BREMSSTRAHLUNG MEASUREMENTS IN THE NEAR-INFRARED ON ASDEX

被引:13
|
作者
STEUER, KH
ROHR, H
KURZAN, B
机构
[1] Max-Planck-Institut für Plasmaphysik, EURATOM Association
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1990年 / 61卷 / 10期
关键词
D O I
10.1063/1.1141688
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In the ASDEX Thomson scattering system the scattered light of a Nd:YAG laser beam (λ=1064 nm) is measured to obtain electron density and temperature profiles every 16 ms. The same system is continuously used to measure bremsstrahlung in the near infrared, allowing determination of radial Zeff profiles. Some characteristic examples of radiation and Z eff profiles are given. The time resolution of the detection system (≤50 kHz) is sufficiently high to observe fast MHD phenomena such as sawtooth instabilities around the q=1 surface and density fluctuations in the plasma edge. Furthermore, the diagnostic can also be used for real time control of the electron density. This applies in particular in cases where large sawteeth and pellet injection generate counting errors in the interferometer signal. The relation between the line density n and the central chord bremsstrahlung signal Ub was investigated for different heating scenarios in a wide density range.
引用
收藏
页码:3084 / 3086
页数:3
相关论文
共 50 条
  • [21] In vivo measurements of water in skin by near-infrared reflectance
    Helene Curtis, Inc, Rolling Meadows, United States
    Appl Spectrosc, 7 (1001-1007):
  • [22] Transcutaneous glucose measurements using near-infrared spectroscopy
    Heise, HM
    Lampen, P
    DIABETES CARE, 2000, 23 (08) : 1208 - 1209
  • [23] Near-infrared radiance measurements as a ground reflection signature
    Gallagher III, Frank W.
    Beasley, William H.
    Applied Optics, 2002, 41 (33): : 6931 - 6936
  • [24] Advances in near-infrared measurements. Volume 1
    1600, ACS, Washington, DC, USA (116):
  • [25] Calibration strategies for near-infrared glucose measurements.
    Small, GW
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2002, 224 : U114 - U114
  • [26] Contribution of speckle noise in near-infrared spectroscopy measurements
    Ortega-Martinez, Antonio
    Zimmermann, Bernhard
    Cheng, Xiaojun
    Li, Xinge
    Yucel, Meryem Ayse
    Boas, David A.
    JOURNAL OF BIOMEDICAL OPTICS, 2019, 24 (10)
  • [27] Intercomparison of industrial near-infrared diffuse reflectance measurements
    Deadman, AJ
    Knee, PC
    ANALYTICA CHIMICA ACTA, 1999, 380 (2-3) : 401 - 411
  • [28] Effect Of Exercise In Heat On Near-infrared Spectroscopy Measurements
    Kolkhorst, Fred W.
    Hom, Clifford
    Lopez, Jon M.
    Pozos, Robert E.
    Buono, Michael J.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2005, 37 : S168 - S169
  • [29] NEAR-INFRARED
    不详
    CHEMTECH, 1992, 22 (09) : 515 - 515
  • [30] Direct removal of edge-localized pollutant emission in a near-infrared bremsstrahlung measurement
    Anderson, JK
    Andrew, PL
    Chapman, BE
    Craig, D
    Den Hartog, DJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 2107 - 2110