A VELOCITY K-SPACE ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR AND SPIRAL IMAGING

被引:141
|
作者
NISHIMURA, DG [1 ]
IRARRAZABAL, P [1 ]
MEYER, CH [1 ]
机构
[1] STANFORD UNIV,DEPT ELECT ENGN,STANFORD,CA 94305
关键词
FLOW IMAGING; FAST IMAGING; ANGIOGRAPHY; MAGNETIC RESONANCE IMAGING;
D O I
10.1002/mrm.1910330414
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A velocity k-space formalism facilitates the analysis of flow effects for imaging sequences involving time-varying gradients such as echo-planar and spiral. For each sequence, the velocity k-space trajectory can be represented by k(v)(k(r)); that is, its velocity-frequency (k(v)) position as a function of spatial-frequency (k(r)) position. In an echo-planar sequence, k(v) is discontinuous and asymmetric. However, in a spiral sequence, k(v) is smoothly varying, circularly symmetric, and small near the k(r) origin. To compare the effects of these trajectory differences, simulated images were generated by computing the k-space values for an in-plane vessel with parabolic flow. Whereas the resulting echo-planar images demonstrate distortions and ghosting that depend on the vessel orientation, the spiral images exhibit minimal artifacts.
引用
收藏
页码:549 / 556
页数:8
相关论文
共 50 条
  • [1] Importance of k-space trajectory on Off resonance artifact in echo-planar velocity imaging
    Jacob A Bender
    Orlando P Simonetti
    Journal of Cardiovascular Magnetic Resonance, 14 (Suppl 1)
  • [2] ANALYSIS OF FLOW EFFECTS IN ECHO-PLANAR IMAGING
    BUTTS, K
    RIEDERER, SJ
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1992, 2 (03): : 285 - 293
  • [3] ECHO-PLANAR IMAGING - IMAGE-RECONSTRUCTION FROM K-SPACE TRAJECTORIES
    MCCOLL, RM
    CLARKE, GD
    PESHOCK, RM
    RADIOLOGY, 1992, 185 : 253 - 253
  • [4] The importance of k-space trajectory on off-resonance artifact in segmented echo-planar imaging
    Bender, Jacob A.
    Ahmad, Rizwan
    Simonetti, Orlando P.
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2013, 42 (02) : 23 - 31
  • [5] Shared k-space echo planar imaging with keyhole
    Zaitsev, M
    Zilles, K
    Shah, NJ
    MAGNETIC RESONANCE IN MEDICINE, 2001, 45 (01) : 109 - 117
  • [6] 3D ''blipped'' echo-planar imaging of cortical activation with volumetric interpolation of k-space
    Mock, BJ
    Sorenson, JA
    RADIOLOGY, 1996, 201 : 704 - 704
  • [7] Partial k-space reconstruction in single-shot diffusion-weighted echo-planar imaging
    Storey, Pippa
    Frigo, Fred J.
    Hinks, R. Scott
    Mock, Bryan J.
    Collick, Bruce D.
    Baker, Nicole
    Marmurek, Jonathan
    Graham, Simon J.
    MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (03) : 614 - 619
  • [8] K-space correction of eddy-current-induced distortions in diffusion-weighted echo-planar imaging
    Papadakis, NG
    Smponias, T
    Berwick, J
    Mayhew, JEW
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (05) : 1103 - 1111
  • [9] Cardiac imaging: Comparison of two-shot echo-planar imaging with fast segmented K-space and conventional gradient-echo cine acquisitions
    Leung, DA
    Debatin, JF
    Wildermuth, S
    McKinnon, GC
    vonSchulthess, GK
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1995, 5 (06): : 684 - 688
  • [10] k-Space spatial low-pass filters can increase signal loss artifacts in echo-planar imaging
    Caparelli, E. C.