THE REMOVAL EFFICIENCY OF DIOXIN IN FLUE-GAS OF MSW INCINERATOR - COMPARISON OF A FABRIC FILTER WITH AN ELECTROSTATIC PRECIPITATOR

被引:5
|
作者
HIRAOKA, M [1 ]
FUJII, T [1 ]
KASHIWABARA, K [1 ]
IEYAMA, K [1 ]
KONDO, M [1 ]
机构
[1] HITACHI ZOSEN CORP,KONOHANA KU,OSAKA 554,JAPAN
关键词
D O I
10.1016/0045-6535(91)90168-D
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study was carried out at the pilot plant which was equipped a fabric filter in order to confirm the removal efficiency of Dioxin. PCDDs and PCDFs can be removed by the fabric filter. The removal efficiency of PCDDs and PCDFs was 96.9%.
引用
收藏
页码:1439 / 1444
页数:6
相关论文
共 31 条
  • [21] The Effect of Gas Temperature on Dust Resistivity and Removal Efficiency in an Extra Cold-Side Electrostatic Precipitator
    Zhang, X. H.
    Li, S. Q.
    Xiong, G. L.
    Huang, W.
    Luo, R. S.
    Guo, J.
    CLEAN COAL TECHNOLOGY AND SUSTAINABLE DEVELOPMENT, 2016, : 483 - 487
  • [22] REMOVAL OF SO2 FROM SIMULATED FLUE-GAS BY MAGNESIA SPRAY ABSORPTION - PARAMETERS AFFECTING REMOVAL EFFICIENCY AND PRODUCTS
    EGAN, BZ
    FELKER, LK
    INDUSTRIAL & ENGINEERING CHEMISTRY PROCESS DESIGN AND DEVELOPMENT, 1986, 25 (02): : 558 - 561
  • [23] Removal of PCDD/Fs from flue gas by a fixed-bed activated carbon filter in a hazardous waste incinerator
    Karademir, A
    Bakoglu, M
    Taspinar, F
    Ayberk, S
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2004, 38 (04) : 1201 - 1207
  • [24] Challenge of SO3 removal by wet electrostatic precipitator under simulated flue gas with high SO3 concentration
    Yang, Zhengda
    Zheng, Chenghang
    Zhang, Xuefeng
    Zhou, Hao
    Silva, Anthony A.
    Liu, Chungyi
    Snyder, Bob
    Wang, Yi
    Gao, Xiang
    FUEL, 2018, 217 : 597 - 604
  • [25] Experimental study on the particle removal efficiency of pellet flue gas in wire-tube electrostatic precipitators
    Cui Yongzhang
    Zhang Linhua
    Sun Jie
    Zhang Guokai
    PROCEEDINGS OF THE 2015 2ND INTERNATIONAL CONFERENCE ON MACHINERY, MATERIALS ENGINEERING, CHEMICAL ENGINEERING AND BIOTECHNOLOGY (MMECEB), 2016, 49 : 561 - 564
  • [26] PILOT-PLANT FOR NOX, SO2 AND HCL REMOVAL FROM FLUE-GAS OF MUNICIPAL WASTE INCINERATOR BY ELECTRON-BEAM IRRADIATION
    DOI, T
    OSADA, Y
    MORISHIGE, A
    TOKUNAGA, O
    MIYATA, T
    HIROTA, K
    NAKAJIMA, M
    KOMIYA, M
    MIYAJIMA, K
    BABA, S
    RADIATION PHYSICS AND CHEMISTRY, 1993, 42 (4-6): : 679 - 682
  • [27] Fabric-filter-supported catalyst for removal of harmful solid and gaseous compounds in municipal waste incinerator exhaust gas: characteristics of NOx reduction
    Kazunori Fujita
    Gouki Sasaki
    Kazuki Kobayashi
    Journal of Material Cycles and Waste Management, 1999, 1 (1): : 48 - 52
  • [28] A NOVEL ACTIVATED CARBON INJECTION METHOD TO ENHANCE PCDD/FS REMOVAL EFFICIENCY IN FLUE GAS FROM A MEDICAL WASTE INCINERATOR IN SHANGHAI, CHINA
    Qiang, N.
    He, J.
    Miao, H.
    Xie, L.
    Liu, T.
    Cao, Y.
    Li, Z.
    APPLIED ECOLOGY AND ENVIRONMENTAL RESEARCH, 2018, 16 (03): : 2717 - 2728
  • [29] FLUE-GAS CLEANING BY THE ELECTRON-BEAM-PROCESS .1. OPTIMIZATION OF REMOVAL EFFICIENCY AND ENERGY-CONSUMPTION AT THE ITS-FACILITY
    WILLIBALD, U
    PLATZER, KH
    WITTIG, S
    RADIATION PHYSICS AND CHEMISTRY, 1990, 35 (1-3): : 422 - 426
  • [30] REMOVAL EFFICIENCY OF POLYCHLORINATED DIBENZO-P-DIOXINS AND DIBENZOFURANS IN FLUE-GAS GENERATED FROM MUNICIPAL SOLID-WASTE INCINERATORS BY WATER SPRAY INTO THE GAS-FLOW
    AKIMOTO, Y
    NITO, S
    CHEMOSPHERE, 1994, 28 (08) : 1417 - 1432