EVALUATION OF A SAMPLING AND ANALYSIS METHOD FOR DETERMINATION OF POLYHALOGENATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN AMBIENT AIR

被引:11
|
作者
HARLESS, RL [1 ]
LEWIS, RG [1 ]
MCDANIEL, DD [1 ]
GIBSON, JF [1 ]
DUPUY, AE [1 ]
机构
[1] US EPA,ENVIRONM CHEM LAB,BAY ST LOUIS,MS 39529
关键词
D O I
10.1016/0045-6535(92)90148-K
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
General Metals Works PS-1 PUF air samplers and an analytical method based on high resolution gas chromatography - high resolution mass spectrometry (HRGC-HRMS) were evaluated for determination of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDDs/PCDFs), polybrominated dibenzo-p-dioxins and dibenzofurans (PBDDs/PBDFs) and bromo/chloro dibenzo-p-dioxins and dibenzofurans (BCDDs/BCDFs) in ambient air. Dilute solutions of these compounds and C-13(12)-1,2,3,4-TCDD were used to spike the filters of PS-1 air samplers which were then operated 24 hr to sample 350-400 m3 ambient air. After sampling, each quartz-fiber filter and polyurethane foam (PUF) were spiked with C-13(12)-labeled PCDD, PCDF, PBDD, and PBDF internal standards before separate Soxhlet extractions with benzene. The extracts were subjected to an acid/base clean-up procedure followed by clean-up on microcolumns of silica gel, alumina, and carbon and then analyzed by HRGC-HRMS. Results derived from this study indicated the PS-1 ambient air samplers and the analytical procedures were very efficient and that pg/m3 and sub-pg/m3 levels of total PCDDs/PCDFs, PBDDs/PBDFs, BCDDs/BCDFs, and 2,3,7,8-substituted congeners could be accurately measured. Background levels of these compounds in the ambient air were also determined. Total PCDDs, PCDFs, TBDFs, and PeBDFs were detected in a low concentration range of 0.3 to 3.0 pg/m3.
引用
收藏
页码:1317 / 1322
页数:6
相关论文
共 50 条
  • [1] DETERMINATION OF POLYHALOGENATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN SIMULATED INCINERATOR EMISSIONS
    RIGGS, K
    REUTHER, J
    WHITE, J
    PITTS, G
    CHEMOSPHERE, 1992, 25 (7-10) : 1415 - 1420
  • [2] Polyhalogenated dibenzo-p-dioxins and dibenzofurans in the exhaust air during textile processings
    Sedlak, D
    Dumler-Gradl, R
    Thoma, H
    Vierle, O
    CHEMOSPHERE, 1998, 37 (9-12) : 2071 - 2076
  • [3] ANALYSIS OF SEWAGE-SLUDGE FOR POLYHALOGENATED DIBENZO-P-DIOXINS, DIBENZOFURANS, AND DIPHENYLETHERS
    HAGENMAIER, H
    SHE, J
    BENZ, T
    DAWIDOWSKY, N
    DUSTERHOFT, L
    LINDIG, C
    CHEMOSPHERE, 1992, 25 (7-10) : 1457 - 1462
  • [4] PECULIARITIES OF THE TOXICITY OF POLYHALOGENATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN ANIMALS AND MAN
    NEUBERT, D
    CHEMOSPHERE, 1991, 23 (11-12) : 1869 - 1893
  • [5] COMPARATIVE MOLECULAR-FIELD ANALYSIS OF POLYHALOGENATED DIBENZO-P-DIOXINS, DIBENZOFURANS, AND BIPHENYLS
    WALLER, CL
    MCKINNEY, JD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 112 - MEDI
  • [6] COMPARATIVE MOLECULAR-FIELD ANALYSIS OF POLYHALOGENATED DIBENZO-P-DIOXINS, DIBENZOFURANS, AND BIPHENYLS
    WALLER, CL
    MCKINNEY, JD
    JOURNAL OF MEDICINAL CHEMISTRY, 1992, 35 (20) : 3660 - 3666
  • [7] QUANTITATIVE METHOD FOR THE DETERMINATION OF FEMTOGRAM AMOUNTS OF POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN OUTDOOR AIR
    OEHME, M
    MANO, S
    MIKALSEN, A
    KIRSCHMER, P
    CHEMOSPHERE, 1986, 15 (05) : 607 - 617
  • [8] Dry deposition of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) in ambient air
    Shih, ML
    Lee, WS
    Chang-Chien, GP
    Wang, LC
    Hung, CY
    Lin, KC
    CHEMOSPHERE, 2006, 62 (03) : 411 - 416
  • [9] Statistical investigation of polychlorinated dibenzo-p-dioxins and dibenzofurans in the ambient air of Houston, Texas
    Raun, LH
    Correa, O
    Rifai, H
    Suarez, M
    Koenig, L
    CHEMOSPHERE, 2005, 60 (07) : 973 - 989
  • [10] Distribution of polychlorinated dibenzo-p-dioxins and dibenzofurans in ambient air of different regions in China
    Chen, Tong
    Li, Xiaodong
    Yan, Jianhua
    Lu, Shengyong
    Cen, Kefa
    ATMOSPHERIC ENVIRONMENT, 2011, 45 (36) : 6567 - 6575