CENTRALIZED PREPARATION OF HAZARDOUS DRUGS - A CHOICE BETWEEN ISOLATOR AND LAMINAR AIR-FLOW

被引:8
|
作者
LARROUTUROU, P
HUCHET, J
TAUGOURDEAU, MC
机构
[1] Department of Pharmacy, Saint-Joseph Hospital, Paris Cedex, 75674
关键词
ANTINEOPLASTIC AGENTS; COST AND COST ANALYSIS; DRUG COMPOUNDING; EQUIPMENT AND SUPPLIES; ISOLATOR; LAMINAR AIR-FLOW HOOD;
D O I
10.1007/BF01962692
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
In 1987, the manager of the Saint-Joseph Hospital (Paris, France) requested a reorganization of cytotoxic drug preparation. Protection for staff who handle hazardous drugs was the main concern. The conclusions drawn from a first analysis emphasize the advantages of a centralized reconstitution unit against a decentralized system. Subsequently, a workload study and an economic study (investment, maintenance, supplies, staff costs, comparative balance sheet and a 5-year simulation) were carried out, but to choose between a laminar airflow in aseptic room and an isolator in a conventional room. The selected isolator is the first of the conception: the central half-suit uses as a server, and four sleeves located on one side allow two technicians to work in a sterile and closed area without sterile garments.
引用
收藏
页码:88 / 92
页数:5
相关论文
共 50 条
  • [21] RELATIONSHIP BETWEEN SITES OF AIR-FLOW LIMITATION AND SEVERITY OF CHRONIC AIR-FLOW OBSTRUCTION
    FAIRSHTER, RD
    WILSON, AF
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1981, 123 (01): : 3 - 7
  • [22] INTERACTION BETWEEN AIR-FLOW AND WAVES
    KONONKOVA, GE
    POBORCHAYA, LV
    IZVESTIYA AKADEMII NAUK SSSR FIZIKA ATMOSFERY I OKEANA, 1974, 10 (05): : 552 - 556
  • [23] Implementing a multiple‐isolator unit for centralized preparation of cytotoxic drugs in a cancer center pharmacy
    Jean‐Louis Cazin
    Patricia Gosselin
    Pharmacy World and Science, 1999, 21 : 177 - 183
  • [24] IS LAMINAR AIR-FLOW NECESSARY FOR PROPHYLAXIS AGAINST WOUND-INFECTION
    LAUFMAN, H
    MEDICAL INSTRUMENTATION, 1976, 10 (06): : 269 - 274
  • [25] TESTING OF LAMINAR AIR-FLOW UNITS BY PARTICLE COUNTING AND BY MICROBIAL METHODS
    ASLUND, B
    OLSON, OT
    ACTA PHARMACEUTICA SUECICA, 1976, 13 (5-6): : 469 - 474
  • [26] The effect of laminar air-flow on the results of Austin-Moore hemiarthroplasty
    Kakwani, R. G.
    Yohannan, D.
    Wahab, K. H. A.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (07): : 820 - 823
  • [27] USE OF LAMINAR AIR-FLOW PORTABLE FILTER IN ASTHMATIC-CHILDREN
    VILLAVECES, JW
    ROSENGREN, H
    EVANS, J
    ANNALS OF ALLERGY, 1977, 38 (06): : 400 - 404
  • [28] LAMINAR AIR-FLOW VERSUS BARRIER NURSING IN MARROW TRANSPLANT RECIPIENTS
    MAHMOUD, HK
    SCHAEFER, UW
    SCHUNING, F
    SCHMIDT, CG
    BAMBERG, M
    HARALAMBIE, E
    LINZENMEIER, G
    HANTSCHKE, D
    GROSSEWILDE, H
    LUBOLDT, W
    RICHTER, HJ
    BLUT, 1984, 49 (05): : 375 - 381
  • [29] USE OF A LAMINAR AIR-FLOW ISOLATION SYSTEM FOR TREATMENT OF MAJOR BURNS
    DEMLING, RH
    PEREA, A
    MALY, J
    MOYLAN, JA
    JARRETT, F
    BALISH, E
    AMERICAN JOURNAL OF SURGERY, 1978, 136 (03): : 375 - 378
  • [30] Implementing a multiple-isolator unit for centralized preparation of cytotoxic drugs in a cancer center pharmacy
    Cazin, JL
    Gosselin, P