Minimally Invasive Plate Osteosynthesis with Locking Plates for Distal Tibia Fractures

被引:5
|
作者
Dhakar, Ajeet [1 ]
Annappa, Rajendra [2 ]
Gupta, Mahesh [1 ]
Harshwardhan, Hemeshwar [1 ]
Kotian, Prem [2 ]
Suresh, Pooja K. [3 ]
机构
[1] JLN Med Coll, Dept Orthopaed, Ajmer, Rajasthan, India
[2] Manipal Univ, Kasturba Med Coll, Dept Orthopaed, Mangalore 575001, Karnataka, India
[3] Manipal Univ, Kasturba Med Coll, Dept Pathol, Mangalore, Karnataka, India
关键词
Biological fixation; Distal tibia locking plates; MIPO for extraarticular fractures;
D O I
10.7860/JCDR/2016/15367.7332
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Distal tibia fractures are challenging injuries with multiple fixation options. Minimal invasive plating for distal tibia fracture is becoming more popular with documented good outcomes. Aim: To evaluate the functional and radiological results of fixation of distal tibia fractures with locking plates with Minimally Invasive Plate Osteosynthesis (MIPO) technique. Materials and Methods: Fifty fractures of distal tibia without Intra-articular extension were operated with locking compression plating with MIPO technique. They were followed up at regular intervals. Functional and radiological results were evaluated at the end on one year. Results: The fractures united in 48 (96%) patients with 2 (4%) cases of delayed union which took 30 weeks of time. Postoperatively, 2 patients developed superficial skin infection, 2 patients developed deep infection and 3 patients developed ankle stiffness due to loss of postoperative protocol and 4 patients had implant failure in form of screw breakage. Good amount of range of mobility of ankle joint was present in almost all patients. Conclusion: MIPO with locking plates for distal tibia fractures is associated with good functional outcomes and is an effective treatment for distal tibia fractures. Although, a larger sample of patients and longer follow up are required to fully evaluate this method of treatment, we strongly encourage its consideration in the treatment of such complex fractures.
引用
收藏
页码:RC1 / RC4
页数:4
相关论文
共 50 条
  • [41] Minimally Invasive Plate Osteosynthesis: Tibia and Fibula
    Beale, Brian S.
    McCally, Ryan
    VETERINARY CLINICS OF NORTH AMERICA-SMALL ANIMAL PRACTICE, 2012, 42 (05) : 1023 - +
  • [42] Distal Tibial Fractures Managed with Locking Compression Plate using Minimally Invasive Plate Osteosynthesis Technique: A Case Study
    Senthilkumar, M.
    Vanaj, P.
    Sujith, H.
    Anandan, Heber
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (08) : 43 - 47
  • [43] Distal tibia metaphyseal fractures: Which is better, intra-medullary nailing or minimally invasive plate osteosynthesis?
    Chandrakant, Kawalkar Abhijit
    Martand, Badole Chandrashekher
    JOURNAL OF ORTHOPAEDICS TRAUMA AND REHABILITATION, 2018, 24 : 66 - 71
  • [44] Malalignment after minimally invasive plate osteosynthesis in distal femoral fractures
    Kim, Joon-Woo
    Oh, Chang-Wug
    Oh, Jong-Keon
    Park, Il-Hyung
    Kyung, Hee-Soo
    Park, Kyeong-Hyeon
    Yoon, Seong-Dae
    Kim, Seong-Min
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2017, 48 (03): : 751 - 757
  • [45] A Dilemma in the Management of Distal Tibia Fractures Solved by Minimally Invasive Percutaneous Plate Osteosynthesis Technique: A Prospective Study
    Jeevo, Jerin
    Rajagopal, H. P.
    George, Akhshay J.
    Pilar, Anoop
    Muniswamy, Madan Mohan
    Kurian, Binu
    Basappa, Mallikarjunaswamy
    Amaravati, Rajkumar
    Adarsh, John
    Thomas, Merwin
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (06)
  • [46] Minimally invasive plate osteosynthesis using a locking compression plate for diaphyseal humeral fractures
    Malhan, Sachit
    Thomas, Simon
    Srivastav, Shekhar
    Agarwal, Shekhar
    Mittal, Vivek
    Nadkarni, Biren
    Gulati, Divesh
    JOURNAL OF ORTHOPAEDIC SURGERY, 2012, 20 (03) : 292 - 296
  • [47] Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures
    Oh, Chang-Wug
    Kim, Jung-Jae
    Byun, Young-Soo
    Oh, Jong-Keon
    Kim, Joon-Woo
    Kim, Shin-Yoon
    Park, Byung-Chul
    Lee, Hyun-Joo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (12) : 1659 - 1665
  • [48] Minimally invasive plate osteosynthesis of subtrochanteric femur fractures with a locking plate: a prospective series of 20 fractures
    Chang-Wug Oh
    Jung-Jae Kim
    Young-Soo Byun
    Jong-Keon Oh
    Joon-Woo Kim
    Shin-Yoon Kim
    Byung-Chul Park
    Hyun-Joo Lee
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 1659 - 1665
  • [49] Minimally Invasive Treatment of Distal Tibial Fractures with Locking and Non-Locking Plates
    Ozkaya, Ufuk
    Parmaksizoglu, Atilla S.
    Gul, Murat
    Sokucu, Sami
    Kabukcuoglu, Yavuz
    FOOT & ANKLE INTERNATIONAL, 2009, 30 (12) : 1161 - 1167
  • [50] Outcome of Locking Compression Plate in Supracondylar Fracture of Distal Femur by Minimally Invasive Plate Osteosynthesis
    Malik, Adnan Latif
    Siddique, Mudassar
    Niazi, Noman Shakeel
    Niazi, Suhail Niaz Khan
    PAKISTAN JOURNAL OF MEDICAL & HEALTH SCIENCES, 2015, 9 (01): : 31 - 33