ANALYSIS OF WIND TURBINE GROUNDING SYSTEMS IN TERMS OF TOUCH AND STEP VOLTAGES

被引:0
|
作者
Koksal, Cagri [1 ]
Gul, Omer [1 ]
机构
[1] Istanbul Tech Univ, Elect Elect Fac, TR-34469 Maslak, Turkey
关键词
Touch voltage; step voltage; wind turbine; grounding;
D O I
暂无
中图分类号
P75 [海洋工程];
学科分类号
0814 ; 081505 ; 0824 ; 082401 ;
摘要
Power generation from renewable resources is increasingly growing. The numbers of wind turbines and wind farms are increasing as well. Wind turbines and wind farms require grounding systems in order to protect the living creatures and turbine components from fault current and lightning current. This study uses grounding systems consisting of conductors and electrodes with different and asymmetric depths of embedment as well as a non-homogenous two-layer soil model. By employing this model, it examines the effect of the reinforcement of the grounding system of a wind turbine on the step and touch voltages. Then, it examines the grounding system of a wind farm consisting of several wind turbines.
引用
收藏
页码:1867 / 1872
页数:6
相关论文
共 50 条
  • [31] Transient Characteristic of an Actual Wind Turbine Grounding System
    Yamamoto, Kazuo
    Sumi, Shinichi
    Yanagawa, Shunichi
    2013 ASIA-PACIFIC SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY (APEMC), 2013,
  • [32] STRUCTURAL DYNAMIC ANALYSIS OF WIND TURBINE SYSTEMS
    THRESHER, RW
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 1982, 104 (02): : 89 - 95
  • [33] Evaluation of sustainability of microgrid grounding grid design under varying soil conditions through estimation of touch, step voltages and novel methods of earthing
    Bhatia, Krishnav
    Darji, Pranav B.
    Jariwala, Hitesh R.
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2020, 14 (05) : 621 - 632
  • [34] Bare versus insulated conductors for improving the lightning response of interconnected wind turbine grounding systems
    Alipio, Rafael
    De Conti, Alberto
    Duarte, Naiara
    de Barros, Maria Teresa Correia
    ELECTRIC POWER SYSTEMS RESEARCH, 2021, 197
  • [35] A Simplified Model of Wind Turbine for Lightning Transient Analysis as Influenced by Structure of Grounding System
    Zalhaf, A. S.
    Ahmed, Mahmoud
    Ookawara, S.
    Abdel-Salam, Mazen
    2018 5TH INTERNATIONAL CONFERENCE ON ELECTRIC POWER AND ENERGY CONVERSION SYSTEMS (EPECS), 2018,
  • [36] Reduced Complexity Estimation of Neutral Voltages in Terms of Grounding Impedances via Phasor Interpolation
    Correa, Henrique P.
    Vieira, Flavio H. T.
    De Almeida, Maria Leonor S.
    IEEE ACCESS, 2020, 8 : 195946 - 195954
  • [37] Measurements of touch and step voltages adopting multi current auxiliary electrodes
    Parise, G
    Grasselli, U
    Iaconelli, R
    IAS 2000 - CONFERENCE RECORD OF THE 2000 IEEE INDUSTRY APPLICATIONS CONFERENCE, VOLS 1-5, 2000, : 3187 - 3193
  • [38] Reduced complexity estimation of neutral voltages in terms of grounding impedances via phasor interpolation
    Corrêa, Henrique P.
    Vieira, Flávio H. T.
    De Almeida, Maria Leonor S.
    IEEE Access, 2020, 8 : 195946 - 195954
  • [39] Simulation Model of Unsymmetrically - Shaped Grounding Grids for Investigation of the Touch Voltages during Lightning Stroke
    Dimitrova, Rositsa
    Vasileva, Margreta
    Yordanova, Marinela
    Ivanova, Milena
    2018 20TH INTERNATIONAL SYMPOSIUM ON ELECTRICAL APPARATUS AND TECHNOLOGIES (SIELA), 2018,
  • [40] Using interpolation method to estimation step and touch voltage in grounding system
    Sikora, Roman
    Markiewicz, Przemyslaw
    Maczka, Mariusz
    Pawlowski, Stanislaw
    Plewako, Jolanta
    PRZEGLAD ELEKTROTECHNICZNY, 2023, 99 (02): : 263 - 266