A THEORETICAL AND EXPERIMENTAL STUDY OF DIRECT-CONTACT CONDENSATION ON WATER IN TURBULENT FLOW

被引:0
|
作者
Celata, G. P. [1 ]
Cumo, M. [1 ]
D'Annibale, F. [1 ]
Farello, G. E. [1 ]
Focardi, G. [1 ]
机构
[1] ENEA CRE Casaccia TERM ISP Heat Transfer Lab, I-00060 Rome, Italy
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
The interaction between saturated or superheated steam in quasi-stagnant conditions and subcooled water in horizontal flow within a rectangular-duct test section has been experimentally investigated and the results are presented. A comparison between experimental results and predictions obtained using available correlations showed their inadequacy for a full description of the phenomenon. A laminar-turbulent mathematical model has been developed for the macroscopic description of the phenomenon and tested with the experimental data. The agreement is acceptable and well within the uncertainty band of the experimental measurements.
引用
收藏
页码:129 / 148
页数:20
相关论文
共 50 条
  • [31] EXPERIMENTAL DIRECT-CONTACT CRYSTALLIZER FOR MIRABILITE.
    Filippov, V.V.
    Karas'kov, G.G.
    Frolovskii, E.E.
    Belous, A.G.
    Nevshupa, O.I.
    Tishkin, V.I.
    Chemical and Petroleum Engineering, 1983, 19 (1-2) : 64 - 66
  • [32] Experimental study on an improved direct-contact thermal energy storage container
    He, Shiquan
    Chen, Zijun
    Wang, Weilong
    Chen, Qiliang
    Tang, Lan
    Huang, Yuantian
    JOURNAL OF ENERGY STORAGE, 2024, 102
  • [33] Experimental Study on Pressure Oscillations of Direct-Contact Condensation between Saturated Steam and Droplets at Sub-Atmospheric Pressure
    Jing, Yuanlin
    Wang, Chenhao
    Huang, Qunwu
    Wang, Yiping
    Yu, Yangyang
    PROCESSES, 2024, 12 (03)
  • [34] Comprehensive experimental and theoretical investigations on the effect of microbubble two-phase flow on the performance of direct-contact membrane distillation
    Kim, Yu-Bin
    Lee, Ho-Saeng
    Gil, Geon-Woo
    Ji, Ho
    Kim, Young-Deuk
    WATER RESEARCH, 2023, 229
  • [35] An experimental study of a three-phase, direct-contact heat exchanger
    Siqueiros, J
    Bonilla, O
    APPLIED THERMAL ENGINEERING, 1999, 19 (05) : 477 - 493
  • [36] BOILING OF WATER IN DIRECT-CONTACT VACUUM HEATERS
    EFIMOCHKIN, GI
    KRASHENNIKOV, VV
    VERBITSKII, VL
    THERMAL ENGINEERING, 1979, 26 (06) : 357 - 361
  • [37] Experiment study on steam-water direct contact condensation in water flow in a Tee junction
    Li, S. Q.
    Lu, T.
    Wang, L.
    Chen, H. S.
    APPLIED THERMAL ENGINEERING, 2017, 120 : 99 - 106
  • [38] Separation of volatile organic contaminants from water using a direct-contact dehumidifier: An experimental study and modeling
    Nikooei, Elnaz
    AuYeung, Nick
    Lima, Iolar
    Tan, Xu
    Benard, Andre
    Abbasi, Bahman
    JOURNAL OF WATER PROCESS ENGINEERING, 2023, 52
  • [39] Experimental investigation on interfacial oscillation of direct contact condensation of steam jet in water pipe flow
    Xu, Qiang
    Chu, Xiaona
    Yu, Haiyang
    Liu, Weizhi
    Yao, Tian
    Guo, Liejin
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 136 : 877 - 887
  • [40] DIRECT-CONTACT STEAM CONDENSATION WITH SIMULTANEOUS NONCONDENSABLE GAS-ABSORPTION
    BONTOZOGLOU, V
    KARABELAS, AJ
    AICHE JOURNAL, 1995, 41 (02) : 241 - 250