THE PRIMARY ATTENUATION COEFFICIENT OF A P(66)+BE(40) NEUTRON THERAPY BEAM

被引:0
|
作者
SCHREUDER, AN
JONES, DTL
PISTORIUS, S
GROENEWALD, WA
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The concept of primary and scattered dose components of a radiotherapy beam is commonly used in radiotherapy planning. Four different methods which have been used for photon beams were applied to determine the primary dose linear attenuation coefficient in water (mu0) in a p(66)+Be(40) neutron therapy beam. They were: (a) the extrapolation of measured tissue-maximum ratios to zero field size, (b) linear attenuation measurements, (c) dose measurements in phantom with and without a central axis attenuator, and (d) fitting a central axis kerma model, based on convolution techniques, to measured percentage depth dose data. The mu0 values obtained agree well with each other and vary between 0.071 cm-1 and 0.075 cm-1.
引用
收藏
页码:411 / 415
页数:5
相关论文
共 50 条
  • [1] EVALUATION OF KERMA RATIOS IN A P(66)/BE(40) NEUTRON THERAPY BEAM
    SYMONS, JE
    JONES, DTL
    MEDICAL PHYSICS, 1995, 22 (01) : 23 - 24
  • [2] TISSUE-MAXIMUM RATIOS FOR A P(66)+BE(40) NEUTRON THERAPY BEAM
    YUDELEV, M
    SCHREUDER, AN
    JONES, DTL
    RADIATION PROTECTION DOSIMETRY, 1992, 44 (1-4) : 417 - 420
  • [3] A QUALITY ASSESSMENT OF THE EFFECTS OF A HYDROGENOUS FILTER ON A P(66)BE(40) NEUTRON BEAM
    SLABBERT, JP
    BINNS, PJ
    JONES, HL
    HOUGH, JH
    BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (743): : 989 - 994
  • [4] THE EFFECT OF MISSING BACKSCATTER ON THE DOSE DISTRIBUTION OF A P(66)BE(49) NEUTRON THERAPY BEAM
    AWSCHALOM, M
    ROSENBERG, I
    TENHAKEN, RK
    MEDICAL PHYSICS, 1982, 9 (04) : 559 - 562
  • [5] BROAD BEAM ATTENUATION COEFFICIENT
    ALASTI, H
    CUNNINGHAM, JR
    MEDICAL PHYSICS, 1986, 13 (05) : 779 - 779
  • [6] NEUTRON FLUENCE AND KERMA SPECTRA OF A P(66)/BE(40) CLINICAL SOURCE
    JONES, DTL
    SYMONS, JE
    FULCHER, TJ
    BROOKS, FD
    NCHODU, MR
    ALLIE, MS
    BUFFLER, A
    OLIVER, MJ
    MEDICAL PHYSICS, 1992, 19 (05) : 1285 - 1291
  • [7] KERMA TRANSMISSION THROUGH STEEL FOR A P(66)BE(49) NEUTRON BEAM - AN UPDATE
    TENHAKEN, RK
    AWSCHALOM, M
    ROSENBERG, I
    HEALTH PHYSICS, 1983, 44 (03): : 277 - 281
  • [8] Need to augment the high-LET characteristics of a p(66)/Be neutron beam
    Slabbert, JP
    Theron, T
    Jones, DTL
    Schmitt, G
    ADVANCES IN NEUTRON CAPTURE THERAPY, VOLS I AND II: VOL I: MEDICINE AND PHYSICS, VOL II: CHEMISTRY AND BIOLOGY, 1997, 1132 : B553 - B556
  • [9] KERMA TRANSMISSION THROUGH VARIOUS MATERIALS FOR A P(66)BE(49) NEUTRON BEAM
    AWSCHALOM, M
    HREJSA, A
    ROSENBERG, I
    TENHAKEN, RK
    HEALTH PHYSICS, 1981, 41 (01): : 184 - 187
  • [10] VARIOUS ASPECTS OF ATTENUATION COEFFICIENT OF A NEUTRON MONITOR
    RAUBENHEIMER, BC
    STOKER, PH
    JOURNAL OF GEOPHYSICAL RESEARCH, 1974, 79 (34): : 5069 - 5076