THE PRIMARY ATTENUATION COEFFICIENT OF A P(66)+BE(40) NEUTRON THERAPY BEAM

被引:0
|
作者
SCHREUDER, AN
JONES, DTL
PISTORIUS, S
GROENEWALD, WA
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The concept of primary and scattered dose components of a radiotherapy beam is commonly used in radiotherapy planning. Four different methods which have been used for photon beams were applied to determine the primary dose linear attenuation coefficient in water (mu0) in a p(66)+Be(40) neutron therapy beam. They were: (a) the extrapolation of measured tissue-maximum ratios to zero field size, (b) linear attenuation measurements, (c) dose measurements in phantom with and without a central axis attenuator, and (d) fitting a central axis kerma model, based on convolution techniques, to measured percentage depth dose data. The mu0 values obtained agree well with each other and vary between 0.071 cm-1 and 0.075 cm-1.
引用
收藏
页码:411 / 415
页数:5
相关论文
共 50 条
  • [41] DETERMINATION OF AMPLITUDE ATTENUATION COEFFICIENT OF PRIMARY ELECTRON WAVE FROM DEPENDENCE OF DIFFRACTION BEAM INTENSITY OF INCIDENT ELECTRON-ENERGY
    ZYRYANOV, GK
    KNYAZEV, SA
    VESTNIK LENINGRADSKOGO UNIVERSITETA SERIYA FIZIKA KHIMIYA, 1975, (01): : 48 - 52
  • [42] Beam shaping assembly design of Li(p,n) neutron source with a rotating target for boron neutron capture therapy
    Qiao, Zhaopeng
    Ma, Baolong
    Rong, Bo
    Jiang, Quanxu
    Wang, Sheng
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1052
  • [43] Neutron Beam Attenuation through Semiconductor Devices during SEU Testing
    Wender, S. A.
    O'Donnell, J. M.
    Zavorka, L.
    Bhuva, B. L.
    2019 IEEE INTERNATIONAL RELIABILITY PHYSICS SYMPOSIUM (IRPS), 2019,
  • [44] Directional characteristics of neutrons from the p(66)/Be(40) reaction
    Division of Medical Radiation, National Accelerator Centre, P. O. Box 72, Faure 7131, South Africa
    MED. PHYS., 5 (597-600):
  • [45] DIRECTIONAL CHARACTERISTICS OF NEUTRONS FROM THE P(66)/BE(40) REACTION
    SYMONS, JE
    JONES, DTL
    BROOKS, FD
    NCHODU, MR
    BUFFLER, A
    ALLIE, MS
    OLIVER, MJ
    MEDICAL PHYSICS, 1995, 22 (05) : 597 - 599
  • [46] Bessel-Beam Interferometry for Turbidity With Refractive Index, Attenuation Coefficient, and Loss
    Pandey, Amit
    Mondal, Samir K.
    IEEE SENSORS LETTERS, 2022, 6 (08)
  • [47] Investigations of the attenuation coefficient of a narrow-bandwidth pulsed laser beam in water
    Bai, Jianhui
    Liu, Juan
    Huang, Yi
    Liu, Yinan
    Sun, Lu
    Liu, Dahe
    Fry, E. S.
    APPLIED OPTICS, 2007, 46 (27) : 6804 - 6808
  • [48] Particulate beam attenuation coefficient, bacteria abundance and production in marine nearshore waters
    Montes-Hugo, Martin A.
    Reynolds, Rick A.
    Vernet, Maria
    Stramski, Dariusz
    Wright, Vanessa
    COASTAL OCEAN REMOTE SENSING, 2007, 6680
  • [49] Calculating irradiance penetration into water bodies from the measured beam attenuation coefficient
    Arst, H
    Maekivi, S
    Lukk, T
    Herlevi, A
    LIMNOLOGY AND OCEANOGRAPHY, 1997, 42 (02) : 379 - 385
  • [50] Neutron beam therapy targets brain cancer
    Kmietowicz, Z
    BRITISH MEDICAL JOURNAL, 1998, 317 (7167): : 1176 - 1176