PARTICLE CONTAMINATION BELOW A ROBOT ARM IN A CLEANROOM

被引:0
|
作者
KUEHN, TH
WU, Y
LIU, BYH
机构
来源
JOURNAL OF THE IES | 1993年 / 36卷 / 05期
关键词
PARTICLE; DISPERSION TRANSPORT; CYLINDER; INJECTION; PROFILE; LOGNORMAL; CORRELATION;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Experimental velocity and particle concentration data have been obtained near a circular cylinder robot arm in a chamber that simulates a vertical unidirectional flow Class 10 cleanroom. The airflow field around the robot arm has been characterized using a hot wire anemometer. Both mean velocities and turbulence spectral data were obtained. Sodium chloride particles were injected through small holes below the arm to simulate particles generated by moving joints. Results indicate that the turbulent wake near the arm causes an unsymmetrical widespread dispersion of the particles from a single point source on the arm. Particles disperse much stronger along the cylinder axis than normal to the cylinder near the injection point.
引用
收藏
页码:43 / 50
页数:8
相关论文
共 50 条
  • [11] Airborne molecular contamination: Cleanroom control strategies
    Higley, JK
    Joffe, MA
    SOLID STATE TECHNOLOGY, 1996, 39 (07) : 211 - &
  • [12] Cleanroom mats: an investigation of particle removal
    Univ of Glasgow, Glasgow, United Kingdom
    J Inst Envir Sci, 4 (19-27):
  • [13] Cleanroom technologies - Using contamination and ESD tests to qualify and certify cleanroom gloves - Part 1
    Welker, RW
    Lehman, PG
    MICRO, 1999, 17 (05): : 47 - 51
  • [14] Cleanroom mats: An investigation of particle removal
    Whyte, W
    Shields, T
    Prvan, T
    JOURNAL OF THE INSTITUTE OF ENVIRONMENTAL SCIENCES, 1996, 39 (04): : 19 - 27
  • [15] Evaluating cleanroom supplies for contamination-free manufacturing
    Wang, RP
    Wu, S
    Williams, B
    Dyer, T
    Ramani, N
    MICRO, 1996, 14 (02): : 39 - 47
  • [16] CHARACTERIZATION OF CLEANROOM WIPERS - PARTICLE GENERATION
    KWOK, WK
    SUMMERS, JT
    JOURNAL OF THE IES, 1990, 33 (06): : 33 - 39
  • [17] PARTICLE CONTAMINATION OF HIGH-VOLTAGE DC INSULATORS BELOW CORONA THRESHOLD
    HORENSTEIN, MN
    MELCHER, JR
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1979, 14 (06): : 297 - 305
  • [18] Improvement of Airflow Distribution and Contamination Control for a Biotech Cleanroom
    Wang, Fujen
    Permana, Indra
    Lee, Kwowhei
    Rakshit, Dibakar
    Rosulindo, Parisya Premiera
    ATMOSPHERE, 2022, 13 (02)
  • [19] PERFORMANCE IMPROVEMENT OF THE AIRFLOW DISTRIBUTION AND CONTAMINATION CONTROL IN A CLEANROOM
    Wang, Fu-Jen
    Wong, King-Leung
    Lai, Chi-Ming
    Sun, Chen-Yi
    Luo, Yuan-Hong
    FIFTH INTERNATIONAL WORKSHOP ON ENERGY AND ENVIRONMENT OF RESIDENTIAL BUILDINGS AND THIRD INTERNATIONAL CONFERENCE ON BUILT ENVIRONMENT AND PUBLIC HEALTH, VOL I AND II, PROCEEDINGS, 2009, : 376 - 384
  • [20] Contamination impact of Station Brush Fire on cleanroom facilities
    Carey, Phil
    Blakkolb, Brian
    OPTICAL SYSTEM CONTAMINATION: EFFECTS, MEASUREMENTS, AND CONTROL 2010, 2010, 7794