Extraction and cleansing of data for a non-targeted analysis of high-resolution mass spectrometry data of wastewater

被引:11
|
作者
Verkh, Yaroslav [1 ]
Rozman, Marko [1 ,2 ]
Petrovic, Mira [1 ,3 ]
机构
[1] Catalan Inst Water Res ICRA, Carrer Emili Grahit 101, Girona 17003, Spain
[2] Rudjer Boskovic Inst, Bijenicka Cesta 54, Zagreb 10000, Croatia
[3] Catalan Inst Res & Adv Studies ICREA, Passeig Lluis Co 23, Barcelona 08010, Spain
来源
METHODSX | 2018年 / 5卷
基金
欧盟地平线“2020”;
关键词
Water screening; Molecular formula prediction; R; MZmine;
D O I
10.1016/j.mex.2018.04.008
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
We provide a workflow to extract unidentified signals from chromatography-high resolution mass spectrometry (LC-HRMS) data of wastewater samples as a pre-step of a non-targeted analysis of dissolved organic matter (DOM). We provide detailed methodology on data processing and cleanup using MS processing software MZmine 2 and an own set of functions in R developed for wastewater analysis. The processing involves signal extraction, linear mass correction, reduction of noise, grouping of isotopologues, molecular formula assignment and merging of replicates. The article contains software settings and reasoning behind the choice of data extraction options. The supplementary information contains a script for the correction of signal masses using internal standards and templates of internal standard lists. We included a reproducible example as an R notebook with data cleansing workflow and data exported from MZmine. The data were used according to the described methodology in the article "A non-targeted high-resolution mass spectrometry data analysis of dissolved organic matter in wastewater treatment" by Verkh et al., 2018. Includes a linear mass correction algorithm for LC-HRMS signals. Describes a pipeline of non-targeted processing of LC-HRMS data of wastewater using free software. Provides tests and reasons for parameter choice in non-targeted LC-HRMS wastewater data extraction. (C) 2018 The Authors. Published by Elsevier B.V.
引用
收藏
页码:395 / 402
页数:8
相关论文
共 50 条
  • [21] "MS-Ready" structures for non-targeted high-resolution mass spectrometry screening studies
    McEachran, Andrew D.
    Mansouri, Kamel
    Grulke, Chris
    Schymanski, Emma L.
    Ruttkies, Christoph
    Williams, Antony J.
    JOURNAL OF CHEMINFORMATICS, 2018, 10
  • [22] A non-targeted high-resolution mass spectrometry approach for the assessment of the geographical origin of durum wheat
    Cavanna, Daniele
    Loffi, Cecilia
    Dall'Asta, Chiara
    Suman, Michele
    FOOD CHEMISTRY, 2020, 317
  • [23] Non-targeted and targeted analysis of oxylipins in combination with charge-switch derivatization by ion mobility high-resolution mass spectrometry
    Stefan Hellhake
    Sven W. Meckelmann
    Michael T. Empl
    Kristina Rentmeister
    Walter Wißdorf
    Pablo Steinberg
    Oliver J. Schmitz
    Thorsten Benter
    Nils Helge Schebb
    Analytical and Bioanalytical Chemistry, 2020, 412 : 5743 - 5757
  • [24] Non-targeted and targeted analysis of oxylipins in combination with charge-switch derivatization by ion mobility high-resolution mass spectrometry
    Hellhake, Stefan
    Meckelmann, Sven W.
    Empl, Michael T.
    Rentmeister, Kristina
    Wissdorf, Walter
    Steinberg, Pablo
    Schmitz, Oliver J.
    Benter, Thorsten
    Schebb, Nils Helge
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2020, 412 (23) : 5743 - 5757
  • [25] Non-targeted screening of pesticides for food analysis using liquid chromatography high-resolution mass spectrometry-a review
    Guo, Zeqin
    Zhu, Zhiguo
    Huang, Sheng
    Wang, Jianhua
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2020, 37 (07): : 1180 - 1201
  • [26] Parallel targeted and non-targeted quantitative analysis of steroids in human serum and peritoneal fluid by liquid chromatography high-resolution mass spectrometry
    Thomas Andrieu
    Therina du Toit
    Bruno Vogt
    Michael D. Mueller
    Michael Groessl
    Analytical and Bioanalytical Chemistry, 2022, 414 : 7461 - 7472
  • [27] Parallel targeted and non-targeted quantitative analysis of steroids in human serum and peritoneal fluid by liquid chromatography high-resolution mass spectrometry
    Andrieu, Thomas
    du Toit, Therina
    Vogt, Bruno
    Mueller, Michael D.
    Groessl, Michael
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2022, 414 (25) : 7461 - 7472
  • [28] Non-targeted analysis of electronics waste by comprehensive two-dimensional gas chromatography combined with high-resolution mass spectrometry: Using accurate mass information and mass defect analysis to explore the data
    Ubukata, Masaaki
    Jobst, Karl J.
    Reiner, Eric J.
    Reichenbach, Stephen E.
    Tao, Qingping
    Hang, Jiliang
    Wu, Zhanpin
    Dane, A. John
    Cody, Robert B.
    JOURNAL OF CHROMATOGRAPHY A, 2015, 1395 : 152 - 159
  • [29] Non-targeted analysis of tea by hydrophilic interaction liquid chromatography and high resolution mass spectrometry
    Fraser, Karl
    Harrison, Scott J.
    Lane, Geoff A.
    Otter, Don E.
    Hemar, Yacine
    Quek, Siew-Young
    Rasmussen, Susanne
    FOOD CHEMISTRY, 2012, 134 (03) : 1616 - 1623
  • [30] Non-targeted metabolomics by high resolution mass spectrometry in HPRT knockout mice
    Tschirner, Sarah K.
    Baehre, Heike
    Kaever, Alexander
    Schneider, Erich H.
    Seifert, Roland
    Kaever, Volkhard
    LIFE SCIENCES, 2016, 156 : 68 - 73