gas temperature frequencies. Moreover, it is found that a large bead size (roughly twice the wire diameter) will increase the amplitude ratio at low frequencies and distort the phase angle. In the latter case, it is necessary to increase the thermocouple wire length by 20% in the theory to correlate the data when the junctions have beads (silver soldered).
引用
收藏
页码:1280 / 1286
页数:7
相关论文
共 50 条
  • [31] PRACTICAL APPLICATION OF THE RAPID FREQUENCY SWEEP TECHNIQUE FOR STRUCTURAL FREQUENCY-RESPONSE MEASUREMENT
    WHITE, RG
    PINNINGTON, RJ
    AERONAUTICAL JOURNAL, 1982, 86 (855): : 179 - 199
  • [32] MEASUREMENT OF FREQUENCY-RESPONSE OF A PIEZOELECTRIC TRANSDUCER USING AN ACOUSTOOPTIC MODULATOR
    MAN, C
    CEREZ, P
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1980, 13 (02): : 157 - 159
  • [33] ON THE FREQUENCY-RESPONSE OF LOUDSPEAKERS
    BRUNEAU, AM
    BRUNEAU, M
    ACUSTICA, 1980, 44 (04): : 308 - 313
  • [34] FREQUENCY-RESPONSE TESTING
    KERLIN, TW
    NUCLEAR SAFETY, 1967, 8 (04): : 339 - &
  • [35] FREQUENCY-RESPONSE OF PNEUMOTACHOGRAPHS
    PESLIN, R
    MORINETL.J
    DUVIVIER, C
    BULLETIN DE PHYSIO-PATHOLOGIE RESPIRATOIRE, 1972, 8 (06): : 1363 - 1376
  • [36] ACUTANCE AND FREQUENCY-RESPONSE
    JAKOBSCHUK, A
    JOURNAL OF PHOTOGRAPHIC SCIENCE, 1983, 31 (03): : 129 - 132
  • [37] FREQUENCY-RESPONSE ANALYZER
    SRIVATSA, K
    PARTHA, R
    SRIDHARMURTHY, SL
    ELECTRONICS & WIRELESS WORLD, 1984, 90 (1578): : 44 - 45
  • [38] HEADPHONE FREQUENCY-RESPONSE
    SCHOENWALD, DJ
    QST, 1983, 67 (08) : 49 - 49
  • [39] FREQUENCY-RESPONSE OF DISKS
    DAVIES, SW
    WIRELESS WORLD, 1972, 78 (1437): : 116 - &
  • [40] FREQUENCY-RESPONSE IN PHOTOMULTIPLIERS
    WOLPERT, HD
    PHOTONICS SPECTRA, 1983, 17 (12) : 71 - &