HIGH-ACCURACY KERR EFFECT MEASUREMENT TECHNIQUE

被引:7
|
作者
SHELTON, DP
机构
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 1993年 / 64卷 / 04期
关键词
D O I
10.1063/1.1144144
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Apparatus and techniques are demonstrated which allow gas phase dc electro-optic Kerr effect measurements to be made with 0.1 % absolute accuracy and nanoradian sensitivity. Measurements of the electric-field-induced birefringence of a gas are calibrated against a liquid Kerr cell, which is in turn calibrated absolutely in situ. Some of the problems addressed in this work are control of stray birefringence in order to obtain an extinction ratio below 10(-10), a simple method for calibration of space charge effects in the CS2 reference Kerr cell, construction of electrodes with accurately calculable fields, and an investigation of the sources of systematic errors and drifts and means to eliminate them.
引用
收藏
页码:917 / 931
页数:15
相关论文
共 50 条
  • [21] High-accuracy measurement of radius using frequency-modulated technique for laser diode
    Thanh Tung Vu
    Cong Tuan Truong
    Toan Thang Vu
    Hong Hai Hoang
    INTERNATIONAL JOURNAL OF MODERN PHYSICS B, 2020, 34 (22-24):
  • [22] High-accuracy thickness measurement of a transparent plate with the heterodyne central fringe identification technique
    Wu, Wang-Tsung
    Hsieh, Hung-Chih
    Chang, Wei-Yao
    Chen, Yen-Liang
    Su, Der-Chin
    APPLIED OPTICS, 2011, 50 (21) : 4011 - 4016
  • [23] High-accuracy assigned power excitation for the FDTD technique
    Bellanca, G
    IEEE MICROWAVE AND GUIDED WAVE LETTERS, 1997, 7 (12): : 411 - 413
  • [24] DEVELOPMENT OF THE EXELFS TECHNIQUE FOR HIGH-ACCURACY STRUCTURAL INFORMATION
    QIAN, MX
    SARIKAYA, M
    STERN, EA
    ULTRAMICROSCOPY, 1995, 59 (1-4) : 137 - 147
  • [25] A high-accuracy digital readout technique for humidity sensor
    Shi, XJ
    Matsumoto, H
    Murao, K
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2001, 50 (05) : 1277 - 1282
  • [26] MolDock: A new technique for high-accuracy molecular docking
    Thomsen, Rene
    Christensen, Mikael H.
    JOURNAL OF MEDICINAL CHEMISTRY, 2006, 49 (11) : 3315 - 3321
  • [27] Development of numerical technique for advection with high-accuracy and resolution
    Asai, K
    ADVANCES IN HYDRAULICS AND WATER ENGINEERING, VOLS 1 AND 2, PROCEEDINGS, 2002, : 345 - 349
  • [28] SPARK EROSION TECHNIQUE FOR HIGH-ACCURACY METAL SPHERES
    MUIRHEAD, CM
    GREGORY, MN
    JONES, DW
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1976, 9 (10): : 812 - 814
  • [29] High-Accuracy and Fast Measurement of Optical Transfer Delay
    Li, Shupeng
    Qing, Ting
    Fu, Jianbin
    Wang, Xiangchuan
    Pan, Shilong
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [30] HIGH-ACCURACY SPECTROMETER FOR MEASUREMENT OF REGULAR SPECTRAL TRANSMITTANCE
    MANOOCHEHRI, F
    IKONEN, E
    APPLIED OPTICS, 1995, 34 (19): : 3686 - 3692