AN UNSTEADY-FLOW RATE MEASUREMENT METHOD UTILIZING DYNAMIC CHARACTERISTICS BETWEEN PRESSURE AND FLOW-RATE ALONG A PIPELINE (A METHOD USING PRESSURES AT 2 SEPARATED POINTS)

被引:8
|
作者
YOKOTA, S
KIM, DT
NAKANO, K
机构
[1] Tokyo Inst of Technology, Yokohama
关键词
UNSTEADY FLOW RATE MEASUREMENT; FLUID POWER SYSTEMS; HYDRAULIC PIPELINE DYNAMICS; REAL-TIME DATA PROCESSING SYSTEM;
D O I
10.1299/jsmec1988.35.591
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper describes an approach for estimating unsteady flow rate through oil hydraulic pipelines and components in real time. In this method, unsteady flow rate is estimated by using the hydraulic pipeline dynamics and the measured pressures at two distant locations along the pipeline. Unsteady flow rate in the time domain is obtained by convolutions between the weighting functions and the measured values of pressure. The weighting functions are obtained from the transfer functions by application of the inverse fast Fourier transform (IFFT). By scheming the high-speed operations of convolutions, data processing in a microcomputer is achieved in real time, using exclusive precalculated tables. Under unsteady laminar oil flow conditions, the good agreement between the estimated and measured flow rate waveforms illustrates the validity of the method proposed here.
引用
收藏
页码:591 / 597
页数:7
相关论文
共 50 条
  • [11] WOMERSLEY METHOD APPLIED TO MEASUREMENT OF FLOW-RATE IN EXTRACORPOREAL-CIRCULATION
    LY, DP
    BOYER, P
    BARTHELEMY, R
    VIVES, M
    JOURNAL FRANCAIS DE BIOPHYSIQUE & MEDECINE NUCLEAIRE, 1978, 2 (04): : 209 - 211
  • [12] MEASUREMENT OF FLOW-RATE IN RAT PROXIMAL TUBULES WITH A NONOBSTRUCTING OPTICAL METHOD
    CHOU, CL
    MARSH, DJ
    FEDERATION PROCEEDINGS, 1987, 46 (03) : 370 - 370
  • [13] Analysis of pressure/flow-rate data with the pressure-history-recovery method
    Gilly, P
    Horne, RN
    SPE RESERVOIR EVALUATION & ENGINEERING, 1999, 2 (04) : 314 - 324
  • [14] Flow-rate Characteristics Measurement of Regulators Based on the Pressure Response in an Isothermal Tank
    Fan Wei
    Zhang Hongli
    Wang Tao
    Peng Guangzheng
    Oneyama, Naotake
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2009, 22 (05) : 633 - 638
  • [15] Flow-rate Characteristics Measurement of Regulators Based on the Pressure Response in an Isothermal Tank
    ONEYAMA Naotake
    Chinese Journal of Mechanical Engineering, 2009, 22 (05) : 633 - 638
  • [16] Development of new test method for flow-rate characteristics of pneumatic components
    Kuroshita, K
    Sekiguchi, Y
    Oshiki, K
    Oneyama, N
    POWER TRANSMISSION AND MOTION CONTROL, 2004, : 243 - 256
  • [17] Liquid flow rate measurement using the weighing method
    Balciunas, G.
    Augutis, V.
    Meskuotiene, A.
    JOURNAL OF VIBROENGINEERING, 2011, 13 (02) : 302 - 307
  • [18] STEAM FLOW-RATE TO SOLAR CAVITY REACTOR - A SIMPLE MEASUREMENT AND CONTROL METHOD
    KOGAN, A
    HODARA, I
    VANA, M
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 1991, 16 (08) : 531 - 534
  • [19] Research on Dynamic Measurement Method of Flow Rate in Tea Processing
    Zhao, Zhangfeng
    Liu, Gaohong
    Wang, Yueliang
    Peng, Jiyu
    Qiao, Xin
    Zhong, Jiang
    SENSORS, 2022, 22 (11)
  • [20] MEASUREMENT OF GAS FLOW RATE BY METHOD OF TIMING A PRESSURE DROP
    BRENNEN, W
    BROWN, RL
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1968, 39 (04): : 608 - &