MR IMAGING OF JOINTS - ANALYTIC OPTIMIZATION OF GRE TECHNIQUES AT 1.5-T

被引:36
|
作者
YAO, L
SINHA, S
SEEGER, LL
机构
关键词
D O I
10.2214/ajr.158.2.1370362
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To clarify the choice of imaging parameters for optimal gradient-recalled echo MR scanning of joints, we analyzed the behavior of contrast-to-noise and signal-to-noise ratios for spoiled (i.e., fast low-angle shot [FLASH] or spoiled GRASS) and steady-state (i.e., gradient-recalled acquisition in the steady state [GRASS] or fast imaging with steady precession) techniques at 1.5 T. The analysis is based on tissue characteristics derived from spin-echo measurements of hyaline cartilage and synovial fluid signal in the patellofemoral joints of 11 volunteers. Separate analysis of contrast-to-noise and signal-to-noise ratios for multiplanar (long TR) acquisitions shows that these parameters are each improved compared with single-slice methods. At TRs greater than 250 msec, there is no significant difference in the contrast behavior of FLASH and GRASS. For optimal contrast-to-noise ratio (synovial fluid-cartilage), the best multiplanar sequence (for TE < 23 msec) is with a short TE and a large flip angle (e.g., 400/9/73-degrees [TR/TE/flip angle]). If a single-scan or three-dimensional technique is desired, then a GRASS sequence at minimal TR and TE and intermediate flip angle (18/9/32-degrees) is best. For optimal signal-to-noise ratio (for both synovial fluid and hyaline cartilage), the best multiplanar sequence uses a short TE and an intermediate flip angle (e.g., 400/9/30-degrees). If a short TR, high signal-to-noise technique is desired, then GRASS (18/9/13-degrees) is superior to FLASH.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 50 条
  • [31] CHRONIC ACQUIRED HEPATIC-FAILURE - MR IMAGING OF THE BRAIN AT 1.5-T
    BRUNBERG, JA
    KANAL, E
    HIRSCH, W
    VANTHIEL, DH
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (05) : 909 - 914
  • [32] PITUITARY-ADENOMAS - HIGH-RESOLUTION MR IMAGING AT 1.5-T
    KUCHARCZYK, W
    DAVIS, DO
    KELLY, WM
    SZE, G
    NORMAN, D
    NEWTON, TH
    RADIOLOGY, 1986, 161 (03) : 761 - 765
  • [33] Small, patent cerebral aneurysms: Atypical appearances at 1.5-T MR imaging
    Rolen, PB
    Sze, G
    RADIOLOGY, 1998, 208 (01) : 129 - 136
  • [34] CHRONIC ACQUIRED HEPATIC-FAILURE - MR IMAGING OF THE BRAIN AT 1.5-T
    BRUNBERG, JA
    KANAL, E
    HIRSCH, W
    VANTHIEL, DH
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 157 (05) : 1111 - 1116
  • [35] Experimental nerve imaging at 1.5-T
    Nolte, Ingo
    Pham, Mirko
    Bendszus, Martin
    METHODS, 2007, 43 (01) : 21 - 28
  • [36] Uterine Cervical Carcinoma: Preoperative Staging with 3.0-T MR Imaging-Comparison with 1.5-T MR Imaging
    Hori, Masatoshi
    Kim, Tonsok
    Murakami, Takamichi
    Imaoka, Izumi
    Onishi, Hiromitsu
    Tomoda, Kaname
    Tsutsui, Tateki
    Enomoto, Takayuki
    Kimura, Tadashi
    Nakamura, Hironobu
    RADIOLOGY, 2009, 251 (01) : 96 - 104
  • [37] MR CHARACTERISTICS OF SUBDURAL HEMATOMAS AND HYGROMAS AT 1.5-T
    FOBBEN, ES
    GROSSMAN, RI
    ATLAS, SW
    HACKNEY, DB
    GOLDBERG, HI
    ZIMMERMAN, RA
    BILANIUK, LT
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (03) : 589 - 595
  • [38] MR IMAGING OF CEREBELLOPONTINE ANGLE AND INTERNAL AUDITORY-CANAL LESIONS AT 1.5-T
    PRESS, GA
    HESSELINK, JR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (02) : 241 - 251
  • [39] TUMOR RECURRENCE VERSUS FIBROSIS IN THE FEMALE PELVIS - DIFFERENTIATION WITH MR IMAGING AT 1.5-T
    EBNER, F
    KRESSEL, HY
    MINTZ, MC
    CARLSON, JA
    COHEN, EK
    SCHIEBLER, M
    GEFTER, W
    AXEL, L
    RADIOLOGY, 1988, 166 (02) : 333 - 340
  • [40] MR CHARACTERISTICS OF SUBDURAL HEMATOMAS AND HYGROMAS AT 1.5-T
    FOBBEN, ES
    GROSSMAN, RI
    ATLAS, SW
    HACKNEY, DB
    GOLDBERG, HI
    ZIMMERMAN, RA
    BILANIUK, LT
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1989, 10 (04) : 687 - 693