THEORETICAL VERSUS SRK-I AND SRK-II CALCULATION OF INTRAOCULAR-LENS POWER

被引:30
|
作者
OLSEN, T
THIM, K
CORYDON, L
机构
[1] Department of Ophthalmology, Vejle Sygehus, Vejle
来源
关键词
biometry; cataract surgery; empirical; intraocular lens power calculation; predictability; regression; theoretical;
D O I
10.1016/S0886-3350(13)80734-1
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The predictability of a theoretical, computerized (PC-assisted) intraocular lens (IOL) power calculation method and of the Sanders-Retzlaff-Kraff [SRK] I and II methods was evaluated from preoperative and postoperative biometry in 202 cataractous patients who had extracapsular cataract extraction (ECCE). The theoretical method resulted in the lowest range and standard deviation of the error, and the highest correlation coefficient between the observed and the predicted refraction (P < .05). The superiority of the theoretical approach was most clearly demonstrated when the postoperative measurements were used in the predictions (P < .001). This demonstrated the potential accuracy of the formula used and the importance of incorporating methods to predict the IOL position after surgery. If the prediction of the IOL chamber depth was properly corrected for the axial length dependence, a high prediction accuracy could be obtained in short as well as in long eyes. © 1990, American Society of Cataract and Refractive Surgery. All rights reserved.
引用
收藏
页码:217 / 225
页数:9
相关论文
共 50 条
  • [21] FACTORS AFFECTING INTRAOCULAR-LENS POWER CALCULATION
    LONGSTAFF, S
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1986, 105 : 642 - 646
  • [22] SOURCES OF ERROR IN INTRAOCULAR-LENS POWER CALCULATION
    OLSEN, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1992, 18 (02): : 125 - 129
  • [23] Hill-RBF Calculator versus Holladay2 and SRK/T Formulas for Intraocular Lens Power Selection
    Wright, Carrie
    Sudhakar, Shruti
    Andrews, Hans
    O'Rourke, Tara L.
    Scott, Ingrid U.
    Pantanelli, Seth
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [24] THEORETICAL APPROACH TO INTRAOCULAR-LENS CALCULATION USING GAUSSIAN OPTICS
    OLSEN, T
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1987, 13 (02): : 141 - 145
  • [25] Comparison of OKULIX ray-tracing software with SRK-T and Hoffer-Q formula in intraocular lens power calculation
    Ghoreyshi, Mohammad
    Khalilian, Ahmadreza
    Peyman, Mohammadreza
    Mohammadinia, Mohaddeseh
    Peyman, Alireza
    JOURNAL OF CURRENT OPHTHALMOLOGY, 2018, 30 (01): : 63 - 67
  • [26] INTRAOCULAR-LENS CALCULATION - AN EVALUATION OF BINKHORST AND SRK ESTIMATES IN 100 CONSECUTIVE CATARACT EXTRACTIONS WITH 3M TYPE-78 ANTERIOR-CHAMBER LENS IMPLANTATION
    FLEDELIUS, HC
    ALSBIRK, PH
    GOLDSCHMIDT, E
    ACTA OPHTHALMOLOGICA, 1987, 65 (05): : 579 - 584
  • [27] Influence of corneal power on intraocular lens power of the second eye in the SRK/T formula in bilateral cataract surgery
    Young Choi
    Youngsub Eom
    Jong Suk Song
    Hyo Myung Kim
    BMC Ophthalmology, 17
  • [28] Influence of corneal power on intraocular lens power of the second eye in the SRK/T formula in bilateral cataract surgery
    Choi, Young
    Eom, Youngsub
    Song, Jong Suk
    Kim, Hyo Myung
    BMC OPHTHALMOLOGY, 2017, 17
  • [29] THE COMPUTER CALCULATION OF INTRAOCULAR-LENS POWER - A CLINICAL-STUDY
    HILLMAN, JS
    TRANSACTIONS OF THE OPHTHALMOLOGICAL SOCIETIES OF THE UNITED KINGDOM, 1980, 100 (APR): : 222 - 228