A HIGH-PERFORMANCE PEAK-DETECT AND HOLD CIRCUIT FOR PULSE-HEIGHT ANALYSIS

被引:9
|
作者
BUCKENS, PF
VEATCH, MS
机构
[1] Kevex Instruments Inc., San Carlos, CA, 94070
关键词
3;
D O I
10.1109/23.159700
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Peak extractor circuits are an important link in most pulse-height analysis systems. Their performance will affect peak broadening, throughput, integral and differential linearity. A novel architecture is presented with performance exceeding previous state-of-the-art designs. A droop rate ranging from 125 muV/mus to 1 muV/mus and a charge injection of 5 mV are reported along with a 2.2 MHz bandwidth, a 38 V/mus slew rate and integral non-linearity of 50 ppm. The low droop rate allows temporary storage of the signal in an analog FIFO with minimal peak broadening, suitable for high resolution low energy x-ray analysis. This configuration has been implemented in an ADC system using the new Peak-Detect & Hold circuit architecture. The complete system has a differential linearity of 1.5% at 64K conversion gain, an integral linearity of +/- 0.016%, and an effective conversion time of 1.9 mus for a count rate of 210,000 c/s to the input of a pulse processor producing 3 mus-wide pulses.
引用
收藏
页码:753 / 757
页数:5
相关论文
共 50 条
  • [31] PULSE-HEIGHT ANALYSIS OF A LARGE COUNTER SYSTEM
    INYAKIN, AV
    JOHNSON, RP
    KRASNOKUTSKY, RN
    LEBEDEV, AA
    MIKHAILOV, YV
    PROKOSHKIN, YD
    SHUVALOV, RS
    NUCLEAR INSTRUMENTS & METHODS, 1974, 120 (03): : 385 - 387
  • [32] On the analysis of signal peaks in pulse-height spectra
    Rodgers, Cade R.
    Iliadis, Christian
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 998
  • [33] COMPUTER SYSTEM USED FOR PULSE-HEIGHT ANALYSIS
    SCHIMA, FJ
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1978, 28 : 36 - 36
  • [34] PULSE-HEIGHT ANALYSIS OF PARTIAL DISCHARGES IN AIR
    FLORKOWSKA, B
    WLODEK, R
    IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1993, 28 (06): : 932 - 940
  • [35] ANALYSIS OF SINGLE CRYSTAL PULSE-HEIGHT DISTRIBUTIONS
    CHILDERS, HM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1959, 30 (09): : 810 - 814
  • [36] AN ANALOG STORE AND MULTIPLEXER FOR PULSE-HEIGHT ANALYSIS
    ROBINSON, LB
    GIN, F
    CINGOLANI, H
    NUCLEAR INSTRUMENTS & METHODS, 1969, 75 (01): : 121 - +
  • [37] RADIATION SPECTROSCOPY BY DIGITAL PULSE-HEIGHT ANALYSIS
    ARCOS, JML
    GARCIATORANO, E
    OLMOS, P
    MARIN, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 251 - 253
  • [38] ON THE DESIGN OF FILTERS FOR PULSE-HEIGHT AND TIME ANALYSIS
    MELBERT, JG
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1982, 29 (01) : 614 - 618
  • [39] A Peak Detect and Hold Circuit Using Ramp Sampling Approach
    Lin, J. R.
    Chou, H. P.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 309 - 312
  • [40] Nanosecond Peak Detect and Hold Circuit With Adjustable Dynamic Range
    Fellner, Gabriel
    Speckbacher, Lucas
    Mousavi, Seyed Mostafa
    Pommerenke, David Johannes
    Shinde, Satyajeet
    Hillstrom, Michael
    Chundru, Ram
    Lam, Cheung-Wei
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72