STUDY ON COMPARISON BETWEEN LANDMARK GUIDED (BRINKMAN'S TECHNIQUE) AND ULTRASOUND GUIDED INTERNAL JUGULAR VEIN CANNULATION

被引:0
|
作者
Vinod, K. [1 ]
Walling, Sashi T. [2 ]
机构
[1] Shri Sathya Sai Med Coll & Res Inst, Dept Anaesthesiol, Ammapettai, Tamil Nadu, India
[2] Shri Sathya Sai Med Coll & Res Inst, Dept Gen Surg, Ammapettai, Tamil Nadu, India
关键词
Brinkman's technigue; Landmark guided technique; Ultrasound guided technique; Internal Jugular Vein;
D O I
10.14260/jemds/2015/1287
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Technique of cannulating the central veins, until recently has been based on landmark guided technique. Recently ultrasound machines with high frequency probes are being used to increase success rate and reducing complications. OBJECTIVE: In our study we compare landmark guided technique (Brinkman's technique)((1)) with ultrasound guided technique. STUDY DESIGN: outcome was evaluated in terms of 1) Number of attempts 2) Access time 3) mechanical complications 4) success rate. RESULTS: Access time was reduced and high success rate was recorded in ultrasound guided group and the complication rate was considerably low in the same group. Hence ultrasound guided cannulation is comparatively superior to landmark guided cannulation.
引用
收藏
页码:8894 / 8899
页数:6
相关论文
共 50 条
  • [31] Ultrasound-guided internal jugular vein cannulation: Can an artery be missed?
    Singh, Gyaninder Pal
    Chauhan, Vikas
    Kapoor, Indu
    Kumar, Abhyuday
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2018, 34 (01) : 130 - 131
  • [32] Neonatologist-Performed Ultrasound-Guided Internal Jugular Vein Cannulation
    Thakur, Anup
    Modi, Manoj
    Kler, Neelam
    Garg, Pankaj
    INDIAN PEDIATRICS, 2023, 60 (01) : 72 - 74
  • [33] Seeing Is Believing: Ultrasound-Guided Internal Jugular Vein Cannulation Response
    Lamperti, Massimo
    Subert, Matteo
    Cortellazzi, Paolo
    Vailati, Davide
    Caldiroli, Dario
    ANESTHESIA AND ANALGESIA, 2012, 115 (06): : 1471 - 1471
  • [34] Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery
    WANG Yao
    WANG Gang
    GAO Chang-qing
    中华医学杂志(英文版), 2013, 126 (13) : 2414 - 2417
  • [35] Needle and guidewire visualization in ultrasound-guided internal jugular vein cannulation
    Moak, James H.
    Lyons, Michael S.
    Wright, Stewart W.
    Lindsell, Christopher J.
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2011, 29 (04): : 432 - 436
  • [36] Neonatologist-Performed Ultrasound-Guided Internal Jugular Vein Cannulation
    Anup Thakur
    Manoj Modi
    Neelam Kler
    Pankaj Garg
    Indian Pediatrics, 2023, 60 : 72 - 74
  • [37] Absence of the Right Internal Jugular Vein During Ultrasound-Guided Cannulation
    Alagoz, Ali
    Tunc, Mehtap
    Sazak, Hilal
    Pehlivanoglu, Polat
    Gokcek, Atila
    Ulus, Fatma
    TURKISH JOURNAL OF ANAESTHESIOLOGY AND REANIMATION, 2015, 43 (03) : 212 - 214
  • [38] Ultrasound-guided cannulation of the internal jugular vein in robotic cardiac surgery
    Wang Yao
    Wang Gang
    Gao Chang-qing
    CHINESE MEDICAL JOURNAL, 2013, 126 (13) : 2414 - 2417
  • [39] INTERNAL JUGULAR-VEIN CANNULATION GUIDED BY ECHOCARDIOGRAPHY
    TROIANOS, CA
    SAVINO, JS
    ANESTHESIOLOGY, 1991, 74 (04) : 787 - 789
  • [40] Comparison between long- and short-axis techniques for ultrasound-guided cannulation of internal jugular vein
    Shrestha, Gentle Sunder
    Gurung, Arjun
    Koirala, Sabin