ALTERATIONS IN ULTRASONIC BACKSCATTER DURING EXERCISE-INDUCED MYOCARDIAL-ISCHEMIA IN HUMANS

被引:47
|
作者
VITALE, DF
BONOW, RO
GERUNDO, G
PELAGGI, N
LAURIA, G
LEOSCO, D
COLTORTI, F
BORDINI, C
RENGO, C
RENGO, F
机构
[1] NORTHWESTERN UNIV,SCH MED,DIV CARDIOL,CHICAGO,IL
[2] UNIV NAPLES FEDERICO II,FAC MED,CATTEDRA GERIATRIA,I-80131 NAPLES,ITALY
关键词
ISCHEMIA; ECHOCARDIOGRAPHY;
D O I
10.1161/01.CIR.92.6.1452
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Experimentally induced myocardial ischemia in animals causes tissue modifications that alter characteristics of the ultrasonic beam backscattered from the myocardial muscle. Alterations of backscatter parameters have been evidenced in human subjects with acute or remote myocardial infarction and during ischemia induced by angioplasty balloon occlusion or pharmacological stimuli. The effects of transient effort ischemia in humans have not been reported. The purpose of this study is to assess ultrasonic backscatter parameter changes induced by transient effort myocardial ischemia in human subjects. Methods and Results Nineteen patients with single left anterior descending coronary stenosis and 15 healthy subjects underwent ultrasonic backscatter analysis (parasternal long-axis view) at rest, immediately after a supine stress test, and 30 minutes later. Two windows were selected in each ultrasonic study: one encompassing the septum; the other, the posterior wall. Integrated backscatter was computed throughout the cardiac cycle, yielding a power curve relative to the midmyocardial region of the myocardial wall (excluding pericardial and endocardial borders). Five parameters were computed from the backscatter power curve: the maximum-minimum difference, amplitude and phase of the first harmonic Fourier fitting, phase-weighted amplitude, and time-averaged integrated backscatter difference from rest (an index of overall myocardial reflectivity). This protocol allowed comparison of the backscatter data from a region at risk of ischemia (the septum) with that from a region normally perfused (posterior wall) and a comparison with the same regions of the control group during the three ultrasonic studies. All backscatter indexes in the septum were altered significantly by exercise compared with rest values, whereas no changes were found in the normally perfused posterior wall or in the septum of the control group. All modified parameters returned to baseline values at the time of the recovery study. Conclusions These data indicate that transient, exercise-induced ischemia is associated with reduction of the cardiac cycle-dependent variation of the integrated backscatter power curve, a temporal shift in the nadir of the power curve with respect to the R wave (phase increase), and a small but detectable increase of myocardial reflectivity. These changes may be detected noninvasively in humans with ultrasonic backscatter analysis.
引用
收藏
页码:1452 / 1457
页数:6
相关论文
共 50 条
  • [31] LOCAL CONDUCTION DELAY CAUSES R WAVE AMPLITUDE INCREASE IN EXERCISE-INDUCED MYOCARDIAL-ISCHEMIA
    IKEDA, K
    KUBOTA, I
    NAKAMURA, K
    KIRIYAMA, N
    MICHIYASU, Y
    CIRCULATION, 1987, 76 (04) : 252 - 252
  • [32] ENHANCED RELEASE OF ATRIAL-NATRIURETIC-FACTOR DURING EXERCISE-INDUCED MYOCARDIAL-ISCHEMIA IN PATIENTS AFTER ACUTE MYOCARDIAL-INFARCTION
    DEMARZIO, P
    MORELLI, S
    FERRI, C
    TORREGROSSA, G
    BELLINI, C
    DEANGELIS, C
    PERRONE, A
    AGUGLIA, F
    SANTUCCI, A
    BALSANO, F
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 1992, 34 (02) : 179 - 187
  • [33] EXERCISE-INDUCED QRS PROLONGATION IN PATIENTS WITH CORONARY-ARTERY DISEASE - A MARKER OF MYOCARDIAL-ISCHEMIA
    MICHAELIDES, A
    RYAN, JM
    VANFOSSEN, D
    POZDERAC, R
    BOUDOULAS, H
    AMERICAN HEART JOURNAL, 1993, 126 (06) : 1320 - 1325
  • [34] EFFECTS OF INTRAVENOUS THEOPHYLLINE ON EXERCISE-INDUCED MYOCARDIAL-ISCHEMIA .1. IMPACT ON THE ISCHEMIC THRESHOLD
    HELLER, GV
    BARBOUR, MM
    DWEIK, RB
    CORNING, JJ
    MCCLELLAN, JR
    GARBER, CE
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (05) : 1075 - 1079
  • [35] INCREASED SENSITIVITY OF I-123 PHENYLPENTADECANOIC ACID IN THE IDENTIFICATION OF EXERCISE-INDUCED MYOCARDIAL-ISCHEMIA
    HANSEN, CL
    JANSEN, DE
    CORBETT, JR
    UGOLINI, V
    PIPPIN, JJ
    HENDERSON, EB
    KULKARNI, P
    BUJA, M
    PARKEY, RW
    WILLERSON, JT
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1987, 9 (02) : A25 - A25
  • [36] BENEFICIAL EFFECT OF ESTROGEN ON EXERCISE-INDUCED MYOCARDIAL-ISCHEMIA IN WOMEN WITH CORONARY-ARTERY DISEASE
    ROSANO, GMC
    SARREL, PM
    POOLEWILSON, PA
    COLLINS, P
    LANCET, 1993, 342 (8864): : 133 - 136
  • [37] USEFULNESS OF SEVERITY OF MYOCARDIAL-ISCHEMIA ON EXERCISE TESTING IN PREDICTING THE SEVERITY OF MYOCARDIAL-ISCHEMIA DURING DAILY ACTIVITIES
    BENHORIN, J
    MORIEL, M
    GAVISH, A
    MEDINA, A
    BANAI, S
    SHAPIRA, M
    STERN, S
    TZIVONI, D
    AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (02): : 176 - 180
  • [38] MYOCARDIAL-ISCHEMIA AT REST AND DURING EXERCISE IN UNSTABLE ANGINA
    FREEMAN, MR
    CHISHOLM, RJ
    PATT, NL
    GREYSON, ND
    KANWAR, N
    ARMSTRONG, PW
    CLINICAL RESEARCH, 1986, 34 (02): : A299 - A299
  • [39] COMPARISON OF PREVALENCE OF MANIFESTATIONS OF MYOCARDIAL-ISCHEMIA DURING EXERCISE
    BAZAZ, SA
    SUNG, BH
    SEYITHANOGLU, BY
    ZADEII, G
    WILSON, MF
    FASEB JOURNAL, 1995, 9 (03): : A47 - A47
  • [40] MYOCARDIAL STRUCTURE IN PATIENTS WITH EXERCISE-INDUCED ISCHEMIA
    HESS, OM
    SCHNEIDER, J
    NONOGI, H
    CARROLL, JD
    SCHNEIDER, K
    TURINA, M
    KRAYENBUEHL, HP
    CIRCULATION, 1988, 77 (05) : 967 - 977