VARIATIONS IN BROAD-BAND SEISMIC NOISE AT IRIS/IDA STATIONS IN THE USSR WITH IMPLICATIONS FOR EVENT DETECTION

被引:0
|
作者
GIVEN, HK
机构
关键词
D O I
暂无
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Ambient noise conditions at four IRIS/IDA sites in the USSR are characterized from 0.01 to 100 Hz as part of a study to ascertain the utility of broadband three-component seismic stations in monitoring regional Eurasian seismicity. Estimates of the power spectral density of noise levels were computed for a 5-day period in two seasons (winter and summer), at two times of the day. Of these periods, lower noise conditions were found at night in the summer. In general, at 1 Hz and above, noise levels and their variations correlate predictably with the soundness of vault construction and the proximity of the station to civilization. Absolute noise levels at the IRIS/IDA/USSR sites range from a high of about -120 dB to a low of -155 dB relative to (1 m/s-2)2/Hz, between 1 and 5 Hz. A time-of-day variation in noise was observed at all sites, with noise levels during the work day ranging from 7 to 14 dB higher than night levels, depending on the site. This effect was observed only for frequencies above about 1 Hz. Observed seasonal variations (winter versus summer) are highly station dependent, although the seasonal effect is restricted to frequencies below 1 Hz and is in general centered on the microseism peak (0.1 to 0.2 Hz). Below 0.1 Hz, noise levels are influenced by the thermal and barometric isolation of the site. Low-frequency levels were not studied below 0.01 Hz. Minimum detectable magnitudes are estimated for the IRIS/IDA stations using the observed noise levels over 1 Hz. In general, a magnitude 3 event should be detectable at 1,000 km by all stations under night noise conditions of the dominant signal frequency is 1 Hz; the magnitude estimates increase with increasing frequency. These detectability estimates assume a conservative signal-to-noise ratio of 6. High-frequency data recorded by independent equipment co-located with the IRIS/IDA system during a 2-week experiment allow estimation of noise levels at the sites up to 100 Hz. Borehole versus surface noise levels recorded during the high-frequency experiment showed significant noise reduction (20 dB) can be achieved by borehole deployment at sites with exposed surface vaults. With well-isolated surface vaults, borehole noise reduction is about a factor of 2. Absolute noise levels between 1 to 10 Hz observed at IRIS/IDA/USSR sites are systematically higher than average NORESS noise by about 7 dB to 25 dB, depending on the station.
引用
收藏
页码:2072 / 2088
页数:17
相关论文
共 24 条
  • [21] RECORDING OF OCEAN-BOTTOM SEISMIC NOISE AND OF A STRONG EARTHQUAKE IN THE HIMALAYAS BY BROAD-BAND DIGITAL OBS INSTALLED ON THE MID-ATLANTIC RIDGE
    LEVCHENKO, DG
    SOLOVIEV, SL
    SONKIN, AV
    VORONINA, EV
    PHYSICS OF THE EARTH AND PLANETARY INTERIORS, 1994, 84 (1-4) : 305 - 320
  • [22] DETECTION OF BROAD-BAND PLANEWAVES IN THE PRESENCE OF GAUSSIAN-NOISE OF UNKNOWN COVARIANCE, ASYMPTOTICALLY OPTIMUM TESTS USING THE 2-D AUTOREGRESSIVE NOISE MODEL
    BAGGENSTOSS, PM
    KAY, SM
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1995, 43 (04) : 950 - 966
  • [23] THE APRIL 22, 1991, VALLE-DE-LA-ESTRELLA, COSTA-RICA (MW = 7.7) EARTHQUAKE AND ITS TECTONIC IMPLICATIONS - A BROAD-BAND SEISMIC STUDY
    GOES, SDB
    VELASCO, AA
    SCHWARTZ, SY
    LAY, T
    JOURNAL OF GEOPHYSICAL RESEARCH-SOLID EARTH, 1993, 98 (B5) : 8127 - 8142
  • [24] Detection of pre-eruptive seismic velocity variations at an andesitic volcano using ambient noise correlation on 3-component stations: Ubinas volcano, Peru, 2014
    Machacca-Puma, Roger
    Lesage, Philippe
    Larose, Eric
    Lacroix, Pascal
    Anccasi-Figueroa, Rosa M.
    JOURNAL OF VOLCANOLOGY AND GEOTHERMAL RESEARCH, 2019, 381 : 83 - 100