ECHOCARDIOGRAPHIC DESCRIPTION OF THE CARBOMEDICS BILEAFLET PROSTHETIC HEART-VALVE

被引:80
|
作者
CHAMBERS, J
CROSS, J
DEVERALL, P
SOWTON, E
机构
[1] GUYS HOSP,DEPT CARDIOL,LONDON SE1 9RT,ENGLAND
[2] GUYS HOSP,DEPT CARDIOTHORAC SURG,LONDON SE1 9RT,ENGLAND
关键词
D O I
10.1016/0735-1097(93)90681-P
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. The aim of this study was to describe the echocardiographic appearance of the normal CarboMedics prosthesis in the aortic and mitral positions. Background. Echocardiography is the standard method of assessing prosthetic valves. However, new valve designs may still be marketed without an accompanying echocardiographic description. The CarboMedics prosthesis is in widespread use, but few noninvasive hemodynamic data have been published. Methods. Echocardiography was performed in 147 patients with a total of 96 normally functioning CarboMedics prostheses in the aortic position and 75 in the mitral position; in 24 patients, valves were implanted in both positions. The following variables were measured: peak and mean transvalvular velocities, peak and mean instantaneous gradient estimated from the modified Bernoulli equation, aortic acceleration slope, pressure half-time, transvalvular flow and effective orifice area using the continuity equation. Patterns of regurgitation were observed by transthoracic study in an valves and by transesophageal study in selected mitral valve prostheses. Results. For the aortic valve prostheses, estimated mean gradient ranged between 6 and 19 mm Hg. Effective area differed markedly among the anulus diameters (p < 0.001), with a mean value of 1 CM2 for the 19-mm valve and 2.6 cm2 for the 29-mm valve. For the mitral valve prostheses, mean gradient ranged from 3 to 7 mm Hg. There were a total of four washing leaks, one on either side of each pivotal point, and these lasted throughout systole or diastole. One jet was commonly more prominent than the other three. Conclusions. The CarboMedics prosthesis offered relatively little resistance to forward flow except at small anulus diameters. The washing jets were prominent and would be easy to misdiagnose as a sign of paraprosthetic regurgitation.
引用
收藏
页码:398 / 405
页数:8
相关论文
共 50 条
  • [31] RENAL HEMOSIDEROSIS DUE TO PROSTHETIC HEART-VALVE
    SEEDAT, YK
    MITHA, AS
    SOUTH AFRICAN MEDICAL JOURNAL, 1976, 50 (36): : 1389 - 1389
  • [32] ANTITHROMBOTIC THERAPY IN PROSTHETIC HEART-VALVE REPLACEMENT
    ISRAEL, DH
    SHARMA, SK
    FUSTER, V
    AMERICAN HEART JOURNAL, 1994, 127 (02) : 400 - 411
  • [33] PHYSICAL PRINCIPLES OF EDINBURGH PROSTHETIC HEART-VALVE
    KNIGHT, CJ
    MACLEOD, N
    TAYLOR, DEM
    MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1977, 15 (03) : 264 - 272
  • [34] RENAL HEMOSIDEROSIS DUE TO PROSTHETIC HEART-VALVE
    ROSE, AG
    SOUTH AFRICAN MEDICAL JOURNAL, 1976, 50 (23): : 873 - 873
  • [35] PROSTHETIC HEART-VALVE EXAMINATION BY DOPPLER ECHOCARDIOGRAPHY
    LABOVITZ, AJ
    WILLIAMS, GA
    NELSON, J
    HABERMEHL, K
    WINDHORST, DM
    KENNEDY, HL
    CLINICAL RESEARCH, 1985, 33 (02): : A202 - A202
  • [36] AN INVITRO STUDY OF PROSTHETIC HEART-VALVE SOUND
    THULIN, LI
    REUL, H
    GIERSIEPEN, M
    OLIN, CL
    SCANDINAVIAN JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1989, 23 (01): : 33 - 37
  • [37] CEREBRAL EMBOLI IN PROSTHETIC HEART-VALVE PATIENTS
    BRAEKKEN, SK
    RUSSELL, D
    BRUCHER, R
    SVENNEVIG, J
    STROKE, 1994, 25 (03) : 739 - 739
  • [38] CEREBRAL EMBOLI IN PROSTHETIC HEART-VALVE PATIENTS
    BRAEKKEN, SK
    RUSSELL, D
    BRUCHER, R
    SVENNEVIG, J
    STROKE, 1994, 25 (01) : 260 - 260
  • [39] COMPLICATIONS AFTER PROSTHETIC HEART-VALVE REPLACEMENT
    LUCK, J
    SCHWEPPER, D
    BOTH, A
    HAERTEN, K
    HERZER, K
    LOOGEN, F
    ZEITSCHRIFT FUR KARDIOLOGIE, 1977, 66 (08): : 436 - 442
  • [40] FIBRINOLYTIC THERAPY FOR PROSTHETIC HEART-VALVE THROMBOSIS
    RABAGO, R
    CORRALES, M
    REY, M
    TUNON, J
    CRIADO, A
    ZARAGOZA, R
    RABAGO, P
    CIRCULATION, 1993, 88 (04) : 342 - 342