PEAK-FLOW FORECASTING WITH GENETIC ALGORITHM AND SWMM

被引:79
|
作者
LIONG, SY
CHAN, WT
SHREERAM, J
机构
[1] Dept. of Civ. Engrg., Nat. Univ. of Singapore
来源
JOURNAL OF HYDRAULIC ENGINEERING-ASCE | 1995年 / 121卷 / 08期
关键词
D O I
10.1061/(ASCE)0733-9429(1995)121:8(613)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The success of a catchment model is known to depend a great deal on the catchment-model calibration scheme applied to it. This paper presents the application of a genetic algorithm (GA) in the search for the optimal values of catchment calibration parameters. GA is linked to a widely used catchment model, the storm water management model (SWMM), and applied to a catchment in Singapore of about 6.11 km(2) in size. Six storms were considered: three for calibration and three for verification. The study shows that GA requires only a small number of catchment-model simulations and yet yields relatively high peak-flow prediction accuracy. The prediction error ranges from 0.045% to 7.265%.
引用
收藏
页码:613 / 617
页数:5
相关论文
共 50 条
  • [41] Peak-flow is related to VO2peak and exercise ventilation in children and adolescents with down syndrome
    Guerra, M
    Carbo, M
    Martinez, E
    Fernhall, B
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2004, 36 (05): : S272 - S272
  • [42] PEAK FLOW IN CHILDREN AGED 4-16 YEARS - NORMAL VALUES FOR VITALOGRAPH PEAK FLOW MONITOR, WRIGHT AND MINI WRIGHT PEAK-FLOW METERS
    WILLE, S
    SVENSSON, K
    ACTA PAEDIATRICA SCANDINAVICA, 1989, 78 (04): : 544 - 548
  • [43] Compliance with peak-now self-monitoring as measured by an electronic peak-flow monitor.
    Deshpande, AD
    Gidwani, UK
    Newman, T
    Perla, E
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A693 - A693
  • [44] HOME MONITORING BY PEAK-FLOW (PF) MEASUREMENTS OF CHILDREN WITH BRONCHIAL-ASTHMA
    AEBISCHER, CC
    KRAEMER, R
    AMERICAN REVIEW OF RESPIRATORY DISEASE, 1993, 147 (04): : A268 - A268
  • [45] DAILY VARIATIONS OF AIR-POLLUTION AND PEAK-FLOW IN 45 ASTHMATIC SUBJECTS
    MANFREDI, R
    ECHARD, Y
    LELLOUCH, J
    BULLETIN EUROPEEN DE PHYSIOPATHOLOGIE RESPIRATOIRE-CLINICAL RESPIRATORY PHYSIOLOGY, 1987, 23 : S331 - S331
  • [46] PEAK FLOW PROFILE AND EXPERT EVIDENCE - THE SIGNIFICANCE OF SELF-MEASURED PEAK-FLOW IN EXPERT EVIDENCE ON PULMONARY-FUNCTION
    WALDBURGER, R
    HOFMANN, M
    RUEGGER, M
    KNOBLAUCH, A
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1992, 122 (29) : 1070 - 1078
  • [47] PARALLEL AND DISTRIBUTED SWMM FOR INDIVIDUAL COMPUTATION IN A GENETIC ALGORITHM
    Brady, Peter David Mckellar
    Ball, James E.
    PROCEEDINGS OF THE 36TH IAHR WORLD CONGRESS: DELTAS OF THE FUTURE AND WHAT HAPPENS UPSTREAM, 2015, : 5442 - 5447
  • [48] PEAK-FLOW MEASUREMENT IN GENERAL-PRACTICE FOR CHILDREN WITH OBSTRUCTIVE LUNG-DISEASES
    BIRRER, P
    KRAEMER, R
    HELVETICA PAEDIATRICA ACTA, 1987, 42 (01) : 95 - 95
  • [49] Mini-Wright peak-flow meters are reliable after 5 yrs use
    Niggemann, B
    EUROPEAN RESPIRATORY JOURNAL, 1997, 10 (06) : 1429 - 1429
  • [50] Combination of Genetic Algorithm and Support Vector Machine for Daily Flow Forecasting
    Wang, Jianzhong
    Liu, Ling
    Chen, Juan