SPATIAL-RESOLUTION OF FODRIN PROTEOLYSIS IN POSTISCHEMIC BRAIN

被引:0
|
作者
SAIDO, TC
YOKOTA, M
NAGAO, S
YAMAURA, I
TANI, E
TSUCHIYA, T
SUZUKI, K
KAWASHIMA, S
机构
[1] HYOGO MED UNIV,DEPT NEUROSURG,NISHINOMIYA,HYOGO 663,JAPAN
[2] SOPHIA UNIV,DEPT CHEM,CHIYODA KU,TOKYO 102,JAPAN
[3] UNIV TOKYO,INST MOLEC & CELLULAR BIOSCI,BUNKYO KU,TOKYO 113,JAPAN
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
One of the major obstacles in investigating in vivo proteolytic phenomena has been the inaccessibility to spatial information as to where in the tissue the reaction proceeds because the orthodox method employing electrophoretic analysis requires homogenization of samples and thus results in loss of such spatial information. To overcome this technical drawback, we have developed methodology to produce antibodies that specifically distinguish a proteolyzed form of a given protein from its intact form. Here we describe our immunohistochemical observation of calpain-catalyzed fodrin proteolysis in postischemic gerbil hippocampus, using an antibody exclusively specific to the proteolyzed 150-kDa form of fodrin alpha subunit. Our data establish a novel discovery that transient (10 min) global forebrain ischemia followed by reperfusion induces at least two distinct phases of fodrin proteolysis in hippocampus: an early phase in molecular layer and in stratum oriens of CA3 and CA1 sectors within 15 min and a late drastic and persistent phase in the entire CA1 after 4-24 h. The former may be one of the early events initiating the complex cascade leading to the delayed neuronal death, while the latter should be considered as a more direct cause for the actual degeneration in CA1.
引用
收藏
页码:25239 / 25243
页数:5
相关论文
共 50 条
  • [21] HIGH SPATIAL-RESOLUTION OF PANCAKES
    BUCHERT, T
    ASTROPHYSICS AND SPACE SCIENCE, 1990, 171 (1-2) : 135 - 139
  • [22] SPATIAL-RESOLUTION OF THE PRESSURE ANEMOMETER
    OOST, WA
    KOMEN, GJ
    JOURNAL OF CLIMATE AND APPLIED METEOROLOGY, 1983, 22 (12): : 2085 - 2094
  • [23] SPATIAL-RESOLUTION IN INDUSTRIAL TOMOGRAPHY
    CHIANG, BS
    GAUTAM, SR
    HOPKINS, FF
    MORGAN, IL
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1983, 30 (02) : 1671 - 1676
  • [24] SPATIAL-RESOLUTION - NO HIGH THRESHOLD
    BENZSCHAWEL, TL
    COHN, TE
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1980, 70 (12) : 1585 - 1585
  • [25] Conceptual Design of High Spatial-Resolution SPECT System for Human Brain
    Zeniya, Tsutomu
    Hirano, Yoshiyuki
    Tominaga, Takanori
    Hori, Yuki
    Watabe, Hiroshi
    Sakimoto, Tomonori
    Sohlberg, Antti
    Minato, Kotaro
    Hatazawa, Jun
    Iida, Hidehiro
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3426 - 3428
  • [27] ON THE SPATIAL-RESOLUTION OF EDX COMPOSITION DETERMINATION
    IMESON, D
    ULTRAMICROSCOPY, 1982, 9 (03) : 307 - 310
  • [28] Spatial-resolution enhancement in computed tomography
    Pan, XC
    Yu, LF
    Kao, CM
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (02) : 246 - 253
  • [29] A NOTE ON THE SPATIAL-RESOLUTION OF CATHODOLUMINESCENCE IMAGES
    DONOLATO, C
    PHYSICA STATUS SOLIDI A-APPLIED RESEARCH, 1994, 141 (02): : K131 - K132
  • [30] OPTIMIZATION OF SPATIAL-RESOLUTION IN SPRITE DETECTORS
    ASHLEY, T
    ELLIOTT, CT
    WHITE, AM
    WOTHERSPOON, JTM
    JOHNS, MD
    INFRARED PHYSICS, 1984, 24 (01): : 25 - 33