SENSITIVITY ENHANCEMENT FOR CAPILLARY ELECTROPHORESIS

被引:143
|
作者
ALBIN, M
GROSSMAN, PD
MORING, SE
机构
[1] Applied Biosystems Division, Perkin-Elmer Corporation, Foster City, CA 94404
关键词
D O I
10.1021/ac00058a002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The relative gains achieved by using the different cell geometries and the chemical means discussed above are summarized in Tables II and III. Advantages and disadvantages of the different methods are indicated in terms of applicability, effects on the separation, and manufacturing concerns. Overall detection limits for the different modes are summarized in Table IV. Very low concentration detection limits can be obtained, and we believe they will become more available to the commercial instrument user as the application market develops. (Already two commercial LIF systems are available, and certainly the number and variety of detection configurations will expand.). © 1993, American Chemical Society. All rights reserved.
引用
收藏
页码:A489 / A497
页数:9
相关论文
共 50 条
  • [41] UV LONGITUDINAL CELL DESIGN WITH ENHANCED SENSITIVITY FOR CAPILLARY ELECTROPHORESIS
    ONUSKA, FI
    TERRY, KA
    JOURNAL OF MICROCOLUMN SEPARATIONS, 1993, 5 (03) : 255 - 260
  • [42] The More and Less Common Approaches to Enhancing Sensitivity in Capillary Electrophoresis
    Almeda, S.
    Arce, L.
    Valcarcel, M.
    CURRENT ANALYTICAL CHEMISTRY, 2010, 6 (02) : 126 - 143
  • [43] Applications of capillary electrophoresis to high-sensitivity analyses of biomolecules
    Terabe, S
    Monton, MRN
    Le Saux, T
    Imami, K
    PURE AND APPLIED CHEMISTRY, 2006, 78 (05) : 1057 - 1067
  • [46] SENSITIVITY ENHANCEMENT IN FLUORESCENCE CAPILLARY FIBER OPTIC SENSORS
    ZHU, ZY
    YAPPERT, MC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 201 : 195 - ANYL
  • [47] Higher Sensitivity of Capillary Electrophoresis in Detecting Hemoglobin A2′ Compared to Traditional Gel Electrophoresis
    Oleske, Deanna Alicia
    Huang, Richard Sheng Poe
    Dasgupta, Amitava
    Nguyen, Andy
    Wahed, Amer
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2014, 44 (03): : 291 - 293
  • [48] Sensitivity enhancement in capillary electrochromatography by on-column preconcentration
    Hilhorst, MJ
    Somsen, GW
    de Jong, GJ
    CHROMATOGRAPHIA, 2001, 53 (3-4) : 190 - 196
  • [49] Sensitivity enhancement in capillary electrochromatography by on-column preconcentration
    M. J. Hilhorst
    G. W. Somsen
    G. J. de Jong
    Chromatographia, 2000, 53 (3-4) : 190 - 196
  • [50] SENSITIVITY ENHANCEMENT IN FLUORESCENCE CAPILLARY/FIBER OPTIC SENSORS
    ZHU, ZY
    YAPPERT, MC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 77 - ANYL