AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON AN ELECTROCATALYTICALLY BULK-MODIFIED EPOXY-GRAPHITE BIOCOMPOSITE

被引:39
|
作者
CESPEDES, F [1 ]
MARTINEZFABREGAS, E [1 ]
ALEGRET, S [1 ]
机构
[1] UNIV AUTONOMA BARCELONA,DEPT QUIM,SENSORS & BIOSENSORS GRP,E-08193 BARCELONA,SPAIN
关键词
AMPEROMETRY; BIOSENSORS; CATALYTIC METHODS; BIOCOMPOSITES; GLUCOSE BIOSENSOR; EPOXY-GRAPHITE BIOCOMPOSITE;
D O I
10.1016/0003-2670(93)80003-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An inexpensive, robust, polishable and easily machinable amperometric glucose transducer was constructed. The biocomposite materials used were graphite, palladium-gold, non-conducting epoxy resin and glucose oxidase. The enzyme retains its bioactivity in the rigid epoxy-graphite matrix. The electrocatalytic oxidation of hydrogen peroxide is enhanced by gold-palladium and it is used as the analytical signal (at 900 mV vs. Ag/AgCl in a pH 7.00 buffered solution with 0.1 M phosphate and 0.1 M KCI). The biosensor exhibits a linear response to glucose in the 0.01-2 mM range and produces steady-state signals within a few seconds (6 s for 95% signal). Simple polishing procedures can be used to generate a fresh bioactive transducer surface.
引用
收藏
页码:21 / 26
页数:6
相关论文
共 50 条
  • [1] FERMENTATION MONITORING USING A GLUCOSE BIOSENSOR BASED ON AN ELECTROCATALYTICALLY BULK-MODIFIED EPOXY-GRAPHITE BIOCOMPOSITE INTEGRATED IN A FLOW SYSTEM
    CESPEDES, F
    VALERO, F
    MARTINEZFABREGAS, E
    BARTROLI, J
    ALEGRET, S
    ANALYST, 1995, 120 (08) : 2255 - 2258
  • [2] AMPEROMETRIC GLUCOSE BIOSENSOR BASED ON A TETRATHIAFULVALENE-MEDIATED EPOXY-GRAPHITE BIOCOMPOSITE
    CESPEDES, F
    MARTINEZFABREGAS, E
    ALEGRET, S
    ELECTROANALYSIS, 1994, 6 (09) : 759 - 763
  • [3] Amperometric biosensors based on bulk-modified epoxy graphite biocomposites
    Alegret, S
    Alonso, J
    Bartroli, J
    Cespedes, F
    MartinezFabregas, E
    delValle, M
    SENSORS AND MATERIALS, 1996, 8 (03) : 147 - 153
  • [4] AMPEROMETRIC BIOSENSOR FOR PHENOLS BASED ON A TYROSINASE GRAPHITE-EPOXY BIOCOMPOSITE
    WANG, J
    FANG, L
    LOPEZ, D
    ANALYST, 1994, 119 (03) : 455 - 458
  • [5] Hydrogen peroxide amperometric biosensor based on a peroxidase-graphite-epoxy biocomposite
    Morales, A
    Cespedes, F
    Munoz, J
    MartinezFabrega, E
    Alegret, S
    ANALYTICA CHIMICA ACTA, 1996, 332 (2-3) : 131 - 138
  • [6] AMPEROMETRIC DETERMINATION OF PESTICIDES USING A BIOSENSOR BASED ON A POLISHABLE GRAPHITE-EPOXY BIOCOMPOSITE
    MARTORELL, D
    CESPEDES, F
    MARTINEZFABREGAS, E
    ALEGRET, S
    ANALYTICA CHIMICA ACTA, 1994, 290 (03) : 343 - 348
  • [7] Amperometric Determination of Glucose with FeO and Glucose Oxidase Bulk-Modified Screen-Printed Carbon Ink Biosensor
    Turkusic, E.
    Begic, S.
    Kahrovic, E.
    Kalcher, K.
    HEALTHMED, 2011, 5 (05): : 1117 - 1122
  • [8] Amperometric determination of glucose with an MnO2 and glucose oxidase bulk-modified screen-printed carbon ink biosensor
    Turkusic, E
    Kalcher, K
    Schachl, K
    Komersova, A
    Bartos, M
    Moderegger, H
    Svancara, I
    Vytras, K
    ANALYTICAL LETTERS, 2001, 34 (15) : 2633 - 2647
  • [9] Glucose biosensor based on a reagentless graphite-epoxy screen-printable biocomposite
    Galan-Vidal, CA
    Munoz, J
    Dominguez, C
    Alegret, S
    SENSORS AND ACTUATORS B-CHEMICAL, 1997, 45 (01) : 55 - 62
  • [10] A new amperometric biosensor for fructose determination based on epoxy-graphite-TTF-TCNQ-FDH-biocomposite
    Montanez-Soto, Jose Luis
    Alegret, Salvador
    Salazar-Montoya, Juan Alfredo
    Ramos-Ramirez, Emma Gloria
    EUROPEAN FOOD RESEARCH AND TECHNOLOGY, 2006, 223 (03) : 379 - 386