ONLINE ASSESSMENT OF VENTRICULAR-FUNCTION BY AUTOMATIC BOUNDARY DETECTION AND ULTRASONIC BACKSCATTER IMAGING

被引:222
|
作者
PEREZ, JE [1 ]
WAGGONER, AD [1 ]
BARZILAI, B [1 ]
MELTON, HE [1 ]
MILLER, JG [1 ]
SOBEL, BE [1 ]
机构
[1] WASHINGTON UNIV,SCH MED,DEPT PHYS,ST LOUIS,MO 63110
关键词
D O I
10.1016/0735-1097(92)90484-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To provide an approach suitable for on-line analysis of ventricular function, a conventional two-dimensional ultrasound imaging system was modified to detect and track blood-tissue interfaces in real time based on their quantitative acoustic properties. This modification permitted on-line display of the left ventricular cavity area, fractional area change, volumes and ejection fraction on a beat by beat basis. Images were obtained from 54 patients and 12 normal subjects with broad ranges of ventricular dimensions and systolic function. On-line measurements of cavity areas were compared with off-line measurements of cavity areas (analysis of videotaped conventional images). Left ventricular cavity areas measured on-line from short-axis views correlated closely with off-line views as did areas from apical views. On-line fractional area change correlated well with ejection fraction calculated off-line. More than 70% of patients could be studied adequately with the approach developed. Thus, automatic boundary detection based on quantitative assessment of tissue acoustic properties permits on-line quantitation of ventricular cavity areas and indexes of function.
引用
收藏
页码:313 / 320
页数:8
相关论文
共 50 条
  • [31] POSTOPERATIVE MEASUREMENTS OF VENTRICULAR-FUNCTION IN MAN USING AN IMPLANTABLE ULTRASONIC SENSOR
    HARTLEY, CJ
    RABINOVITZ, RS
    LEE, HS
    CHELLY, JE
    NOON, GP
    BOLLI, R
    CATHETER-BASED SENSING AND IMAGING TECHNOLOGY, 1989, 1068 : 53 - 58
  • [32] DO THE EPICARDIAL ELECTRODES OF AN IMPLANTED AUTOMATIC DEFIBRILLATOR IMPAIR VENTRICULAR-FUNCTION
    TRAPPE, HJ
    DANIEL, WG
    KLEIN, H
    FRANK, G
    WENZLAFF, P
    LICHTLEN, PR
    ZEITSCHRIFT FUR KARDIOLOGIE, 1986, 75 : 77 - 77
  • [33] EFFECTS OF VENTRICULAR-FUNCTION ON SURVIVAL IN PATIENTS WITH AUTOMATIC IMPLANTABLE CARDIOVERTER DEFIBRILLATOR
    SINGER, I
    SLATER, D
    STAVENS, C
    KUPERSMITH, J
    CLINICAL RESEARCH, 1990, 38 (03): : A885 - A885
  • [34] ASSESSMENT OF VENTRICULAR-FUNCTION IN INFANTS AND CHILDREN RESPONSE TO DOBUTAMINE INFUSION
    HURWITZ, RA
    SIDDIQUI, A
    CALDWELL, RL
    WEETMAN, RM
    GIROD, DA
    CLINICAL NUCLEAR MEDICINE, 1990, 15 (08) : 556 - 559
  • [35] ASSESSMENT OF VENTRICULAR-FUNCTION FROM ANGIOGRAM - QUALITATIVE AND QUANTITATIVE METHODS
    KOBER, G
    BUSSMANN, WD
    HOPF, R
    THALER, R
    KALTENBACH, M
    HERZ KREISLAUF, 1976, 8 (04): : 180 - 187
  • [36] ASSESSMENT OF VENTRICULAR-FUNCTION BY RADIONUCLIDE VENTRICULOGRAPHY IN MYOCARDIAL-INFARCTION
    SCHMIDT, A
    KOHLER, J
    HENZE, E
    WIESHAMMER, S
    SEIBOLD, H
    STAUCH, M
    HERZ KREISLAUF, 1987, 19 (11): : 538 - 543
  • [37] ASSESSMENT OF RIGHT VENTRICULAR-FUNCTION IN CHILDREN WITH CYSTIC-FIBROSIS
    GIBBESON, MA
    MORTON, JR
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1982, 12 (02): : 216 - 217
  • [38] PREOPERATIVE ASSESSMENT OF MYOCARDIAL VIABILITY BY REST-THALLIUM-201 IMAGING IN PATIENTS WITH REDUCED VENTRICULAR-FUNCTION
    RAGOSTA, M
    GIMPLE, LW
    KRON, IL
    BELLER, GA
    CIRCULATION, 1990, 82 (04) : 294 - 294
  • [39] ASSESSMENT OF VENTRICULAR-FUNCTION WITH 1ST-PASS ANGIOCARDIOGRAPHY
    SCHAD, N
    NICKEL, O
    CARDIOVASCULAR RADIOLOGY, 1979, 2 (03): : 149 - 160
  • [40] ECHOCARDIOGRAPHIC ASSESSMENT OF VENTRICULAR-FUNCTION DURING EXERCISE IN HYPERTENSIVE CHILDREN
    BOERTH, RC
    BREITWESER, JA
    PETTY, D
    WEINBERGER, JT
    DEVLIN, JL
    PEDIATRIC RESEARCH, 1981, 15 (04) : 459 - 459