MEASUREMENT OF FREQUENCY-RESPONSE IN SHORT THERMOCOUPLE WIRES

被引:9
|
作者
FORNEY, LJ
MEEKS, EL
MA, J
FRALICK, GC
机构
[1] GEORGIA INST TECHNOL,MICROELECTR RES CTR,ATLANTA,GA 30332
[2] GEORGIA INST TECHNOL,SCH MECH ENGN,ATLANTA,GA 30332
[3] NASA,LEWIS RES CTR,RES SENSOR TECHNOL BRANCH,CLEVELAND,OH 44135
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1993年 / 64卷 / 05期
关键词
D O I
10.1063/1.1144080
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Experimental measurements are made for the steady-state frequency response of a supported thermocouple wire. In particular, the effects of axial heat conduction are demonstrated for both a supported one material wire (type K) and a two material wire (type T) with unequal material properties across the junction. The data for the amplitude ratio and phase angle are correlated to within 10% with the theoretical predictions of Fralick and Forney (1992) for a laser-heated junction with no bead. This is accomplished by choosing a natural frequency omega(n) for the wire data to correlate the first-order response at large gas temperature frequencies. Moreover, it is found that a large bead size (roughly twice the wire diameter) will increase the amplitude ratio at low frequencies and distort the phase angle. In the latter case, it is necessary to increase the thermocouple wire length by 20% in the theory to correlate the data when the junctions have beads (silver soldered).
引用
收藏
页码:1280 / 1286
页数:7
相关论文
共 50 条
  • [1] FREQUENCY-RESPONSE OF FINE WIRE THERMOCOUPLE
    PETIT, C
    GAJAN, P
    LECORDIER, JC
    PARANTHOEN, P
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1982, 15 (07): : 760 - 764
  • [2] 2 WIRE THERMOCOUPLE - FREQUENCY-RESPONSE IN CONSTANT FLOW
    FORNEY, LJ
    FRALICK, GC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1994, 65 (10): : 3252 - 3257
  • [3] FREQUENCY-RESPONSE OF A THERMOCOUPLE WIRE - EFFECTS OF AXIAL CONDUCTION
    FORNEY, LJ
    FRALICK, GC
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 1991, 18 (04) : 531 - 546
  • [4] 3-WIRE THERMOCOUPLE - FREQUENCY-RESPONSE IN CONSTANT FLOW
    FORNEY, LJ
    FRALICK, GC
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (05): : 3331 - 3336
  • [5] ON THE MEASUREMENT OF VIOLIN FREQUENCY-RESPONSE
    DUNNWALD, H
    ACUSTICA, 1982, 51 (06): : 281 - 287
  • [6] A NOTE ON FREQUENCY-RESPONSE MEASUREMENT
    DOUCE, JL
    IEE PROCEEDINGS-D CONTROL THEORY AND APPLICATIONS, 1986, 133 (04): : 189 - 190
  • [7] FREQUENCY-RESPONSE OF A SUPPORTED THERMOCOUPLE WIRE - EFFECTS OF AXIAL CONDUCTION
    FRALICK, GC
    FORNEY, LJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1993, 64 (11): : 3236 - 3244
  • [8] THE MEASUREMENT OF THE FREQUENCY-RESPONSE OF A PHOTODIODE AND AMPLIFIER USING AN OPTOMECHANICAL FREQUENCY-RESPONSE CALIBRATOR
    ROBINSON, SP
    BACON, DR
    MOSS, BC
    MEASUREMENT SCIENCE AND TECHNOLOGY, 1990, 1 (11) : 1184 - 1187
  • [9] FREQUENCY-RESPONSE OF SHORT PRESSURE PROBES
    NYLAND, TW
    ENGLUND, DR
    ANDERSON, RC
    INSTRUMENTS & CONTROL SYSTEMS, 1973, 46 (08): : 27 - 29
  • [10] FREQUENCY-RESPONSE MEASUREMENT FOR A RHEOSIGNAL GENERATOR
    DUBROVSKII, IA
    MEASUREMENT TECHNIQUES USSR, 1989, 32 (02): : 183 - 184