MASS-TRANSFER EFFICIENCY OF A LARGE-SCALE SIEVE TRAY EXTRACTOR

被引:5
|
作者
SEIBERT, AF
FAIR, JR
机构
[1] Separations Research Program, The University of Texas at Austin, Austin
关键词
D O I
10.1021/ie00022a003
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The mass transfer efficiency and phase flow capacity of a 42.5-cm-diameter (i.d.) sieve tray extractor has been investigated. The extraction of acetone from water with toluene was chosen because of the large amount of data for comparison with the performance of other devices, and particularly because of available data for a smaller sieve tray extractor tested in the same laboratory. For capacity studies, the Isopar-m/water system was also used. The performance of the sieve trays was compared with that of sprays and packings in the same column. Important parameters were found to be phase flow rates, flow ratios, and column diameter. Mechanistic hydraulic and mass transfer models, found to correlate well the experimental data, are presented in the paper.
引用
收藏
页码:2213 / 2219
页数:7
相关论文
共 50 条
  • [21] Hydrodynamics and mass transfer in heterogeneous distillation with sieve tray column
    Mortaheb, HR
    Kosuge, H
    Asano, K
    CHEMICAL ENGINEERING JOURNAL, 2002, 88 (1-3) : 59 - 69
  • [22] MASS-TRANSFER AT LIQUID SIDE ON PERFORM CONTACT TRAY
    SUNDERMANN, U
    KULBE, B
    CHEMISCHE TECHNIK, 1974, 26 (09): : 558 - 560
  • [23] MASS-TRANSFER AND PHASE-SEPARATION IN CENTRIFUGAL EXTRACTOR
    BARZ, H
    EICHLER, R
    CHEMISCHE TECHNIK, 1980, 32 (07): : 380 - 380
  • [24] ANALYSIS OF EXTRACTOR PERFORMANCE .4. MASS-TRANSFER
    MISEK, T
    HAMAN, J
    STANGL, D
    CHEMICAL ENGINEERING JOURNAL AND THE BIOCHEMICAL ENGINEERING JOURNAL, 1988, 39 (02): : 79 - 86
  • [25] Mass-transfer of two fluids in fiber film extractor
    Li, Ruxin
    Zhang, Haiguang
    Fan, Yiping
    You, Mingyang
    Lu, Chunxi
    Huagong Xuebao/CIESC Journal, 2010, 61 (09): : 2328 - 2333
  • [26] MASS-TRANSFER IN THE LIQUID-PHASE ON AN ELASTIC SIEVE PLATE OF LARGE OPEN AREA
    BESPALOV, AV
    KULESHOV, OG
    JOURNAL OF APPLIED CHEMISTRY OF THE USSR, 1986, 59 (01): : 194 - 196
  • [27] MASS-TRANSFER OF HIGHLY VISCOUS MEDIA ON SIEVE TRAYS
    MAHIOUT, S
    VOGELPOHL, A
    FETT WISSENSCHAFT TECHNOLOGIE-FAT SCIENCE TECHNOLOGY, 1987, 89 (11): : 431 - 431
  • [28] Axial mixing in a large-scale packed extractor
    Becker, O
    Seibert, A
    CHEMIE INGENIEUR TECHNIK, 2000, 72 (04) : 359 - 364
  • [29] Mass transfer in foam and froth regimes in distillation with sieve tray column
    Mortaheb, HR
    Kosuge, H
    Asano, K
    JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 2001, 34 (04) : 493 - 500
  • [30] A large-scale laboratory extractor of the soxhlet type
    Rapp, KE
    Woodmansee, CW
    McHargue, JS
    INDUSTRIAL AND ENGINEERING CHEMISTRY-ANALYTICAL EDITION, 1943, 15 : 351 - 351