摘要
A velocity k-space formalism facilitates the analysis of flow effects for imaging sequences involving time-varying gradients such as echo-planar and spiral. For each sequence, the velocity k-space trajectory can be represented by k(v)(k(r)); that is, its velocity-frequency (k(v)) position as a function of spatial-frequency (k(r)) position. In an echo-planar sequence, k(v) is discontinuous and asymmetric. However, in a spiral sequence, k(v) is smoothly varying, circularly symmetric, and small near the k(r) origin. To compare the effects of these trajectory differences, simulated images were generated by computing the k-space values for an in-plane vessel with parabolic flow. Whereas the resulting echo-planar images demonstrate distortions and ghosting that depend on the vessel orientation, the spiral images exhibit minimal artifacts.
引用
收藏
页码:549 / 556
页数:8
相关论文
共 50 条
  • [31] Distortion correction using topup algorithm by single k-space (TASK) for echo planar imaging
    Hwang, Seon-Ha
    Lee, Hyun-Soo
    Choi, Seung Hong
    Park, Sung-Hong
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [32] Distortion correction using topup algorithm by single k-space (TASK) for echo planar imaging
    Seon-Ha Hwang
    Hyun-Soo Lee
    Seung Hong Choi
    Sung-Hong Park
    Scientific Reports, 13
  • [33] Single-shot velocity mapping by rewinding of velocity encoding with Echo-Planar Imaging
    Serial, Maria R.
    Silletta, Emilia, V
    Perlo, Josefina
    Giovacchini, Juan P.
    Velasco, Manuel, I
    Bluemich, Bernhard
    Danieli, Ernesto D.
    Casanova, Federico
    Acosta, Rodolfo H.
    JOURNAL OF MAGNETIC RESONANCE, 2019, 307
  • [34] Echo-planar Fourier velocity mapping: Simultaneous structure and flow acquisition
    Magnotta, VA
    Ehrhardt, JC
    Yuh, W
    RADIOLOGY, 1997, 205 : 1132 - 1132
  • [35] Correction of physiologically induced global off resonance effects in dynamic echo-planar and spiral functional imaging
    Pfeuffer, J
    Van de Moortele, PF
    Ugurbil, K
    Hu, XP
    Glover, GH
    MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (02) : 344 - 353
  • [36] ECHO-PLANAR IMAGING OF DIFFUSION AND PERFUSION
    TURNER, R
    LEBIHAN, D
    CHESNICK, AS
    MAGNETIC RESONANCE IN MEDICINE, 1991, 19 (02) : 247 - 253
  • [37] Referenceless interleaved echo-planar imaging
    Reeder, SB
    Atalar, E
    Faranesh, AZ
    McVeigh, ER
    MAGNETIC RESONANCE IN MEDICINE, 1999, 41 (01) : 87 - 94
  • [38] ECHO-PLANAR DIFFUSION SPECTROSCOPIC IMAGING
    BITO, Y
    HIRATA, S
    NABESHIMA, T
    YAMAMOTO, E
    MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (01) : 69 - 73
  • [39] ECHO-PLANAR MR-IMAGING
    EDELMAN, RR
    WIELOPOLSKI, P
    SCHMITT, F
    RADIOLOGY, 1994, 192 (03) : 600 - 612
  • [40] Accelerated silent echo-planar imaging
    Liebig, Patrick
    Heidemann, Robin M.
    Hensel, Bernhard
    Porter, David A.
    MAGNETIC RESONANCE IMAGING, 2019, 55 : 81 - 85