Comparison of Postoperative Alignment of Total Knee Replacement Using Computer-Assisted Navigation with Conventional Guiding System in Chinese Population with Significant Coronal Femoral Bowing

被引:2
|
作者
Mai, Chow Mei Yee [1 ]
Leuk, Tsang Wai [1 ]
Kwan, Wong Man [1 ]
Bong, Lee On [1 ]
Ho, Leung Kin [1 ]
机构
[1] Pamela Youde Nethersole Eastern Hosp, Dept Orthopaed & Traumatol, Chaiwan, Hong Kong, Peoples R China
关键词
Chinese computer-assisted navigation total knee replacement; coronal femoral bowing;
D O I
10.1016/j.jotr.2014.01.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background/Purpose: Coronal femoral bowing is common in Chinese population. This might affect the restoration of mechanical alignment in conventional total knee replacement (TKR). The aim of the study was to compare the postoperative alignment of conventional TKR with computer-assisted navigation TKR (CAN-TKR), to investigate the effect of femoral bowing on postoperative alignment in conventional TKR and to understand the role of CAN-TKR in limbs with significant femoral bowing. Methods: This is a retrospective study of 331 knees that underwent TKR (either conventional or CAN-TKR) in our centre from January 2010 to June 2012. The incidence of coronal femoral bowing was measured. The postoperative alignments were compared between the two groups. Results: The incidence of excessive coronal femoral bowing was 41.4%. For patients with or without significant coronal femoral bowing, the CAN-TKR group was significantly better in restoring postoperative mechanical axis and the coronal femoral angle (p < 0.05). Proportions of outliers were also much less in the CAN-TKR group. Conclusion: CAN-TKR reduces outliers in all patients, and is especially superior in restoring mechanical alignments in patients with significant coronal femoral bowing.
引用
收藏
页码:21 / 24
页数:4
相关论文
共 42 条
  • [31] A new system of computer-assisted navigation leading to reduction in operating time in uncemented total hip replacement in a matched population
    Chaudhry F.A.
    Ismail S.Z.
    Davis E.T.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (4) : 645 - 648
  • [32] Comparison of computer-assisted navigation and conventional instrumentation for bilateral total knee arthroplasty The outcomes at mid-term follow-up
    Hsu, Robert Wen-Wei
    Hsu, Wei-Hsiu
    Shen, Wun-Jer
    Hsu, Wei-Bin
    Chang, Shr-Hsin
    MEDICINE, 2019, 98 (47)
  • [33] Comparison of postoperative alignment using fixed angle versus variable angle distal femoral resection in uncomplicated total knee replacement
    Alatishe, Kehinde Adesola
    Lawal, Wakeel Olaide
    UgbeyenAff, Michael Ebiyon
    Babalola, Ranti Oladimeji
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2023, 33 (03): : 593 - 600
  • [34] Comparison of postoperative alignment using fixed angle versus variable angle distal femoral resection in uncomplicated total knee replacement
    Kehinde Adesola Alatishe
    Wakeel Olaide Lawal
    Michael Ebiyon Ugbeye
    Ranti Oladimeji Babalola
    European Journal of Orthopaedic Surgery & Traumatology, 2023, 33 : 593 - 600
  • [35] A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery
    Henrica M. J. van der Linden-van der Zwaag
    Janneke Bos
    Huub J. L. van der Heide
    Rob G. H. H. Nelissen
    International Orthopaedics, 2011, 35 : 845 - 850
  • [36] A computed tomography based study on rotational alignment accuracy of the femoral component in total knee arthroplasty using computer-assisted orthopaedic surgery
    van der Linden-van der Zwaag, Henrica M. J.
    Bos, Janneke
    van der Heide, Huub J. L.
    Nelissen, Rob G. H. H.
    INTERNATIONAL ORTHOPAEDICS, 2011, 35 (06) : 845 - 850
  • [37] Comparison of limb and component alignment using computer-assisted navigation versus image intensifier-guided conventional total knee arthroplasty - A prospective, randomized, single-surgeon study of 467 knees
    Mullaji, Arun
    Kanna, Raj
    Marawar, Satyajit
    Kohli, Anirudh
    Sharma, Amit
    JOURNAL OF ARTHROPLASTY, 2007, 22 (07): : 953 - 959
  • [38] Distal femoral torsion positioning in total knee arthroplasty shows equal reliability using a computer-assisted system or a robotic arm
    Ferris, Marie-Camille Sabate
    Picart, Baptiste
    Boisrenoult, Philippe
    Pujol, Nicolas
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2024, 110 (02)
  • [39] Computer-assisted total knee replacement - A controlled cadaver study using a multi-parameter quantitative CT assessment of alignment (the Perth CT protocol)
    Chauhan, SK
    Clark, GW
    Lloyd, S
    Scott, RG
    Breidahl, W
    Sikorski, JM
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2004, 86B (06): : 818 - 823
  • [40] Optimization of cup positioning in THA - Comparison between conventional mechanical instrumentation and computer-assisted implanted cups by using the orthopilot navigation system