ACCURACY OF 4 OXIMETRY DEVICES FOR CONTINUOUS MONITORING OR MIXED-VENOUS OXYGEN-SATURATION DURING ABDOMINAL AORTIC-SURGERY

被引:0
|
作者
ZAUNE, U
SPIES, C
PAULI, MHF
BOEDEN, G
MARTIN, E
机构
[1] KLINIKUM NURNBERG,ANASTHESIOL & OPERAT INTENS MED,FLURSTR 17,W-8500 NURNBERG 90,GERMANY
[2] UNIV HEIDELBERG,ANAESTHESIOL KLIN,W-6900 HEIDELBERG,GERMANY
来源
ANAESTHESIST | 1992年 / 41卷 / 02期
关键词
D O I
暂无
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Several systems for mixed-venous oximetry are now available. There are one three-wave-length system (Abbott) and three two-wave-length systems with (Spectramed) and without automatic correction for hemoglobin or hematocrit (Edwards). The purpose of this prospective randomized study was to compare the different systems and to examine the accuracy of continuous mixed-venous oximetry during abdominal aortic surgery. Eighty patients had a radial artery cannula and one of the following fiberoptic pulmonary artery catheters inserted before induction of anesthesia: Swan-GanZ(TM) oximetry TD catheter (Edwards), Swan-GanZ(TM) flow-directed oximetry thermodilution paceport catheter (Baxter, Edwards Division), SpectraCath STP(TM) (Spectramed), and Opticath(TM) (Abbott), Mixed-venous O2 saturation was monitored by oximetry computers: SAT-1 (Edwards), SAT-2 (Baxter, Edwards Division), Hemopro2 (Spectramed), and Oximetrix 3 (Abbott). As a method of reference, mixed-venous blood samples were drawn and immediately analyzed by an OSM3-Hemoximeter. Data sets were obtained at eight predetermined times. Hemoglobin was kept constant at +/- 1 g.dl-1. Continuous oximetry in comparison to in-vitro measurements yielded a correlation coefficient of r = 0.873 (P less-than-or-equal-to 0.0001) and a value of bias and precision (b +/- p) of -0.9 +/- 2.6% for the SAT-1, r = 0.815 (P less-than-or-equal-to 0.0001) and b +/- p = -2.2 +/- 2.5% for the SAT-2, r = 0.901 (P less-than-or-equal-to 0.0001) and b +/- p = 0.35 +/- 2.5% for the Hemopro2, and r = 0.920 (P less-than-or-equal-to 0. 0001) and b +/- p = 0.1 +/- 1.8% for the Oximetrix 3, respectively. Significant differences between the catheters were found concerning r (P less-than-or-equal-to 0.01) and bias (P less-than-or-equal-to 0.05): the accuracy of the Oximetrix 3 was superior to both SATs and that of the Hemopro2 was superior to the SAT-2. Precision was best in the Oximetrix 3, but was not significantly different between the groups. Our findings demonstrate that mixed-venous oximetry is a reliable on-line method of measuring SvBARO2. Our data suggest that the Oximetrix 3 and Hemopro2 are more accurate than the SAT-2, possibly because the Oximetrix 3 is a three-wave-length system and the Hemopro2 is a two-wave-length but three-optical-fiber system in comparison to the SAT, which is a two-wave-length, two-optical-fiber system. Since bias and not precision was significantly different between the groups, it might also be that another algorithm in both SATs, especially the SAT-2, could correct the differences in the presence of stable hemoglobin levels.
引用
收藏
页码:71 / 75
页数:5
相关论文
共 50 条
  • [21] THE CONTINUOUS MEASUREMENT OF MIXED VENOUS OXYGEN-SATURATION
    HARPIN, RP
    DOWNER, JP
    CHEST, 1985, 87 (06) : 845 - 845
  • [22] THE PHYSIOLOGICAL-BASIS FOR CONTINUOUS MIXED VENOUS OXYGEN-SATURATION MONITORING
    WHITE, KM
    WINSLOW, EH
    CLARK, AP
    TYLER, DO
    HEART & LUNG, 1990, 19 (05): : 548 - 551
  • [23] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION AS AN INDICATOR OF PHARMACOLOGIC INTERVENTION
    HASSAN, E
    GREEN, JA
    NARA, AR
    JARVIS, RC
    KASMER, RJ
    POSPISIL, R
    CHEST, 1989, 95 (02) : 406 - 409
  • [24] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    BAELE, PL
    MCMICHAN, JC
    MARSH, HM
    SILL, JC
    SOUTHORN, PA
    ANESTHESIA AND ANALGESIA, 1982, 61 (06): : 513 - 517
  • [25] CONTINUOUS MONITORING OF MIXED VENOUS-BLOOD OXYGEN-SATURATION - REPLY
    BOUTROS, A
    CRITICAL CARE MEDICINE, 1987, 15 (01) : 87 - 87
  • [26] POSTOPERATIVE MIXED VENOUS OXYGEN-SATURATION MONITORING
    BARON, JF
    BENSOUDA, A
    CORIAT, P
    ACP-APPLIED CARDIOPULMONARY PATHOPHYSIOLOGY, 1988, 2 (04): : 327 - 332
  • [27] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN HEMODYNAMICALLY UNSTABLE PATIENTS
    BIRMAN, H
    HAQ, A
    HEW, E
    ABERMAN, A
    CHEST, 1984, 86 (05) : 753 - 756
  • [28] CONTINUOUS MONITORING OF MIXED VENOUS OXYGEN-SATURATION IN SEPTIC SHOCK - REPLY
    HEISELMAN, D
    JONES, J
    CANNON, L
    JOURNAL OF CLINICAL MONITORING, 1987, 3 (03): : 214 - 214
  • [29] ONLINE MONITORING OF MIXED VENOUS OXYGEN-SATURATION AFTER CARDIOTHORACIC SURGERY
    KRAUSS, XH
    VERDOUW, PD
    HUGENHOLTZ, PG
    NAUTA, J
    THORAX, 1975, 30 (06) : 636 - 643
  • [30] MONITORING OF CENTRAL VENOUS OXYGEN-SATURATION VERSUS MIXED VENOUS OXYGEN-SATURATION IN CRITICALLY ILL PATIENTS
    MARTIN, C
    AUFFRAY, JP
    BADETTI, C
    PERRIN, G
    PAPAZIAN, L
    GOUIN, F
    INTENSIVE CARE MEDICINE, 1992, 18 (02) : 101 - 104