共 50 条
GADOTERIDOL DOSE DEPENDENCE IN MR-IMAGING OF A LIVER-ABSCESS MODEL
被引:8
|作者:
RUNGE, VM
KIRSCH, JE
WOOLFOLK, C
BRACK, MA
GARNEAU, RA
机构:
[1] Magnetic Resonance Imaging and Spectroscopy Center, University of Kentucky, Lexington, Kentucky, 40536-0098, Rm 109
来源:
关键词:
CONTRAST ENHANCEMENT;
CONTRAST MEDIA;
EXPERIMENTAL STUDIES;
GADOLINIUM;
LIVER;
INFECTION;
NECROSIS;
D O I:
10.1002/jmri.1880040320
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
A necrotic liver abscess model was studied with magnetic resonance (MR) imaging at 1.5 T before and after intravenous administration of gadoteridol at doses of 0.1, 0.25, and 0.5 mmol/kg in 24 rabbits. Enhancement characteristics and lesion delineation were assessed with both breath-hold and non-breath-hold imaging techniques. Lesion delineation. as assessed both by signal intensity measurements and evaluations by two image readers blinded to imaging technique. was greatest on high-dose (0.5 mmol/kg) breath-hold images. Lesion rim enhancement was seen consistently only on postcontrast images obtained at a dose of 0.5 mmol/kg and progressed with time after injection of contrast material.
引用
收藏
页码:343 / 350
页数:8
相关论文