BIOSENSOR BASED ON AN ENZYME-MODIFIED ELECTRODE FOR HIGHLY-SENSITIVE MEASUREMENT OF POLYPHENOLS

被引:31
|
作者
EREMENKO, A
MAKOWER, A
JIN, W
RUGER, P
SCHELLER, F
机构
[1] POTSDAM UNIV,DEPT ANALYT CHEM,D-13122 BERLIN,GERMANY
[2] RES CTR MOLEC DIAGNOST & THERAPY,DEPT BIOSENSORS,MOSCOW 113149,RUSSIA
[3] BOEHRINGER MANNHEIM GMBH,D-82377 PENZBERG,GERMANY
来源
BIOSENSORS & BIOELECTRONICS | 1995年 / 10卷 / 08期
关键词
AMPEROMETRY; ENZYME-MODIFIED ELECTRODE; POLYPHENOLS; P-AMINO-PHENOL;
D O I
10.1016/0956-5663(95)96962-X
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The use of glucose dehydrogenase from Acinetobacter calcoaceticus for highly sensitive measurement of polyphenols, based on bioelectrocatalytic analyte recycling, has been demonstrated. A polyphenol (analyte) is oxidized on the surface of a glassy carbon electrode at an anodic potential and is regenerated by immobilized glucose dehydrogenase (GDH) in the presence of glucose, resulting in an amplified response. The dynamic properties of the enzyme-modified glassy carbon electrode allow the convenient monitoring of subnanomolar analyte concentration. The detection limits for p-aminophenol and norepinephrine are 0.2 nM and 0.5 nM, respectively.
引用
收藏
页码:717 / 722
页数:6
相关论文
共 50 条
  • [21] Highly-sensitive cholesterol biosensor based on platinum-gold hybrid functionalized ZnO nanorods
    Wang, Chengyan
    Tan, Xingrong
    Chen, Shihong
    Yuan, Ruo
    Hu, Fangxin
    Yuan, Dehua
    Xiang, Yun
    TALANTA, 2012, 94 : 263 - 270
  • [22] Sensing based on the motion of enzyme-modified nanorods
    Bunea, Ada-Ioana
    Pavel, Ileana-Alexandra
    David, Sorin
    Gaspar, Szilveszter
    BIOSENSORS & BIOELECTRONICS, 2015, 67 : 42 - 48
  • [23] Highly-sensitive liquid crystal biosensor based on DNA dendrimers-mediated optical reorientation
    Tan, Hui
    Li, Xia
    Liao, Shuzhen
    Yu, Ruqin
    Wu, Zhaoyang
    BIOSENSORS & BIOELECTRONICS, 2014, 62 : 84 - 89
  • [24] Highly-sensitive and selective detection of hydrazine at gold electrode modified with PEG-coated CdS nanoparticles
    Khushboo
    Umar, Ahmad
    Kansal, Sushil K.
    Mehta, Surinder K.
    SENSORS AND ACTUATORS B-CHEMICAL, 2013, 188 : 372 - 377
  • [25] Enzyme-modified indium tin oxide microelectrode array-based electrochemical uric acid biosensor
    Puri, Nidhi
    Sharma, Vikash
    Tanwar, Vinod K.
    Singh, Nahar
    Biradar, Ashok M.
    Rajesh
    PROGRESS IN BIOMATERIALS, 2013, 2 (01)
  • [26] Highly sensitive choline biosensor based on nanotube modified pt electrode combined with sol-gel immobilization
    Song Zhao
    Huang Jiadong
    Shi Haibin
    Wu Baoyan
    Zhao Zixia
    Chen Qiang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (07) : 910 - 914
  • [27] Development of an enzyme-modified carbon paste electrode for determining inhibitors of lipoxygenase
    Rittmannsberger, A
    Likussar, W
    Michelitsch, A
    BIOSENSORS & BIOELECTRONICS, 2005, 21 (04): : 655 - 660
  • [28] Amperometric determination of urea using enzyme-modified carbon paste electrode
    Yang, JK
    Ha, KS
    Baek, HS
    Lee, SS
    Seo, ML
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2004, 25 (10) : 1499 - 1502
  • [29] Enzyme-modified indium tin oxide microelectrode array-based electrochemical uric acid biosensor
    Nidhi Puri
    Vikash Sharma
    Vinod K Tanwar
    Nahar Singh
    Ashok M Biradar
    Progress in Biomaterials, 2013, 2 (1)
  • [30] IGZO MESFET with enzyme-modified Schottky gate electrode for glucose sensing
    Kaczmarski, Jakub
    Jankowska-Sliwinska, Joanna
    Borysiewicz, Michal A.
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2019, 58 (09)